Abstract
We demonstrate coating-free optoacoustic generation and focusing of ultrasound using a mechanically Q-switched (MQS) erbium-doped yttrium aluminum garnet (Er:YAG) source (~100 ns, ≤20 mJ) combined with a concave water interface that simultaneously serves as converter and acoustic lens. Axial, lateral, and focal-point measurements mapped the pressure field while varying beam diameter (2w = 5–15 mm) and pulse energy (E = 10–20 mJ). The maximum focal positive pressure (Pmax = 7 MPa) occurs at an intermediate diameter (~10 mm), whereas the tightest lateral/axial confinement and strongest spectral enhancement arise at larger diameters (14–15 mm) with fc = ~5 MHz and −6 dB bandwidth up to 7 MHz. Pressure increases nearly monotonically with energy. For equal fluence, larger diameters yield higher focal pressures due to greater focusing gain. Small beams (2w ≈ 5–7 mm) show shorter apparent time-of-flight (TOF) and waveform broadening, consistent with early shock-like emission from locally vaporizing region. These results provide practical rules for tuning amplitude, spectrum, and confinement, enabling sub-millimeter focusing for contamination-sensitive and therapeutic applications.
Funding Information
  • The Slovenian Research and Innovation Agency (J7-50094)
  • The Slovenian Research and Innovation Agency (P2-0392)
  • European Union–NextGenerationEU

This publication has 39 references indexed in Scilit: