Ladder‐Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA
Authors:
Open Access
- 16 July 2022
- journal article
- research article
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 2022 (1) , 7804015
Abstract
Objective. To evaluate the feasibility of reducing the injection velocity and volume of contrast agent according to BMI, and the effect of body weight (BW), body surface area(BSA), body mass index(BMI),and blood volume (BV) on aortic contrast enhancement when the voltage of third‐generation dual‐source CT is selected at 70 KV. Methods. A total of 280 patients selected at 70 KV were randomly divided into an experimental group and a control group. Each group was divided into 7 subgroups according to BMI ≤20, 20–21, 21‐22, 22‐23, 23‐24, 24‐25, and 25–26. The experimental group uses 2.3/2.4/2.5/2.6/2.7/2.8/2.9 ml/s injection speed with 350 mgI/ml contrast agents according to the subgroups; injection time was fixed at 10 s. In the control group, the fixed injection flow rate was 3.5 ml/s, time was 12 s with a total of 42 ml. Subjects in both groups were inspected to adaptive prospective ECG‐gating sequence scanning, and subjective and objective image quality of the two groups were compared using Student's t‐test. BMI, BSA, and BV were calculated from the patient’s body weight and height. We assess the relationship between aortic attenuation and BW, BMI, BV, and BSA using regression analysis or correlation analysis. Results. Significant differences exist in vascular enhancement between the two groups; SNR and CNR of objective image quality in the experimental group were lower than those in the control group (P < 0.05). Both groups had the same subjective image scores (P > 0.05). The number of vessels in the optimal enhancement range counts more in the experimental group than in the control group (χ2 value = 334.25, P < 0.05). In the control group, a weak to medium correlation was seen between vascular enhancement and BMI (r = −0.20), BW (r = −0.42), BSA (r = −0.46), and BV (r = −0.48) (P < 0.05 for all). Conclusions. Compared to BW, BSA, and BV, a weaker negative correlation exists between vascular enhancement and BMI when ATVS selects 70 KV. However, as a much easier way to operate, the stepped low flow and low‐contrast agent injection based on BMI was feasible, and the image quality was more homogenized than that of the control group.Keywords
This publication has 14 references indexed in Scilit:
- Low radiation dose in computed tomography: the role of iodineBritish Journal of Radiology, 2017
- Impact on Image Quality and Radiation Dose of Third-Generation Dual-Source Computed Tomography of the Coronary ArteriesThe American Journal of Cardiology, 2017
- Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3rd generation dual-source CTEuropean Radiology, 2016
- SCCT guidelines for the interpretation and reporting of coronary CT angiography: A report of the Society of Cardiovascular Computed Tomography Guidelines CommitteeJournal of Cardiovascular Computed Tomography, 2014
- The influence of body mass index and gender on coronary arterial attenuation with fixed iodine load per body weight at dual-source CT coronary angiographyActa Radiologica, 2012
- Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and ApproachesRadiology, 2010
- Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantomEuropean Journal of Radiology, 2010
- 64-MDCT Coronary Angiography: Phantom Study of Effects of Vascular Attenuation on Detection of Coronary StenosisAmerican Journal of Roentgenology, 2008
- Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and ObesityAmerican Journal of Roentgenology, 2008
- Prediction of blood volume in normal human adults.1962