Study of new practical ESR dosimeter based on carbonated hydroxyapatite and its dosimetric properties
Open Access
- 29 May 2018
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (5) , e0197953
Abstract
The development of new dosimeters with good dosimetric properties is important for quality control in radiation applications. A new practical electron spin resonance (ESR) dosimeter based on carbonated hydroxyapatite that simulated the composition and structure of tooth enamel was specially synthesized. The synthesized material was investigated by transmission electron microscope, X-ray diffraction, fourier transform infrared spectroscopy and X-ray photo electron spectroscopy to confirm to the main composition of carbonated hydroxyapatite with CO32- successfully doped into the crystal lattice through optimizing the synthesis process of C/P molar ratio, pH value dynamical adjustment, annealing temperature and time. The dosimetric properties were systematically investigated by ESR spectroscopy. The results indicated that the radiation induced signal had a good dose response within a relatively wide dose range. The dose response was linear in the dose range of 0–400 Gy with a correlation coefficient of 0.9999 and had dose accumulative effect in the experimental dose range of 0–100 Gy. In a wider dose range up to 30 kGy, the dose response also presented linear feature in double-logarithmic coordinate system with a correlation coefficient of 0.9970. The dose detection limit was about 0.34Gy with a given probability of 95% confidence level depending upon a rigid calculation algorithm. The signal was extremely stable in the observation time of 360 days with a variation coefficient of 3.8%. The radiation sensitivity of the material showed no remarkable variation against photon energy from 662 KeV to 1.25 MeV and dose rate from 0.86 Gy/min to 12.17 Gy/min. The material showed more sensitive in lower photon energy range below 662 keV, which hint additional calibration may need when using in special photon energy condition. The preliminary results suggested that this newly developed dosimeter was potential to become a practical dosimeter that would expand the application fields of ESR dosimetry.Keywords
Funding Information
- National Science Funds of China (31670862)
This publication has 22 references indexed in Scilit:
- The 4th international comparison on EPR dosimetry with tooth enamelRadiation Measurements, 2011
- Gamma-irradiated EPR response of nano-structure hydroxyapatite synthesised via hydrolysis methodRadiation Protection Dosimetry, 2011
- CO2 gas-activated sintering of carbonated hydroxyapatitesJournal of the European Ceramic Society, 2011
- CO−2 radicals in synthetic hydroxyapatitePhysics of the Solid State, 2008
- Evidence of annealing-induced transformation of radicals in irradiated tooth enamelRadiation Measurements, 2006
- FTIR and XRD evaluation of carbonated hydroxyapatite powders synthesized by wet methodsJournal of Molecular Structure, 2005
- Studies by thermally stimulated current (TSC) of hydroxy- and fluoro-carbonated apatites containing sodium ionsJournal of Physics: Condensed Matter, 2000
- Energy Dependence of EPR Signal in Synthetic and Biological Hydroxyapatite Irradiated with PhotonsRadiation Protection Dosimetry, 1999
- Structure refinements by the Rietveld method of partially substituted hydroxyapatite: Ca9Na0.5(PO4)4.5(CO3)1.5(OH)2Journal of Alloys and Compounds, 1999
- 31P and 1H powder ENDOR and molecular orbital study of a CO3 3? ion in X-irradiated carbonate containing hydroxyapatitesJournal of the Chemical Society, Faraday Transactions, 1994