Abstract
In this study, we evaluate a phosphorus-based fire retardant (HR Prof) on Norway spruce using Simultaneous Thermal Analysis (STA: TG/DTG/DSC), Gas Chromatography–Mass Spectrometry (GC–MS), and bench-scale mass-loss measurements. Relative to the untreated reference, HR Prof re-routes decomposition toward earlier dehydration and transient char, simplifies the evolved gas mixture in the 150–250 °C range, and reduces burning intensity during 600 s of radiant exposure. Across 150/200/250 °C, identified components fell from 20/24/51 (reference) to 5/9/9 (HR Prof); no phosphorus-containing volatiles were detected in this window. Mass-loss tests showed a lower average burning rate (0.107 vs. 0.156%·s−1) and a smaller cumulative loss at 600 s (64.2 ± 9.5% vs. 93.7 ± 2.1%; one-way ANOVA, p < 0.05 for percentage loss). STA was conducted in air; the transient char formed at an intermediate temperature is oxidized near ~600 °C, explaining the low final residue despite earlier charring. A count-based Poisson model corroborated the significant reduction in volatile component richness for HR Prof (p < 0.001). The cross-method correspondences—earlier condensed-phase dehydration/char → leaner volatile pool → lower and flatter burning-rate profiles—support a condensed-phase-dominated protection mechanism within the conditions studied.
Funding Information
  • Agentúra na Podporu Výskumu a Vývoja (APVV-22-0030)
  • Ministry of Education, Research, Development and Youth of the Slovak Republic (VEGA 1/0115/22)

This publication has 27 references indexed in Scilit: