ZZZhao-Huan Zhu

Zhao-Huan Zhu

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhao-Huan Zhu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ladder‐Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA

    by Shang Ge, Jian-Yao Zhu, Han Liu, Yuan Chen, Zhao-Huan Zhu

    Objective. To evaluate the feasibility of reducing the injection velocity and volume of contrast agent according to BMI, and the effect of body weight (BW), body surface area(BSA), body mass index(BMI),and blood volume (BV) on aortic contrast enhancement when the voltage of third‐generation dual‐source CT is selected at 70 KV. Methods. A total of 280 patients selected at 70 KV were randomly divided into an experimental group and a control group. Each group was divided into 7 subgroups according to BMI ≤20, 20–21, 21‐22, 22‐23, 23‐24, 24‐25, and 25–26. The experimental group uses 2.3/2.4/2.5/2.6/2.7/2.8/2.9 ml/s injection speed with 350 mgI/ml contrast agents according to the subgroups; injection time was fixed at 10 s. In the control group, the fixed injection flow rate was 3.5 ml/s, time was 12 s with a total of 42 ml. Subjects in both groups were inspected to adaptive prospective ECG‐gating sequence scanning, and subjective and objective image quality of the two groups were compared using Student's t‐test. BMI, BSA, and BV were calculated from the patient’s body weight and height. We assess the relationship between aortic attenuation and BW, BMI, BV, and BSA using regression analysis or correlation analysis. Results. Significant differences exist in vascular enhancement between the two groups; SNR and CNR of objective image quality in the experimental group were lower than those in the control group (P < 0.05). Both groups had the same subjective image scores (P > 0.05). The number of vessels in the optimal enhancement range counts more in the experimental group than in the control group (χ2 value = 334.25, P < 0.05). In the control group, a weak to medium correlation was seen between vascular enhancement and BMI (r = −0.20), BW (r = −0.42), BSA (r = −0.46), and BV (r = −0.48) (P < 0.05 for all). Conclusions. Compared to BW, BSA, and BV, a weaker negative correlation exists between vascular enhancement and BMI when ATVS selects 70 KV. However, as a much easier way to operate, the stepped low flow and low‐contrast agent injection based on BMI was feasible, and the image quality was more homogenized than that of the control group.


  • Two-Steps Coronary Artery Segmentation Algorithm Based on Improved Level Set Model in Combination with Weighted Shape-Prior Constraints

    by Shang Ge, Zhaofei Shi, Guangming Peng, Zhaohuan Zhu

    Due to the complex topological structure of the coronary artery and the uneven distribution of the contrast agent, the angiography images are inevitably blurred and has low contrast, which causes great difficulty in process of segmentation. For this problem, a two-steps segmentation algorithm based on Hessian matrix and level set is proposed in this paper. Firstly, potential blood vessels of coronary images are preliminary extracted via Hessian matrix eigenvalues feature vectors of the geometric features and the response function. Then a novel regularization and area constraint is introduced into the local data energy fitting functional. Finally, the precision of Coronary Artery image is obtained in the evolution of the level set function. Experiments show that our proposed algorithm has better performance to these comparison segmentation algorithms.