Comparison between ceramic-on-polyethylene versus metal-on-polyethylene prostheses in Total Hip Arthroplasties: a systematic review and meta-analysis
Authors:
- Ighor Alexander Zamuner SpirISIghor Alexander Zamuner Spir
- Adriano AnzaiAAAdriano Anzai
- Armelim UtinoAUArmelim Utino
- Haroldo KatayamaHKHaroldo Katayama
- Giuliano ToselloGTGiuliano Tosello
- Mary Martins NeryMNMary Martins Nery
- Mauricio AnhesiniMAMauricio Anhesini
- Oswaldo Silvestrini TiezziOTOswaldo Silvestrini Tiezzi
- Pericles OtaniPOPericles Otani
- Wanderley Marques BernardoWBWanderley Marques Bernardo
Open Access
- 5 December 2022
- journal article
- review article
- Published by FapUNIFESP (SciELO) in Revista da Associação Médica Brasileira
- Vol. 68 (12) , 1611-1618
Abstract
The Guidelines Project, an initiative of the Brazilian Medical Association, aims to combine information from the medical field to standardize how to conduct, and to assist in the reasoning and decision-making of doctors. The information provided by this project must be critically evaluated by the physician responsible for the conduct that will be adopted, depending on the conditions and the clinical condition of each patient.Keywords
This publication has 29 references indexed in Scilit:
- More than 50% reduction of wear in polyethylene liners with alumina heads compared to cobalt-chrome heads in hip replacementsActa Orthopaedica, 2013
- Second-generation Annealed Highly Cross-linked Polyethylene Exhibits Low WearClinical Orthopaedics and Related Research, 2012
- Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: A ten-year follow-up with radiostereometryInternational Orthopaedics, 2011
- A Prospective Randomised Study of Periprosthetic Femoral Bone Remodeling Using Four Different Bearings in Hybrid Total Hip ArthroplastyHIP International, 2011
- Wear and migration of highly cross‐linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: A randomized radiostereometric study of 150 patientsJournal of Orthopaedic Research, 2011
- Minimum Five-Year Follow-Up Wear Measurement of Longevity Highly Cross-Linked Polyethylene Cup Against Cobalt-Chromium or Zirconia HeadsThe Journal of Arthroplasty, 2010
- Clinical Results of the Wear Performance of Cross-Linked Polyethylene in Total Hip Arthroplasty: Prospective Randomized TrialThe Journal of Arthroplasty, 2009
- Differences in Highly Cross-Linked Polyethylene Wear Between Zirconia and Cobalt-Chromium Femoral Heads in Japanese PatientsThe Journal of Arthroplasty, 2009
- Zirconia versus Co-Cr Femoral Heads in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2006
- A comparison of polyethylene wear in hips with cobalt-chrome or zirconia headsThe Journal of Bone and Joint Surgery. British volume, 2001