Two‐dimensional phase correction method for single and multi‐shot echo planar imaging
Author:
Open Access
- 13 May 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (6) , 1616-1626
Abstract
Ghost artifacts are a serious issue in single and multi‐shot echo planar imaging. Because of these coherent artifacts, it is essential to consistently suppress the ghosts. In this article, we present a phase correction algorithm that achieves excellent ghost suppression for single and multi‐shot echo planar imaging. The phase correction is performed along both the x (read) direction and y (phase) direction. To this end, we apply a double field of view prescan and compute the phase required for ghost suppression. This phase is fitted to a 2D polynomial. The fitted phase is used to correct the echo planar imaging images. The correction algorithm can be used with any readout gradient polarities and any number of shots. A flow chart of the correction method is provided to better clarify the full process. Finally, phantom and volunteer images demonstrate the improvement of artifact suppression obtained with this algorithm over conventional phase correction methods. Magn Reson Med, 2011.Keywords
This publication has 18 references indexed in Scilit:
- Robust 2D phase correction for echo planar imaging under a tight field‐of‐viewMagnetic Resonance in Medicine, 2010
- Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPAMagnetic Resonance in Medicine, 2010
- High resolution diffusion‐weighted imaging using readout‐segmented echo‐planar imaging, parallel imaging and a two‐dimensional navigator‐based reacquisitionMagnetic Resonance in Medicine, 2009
- Automatic correction of echo‐planar imaging (EPI) ghosting artifacts in real‐time interactive cardiac MRI using sensitivity encodingJournal of Magnetic Resonance Imaging, 2007
- A Method of Generalized Projections (MGP) Ghost Correction Algorithm for Interleaved EPIIEEE Transactions on Medical Imaging, 2004
- Removal of EPI Nyquist ghost artifacts with two‐dimensional phase correctionMagnetic Resonance in Medicine, 2004
- Two-dimensional deghosting for EPIMagnetic Resonance Materials in Physics, Biology and Medicine, 1999
- Echo-Planar Imaging Image Artifacts1998
- Image reconstruction for echo planar imaging with nonequidistant k‐space samplingMagnetic Resonance in Medicine, 1992
- Multi-planar image formation using NMR spin echoesJournal of Physics C: Solid State Physics, 1977