Ke Wu
Ke Wu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Guofu Dong
Beijing Key Laboratory of Radiation Biology (No. BZ0325) and Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, 100850, China
7 shared publicationsJunwang Guo
Beijing Key Laboratory of Radiation Biology (No. BZ0325) and Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, 100850, China
7 shared publicationsJianbo Cong
Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
6 shared publicationsLei Ma
Beijing Key Laboratory of Radiation Biology (No. BZ0325) and Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, 100850, China
6 shared publications- Guoshan Yang
Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology, Beijing, P. R. China
3 shared publications Jierui Zou
Beijing Institute of Radiation Medicine, Beijing Key Laboratory of Radiation Biology (No. BZ0325), China
3 shared publications
Latest Publications
- 1 June 2021
- Published by Elsevier in Protein Expression and Purification
- Vol. 182, 105844
Functional expression and purification of recombinant full-length human ATG7 protein with HIV-1 Tat peptide in Escherichia coli
- 1 June 2021
- Published by Elsevier in Protein Expression and Purification
- Vol. 182, 105844
Functional expression and purification of recombinant full-length human ATG7 protein with HIV-1 Tat peptide in Escherichia coli
- 1 July 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 149, 123-129
A normalization method of the volume and geometry of tooth for X-band in vivo EPR dosimetry
- 1 July 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 149, 123-129
A normalization method of the volume and geometry of tooth for X-band in vivo EPR dosimetry
- 1 September 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 139, 86-90
Effect of the tooth surface water on the accuracy of dose reconstructions in the X-band in vivo EPR dosimetry
- 1 September 2018
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 139, 86-90
Effect of the tooth surface water on the accuracy of dose reconstructions in the X-band in vivo EPR dosimetry
- Open Access
- 29 May 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (5) , e0197953
Study of new practical ESR dosimeter based on carbonated hydroxyapatite and its dosimetric properties
The development of new dosimeters with good dosimetric properties is important for quality control in radiation applications. A new practical electron spin resonance (ESR) dosimeter based on carbonated hydroxyapatite that simulated the composition and structure of tooth enamel was specially synthesized. The synthesized material was investigated by transmission electron microscope, X-ray diffraction, fourier transform infrared spectroscopy and X-ray photo electron spectroscopy to confirm to the main composition of carbonated hydroxyapatite with CO32- successfully doped into the crystal lattice through optimizing the synthesis process of C/P molar ratio, pH value dynamical adjustment, annealing temperature and time. The dosimetric properties were systematically investigated by ESR spectroscopy. The results indicated that the radiation induced signal had a good dose response within a relatively wide dose range. The dose response was linear in the dose range of 0–400 Gy with a correlation coefficient of 0.9999 and had dose accumulative effect in the experimental dose range of 0–100 Gy. In a wider dose range up to 30 kGy, the dose response also presented linear feature in double-logarithmic coordinate system with a correlation coefficient of 0.9970. The dose detection limit was about 0.34Gy with a given probability of 95% confidence level depending upon a rigid calculation algorithm. The signal was extremely stable in the observation time of 360 days with a variation coefficient of 3.8%. The radiation sensitivity of the material showed no remarkable variation against photon energy from 662 KeV to 1.25 MeV and dose rate from 0.86 Gy/min to 12.17 Gy/min. The material showed more sensitive in lower photon energy range below 662 keV, which hint additional calibration may need when using in special photon energy condition. The preliminary results suggested that this newly developed dosimeter was potential to become a practical dosimeter that would expand the application fields of ESR dosimetry.
- 29 May 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (5) , e0197953
Open AccessStudy of new practical ESR dosimeter based on carbonated hydroxyapatite and its dosimetric properties
The development of new dosimeters with good dosimetric properties is important for quality control in radiation applications. A new practical electron spin resonance (ESR) dosimeter based on carbonated hydroxyapatite that simulated the composition and structure of tooth enamel was specially synthesized. The synthesized material was investigated by transmission electron microscope, X-ray diffraction, fourier transform infrared spectroscopy and X-ray photo electron spectroscopy to confirm to the main composition of carbonated hydroxyapatite with CO32- successfully doped into the crystal lattice through optimizing the synthesis process of C/P molar ratio, pH value dynamical adjustment, annealing temperature and time. The dosimetric properties were systematically investigated by ESR spectroscopy. The results indicated that the radiation induced signal had a good dose response within a relatively wide dose range. The dose response was linear in the dose range of 0–400 Gy with a correlation coefficient of 0.9999 and had dose accumulative effect in the experimental dose range of 0–100 Gy. In a wider dose range up to 30 kGy, the dose response also presented linear feature in double-logarithmic coordinate system with a correlation coefficient of 0.9970. The dose detection limit was about 0.34Gy with a given probability of 95% confidence level depending upon a rigid calculation algorithm. The signal was extremely stable in the observation time of 360 days with a variation coefficient of 3.8%. The radiation sensitivity of the material showed no remarkable variation against photon energy from 662 KeV to 1.25 MeV and dose rate from 0.86 Gy/min to 12.17 Gy/min. The material showed more sensitive in lower photon energy range below 662 keV, which hint additional calibration may need when using in special photon energy condition. The preliminary results suggested that this newly developed dosimeter was potential to become a practical dosimeter that would expand the application fields of ESR dosimetry.
