A novel sieve plate hole pattern: effect on gas hold-up and flow regimes in a bubble column
Authors:
- 25 October 2019
- journal article
- research article
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 207 (12) , 1755-1768
Abstract
The effect of an innovative sieve plate orifice layout on the hydrodynamics of a cylindrical bubble column is investigated. The classical triangular layout is compared with a novel spiraled layout, using the same number and diameter of orifices. The experiments include two different column aspect ratios and two liquid phases of different coalescing nature. According to the holdup data, if the spiraled layout is used, the flow regimes evolve from a pseudo-homogeneous regime to a heterogeneous regime going through a transition regime, as the superficial gas velocity increases. When the triangular layout is used, the homogeneous regime is not detected and pure heterogeneous regime is obtained at all superficial gas velocities. When using the spiraled layout, the gas retention increases, resulting 24% higher in the homogeneous regime and 13% higher in the heterogeneous regime with respect to the gas retention obtained with the triangular layout. If bubble coalescence is modified by the addition of NaCl, the holdup increases for both layouts, but to a lower extent in the spiraled layout (10%) compared to the triangular layout (24%). The reason behind the reduction of coalescence and higher gas holdup values is the ability of the spiraled layout to produce bubbles that do not interact with each other during a longer path along the column.Keywords
This publication has 34 references indexed in Scilit:
- Two regime transitions to pseudo-homogeneous and heterogeneous bubble flow for various liquid viscositiesChemical Engineering and Processing - Process Intensification, 2010
- Effect of gas distributor on hydrodynamics in shallow bubble column reactorsThe Canadian Journal of Chemical Engineering, 2009
- Bubble column reactorsProcess Biochemistry, 2005
- Experimental study of gas‐induced liquid‐flow structures in bubble columnsAIChE Journal, 2001
- Influence of coalescence behaviour of the liquid and of gas sparging on hydrodynamics and bubble characteristics in a bubble columnChemical Engineering and Processing - Process Intensification, 1999
- The prediction of gas hold-up in bubble column reactors: Newtonian and non-newtonian fluidsThe Chemical Engineering Journal, 1992
- Optimum gas sparger design for bubble columns with a low height-to-diameter ratioThe Chemical Engineering Journal, 1986
- Bubble Size, Interfacial Area, and Liquid-Phase Mass Transfer Coefficient in Bubble ColumnsIndustrial & Engineering Chemistry Process Design and Development, 1974
- Gas Holdup and Volumetric Mass Transfer Coefficient in Bubble Columns. Effects of Liquid PropertiesIndustrial & Engineering Chemistry Process Design and Development, 1973
- Bubble Coalescence and Gas Transfer in Aqueous Electrolytic SolutionsIndustrial & Engineering Chemistry Fundamentals, 1971