- 29 July 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 172 (1-3) , 103-111
The Application and Distribution of Magnetic Field Modulation in the Detection Apertures of X-band EPR Cavities forIn VivoTooth Dosimetry
In vivo electron paramagnetic resonance tooth dosimetry could be a practical and ideal tool for quick mass triage of victims in the rescue following a disaster event involving irradiation radiation. Magnetic field modulation is an important issue to improve the sensitivity of X-band in vivo tooth dosimetry. We designed a couple of trapezoidal modulation coil sets fixed on the magnet poles that could be used to apply sufficient magnet field modulation into the detection aperture of the resonant cavity. Measurements of irradiated teeth with such coil sets demonstrated significant radiation-induced signals. The modulation generation efficiencies and magnetic field distributions in apertures with different cavity geometries were analytically calculated, simulated by a finite element method and evaluated by measurements of a free radical point sample to study the influences caused by the geometries of the apertures and other factors.
- 29 July 2016
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 172 (1-3) , 103-111
The Application and Distribution of Magnetic Field Modulation in the Detection Apertures of X-band EPR Cavities forIn VivoTooth Dosimetry
In vivo electron paramagnetic resonance tooth dosimetry could be a practical and ideal tool for quick mass triage of victims in the rescue following a disaster event involving irradiation radiation. Magnetic field modulation is an important issue to improve the sensitivity of X-band in vivo tooth dosimetry. We designed a couple of trapezoidal modulation coil sets fixed on the magnet poles that could be used to apply sufficient magnet field modulation into the detection aperture of the resonant cavity. Measurements of irradiated teeth with such coil sets demonstrated significant radiation-induced signals. The modulation generation efficiencies and magnetic field distributions in apertures with different cavity geometries were analytically calculated, simulated by a finite element method and evaluated by measurements of a free radical point sample to study the influences caused by the geometries of the apertures and other factors.
- 3 July 2015
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 46 (10) , 1099-1107
Comparison of Four X-Band TE111 Cavities for In Vivo ESR Tooth Dosimetry
- 3 July 2015
- Published by Springer Nature in Applied Magnetic Resonance
- Vol. 46 (10) , 1099-1107
Comparison of Four X-Band TE111 Cavities for In Vivo ESR Tooth Dosimetry
- Open Access
- 4 April 2015
- Published by China Science Publishing & Media Ltd. in Acta Biochimica et Biophysica Sinica
- Vol. 47 (5) , 342-348
Calibration ruler for CW-EPR distance measurement using diradical molecule of rigid structure
Many experimental factors and uncontrollable factors may introduce errors in the distance measurement by continuous wave electron paramagnetic resonance. To deal with this problem, several C60 nitroxide diradical adducts with rigid structure and definite molecular dimension were used as distance calibration rulers. Based on the improvement of distance calculation program via adding simulation programs of experimental spectra and dipolar broadening function, respectively, the distance calibration method was developed under different conditions such as different solvent, solution concentration, measuring temperature, and microwave power. As a result, stable distance calibration rulers were established within the range of 8–13 Å. The distance calibration effect was evaluated resulting in a corresponding distance measurement precision of 0.84 Å. The results suggested that the influence of non-dipolar spectral broadening factors could be overcome, and the established experimental and calculation methods were suitable to a wide range of situations. The developed method will ensure more accurate and objective distance measurement in biomacromolecular analysis.
- 4 April 2015
- Published by China Science Publishing & Media Ltd. in Acta Biochimica et Biophysica Sinica
- Vol. 47 (5) , 342-348
Open AccessCalibration ruler for CW-EPR distance measurement using diradical molecule of rigid structure
Many experimental factors and uncontrollable factors may introduce errors in the distance measurement by continuous wave electron paramagnetic resonance. To deal with this problem, several C60 nitroxide diradical adducts with rigid structure and definite molecular dimension were used as distance calibration rulers. Based on the improvement of distance calculation program via adding simulation programs of experimental spectra and dipolar broadening function, respectively, the distance calibration method was developed under different conditions such as different solvent, solution concentration, measuring temperature, and microwave power. As a result, stable distance calibration rulers were established within the range of 8–13 Å. The distance calibration effect was evaluated resulting in a corresponding distance measurement precision of 0.84 Å. The results suggested that the influence of non-dipolar spectral broadening factors could be overcome, and the established experimental and calculation methods were suitable to a wide range of situations. The developed method will ensure more accurate and objective distance measurement in biomacromolecular analysis.