M. Elena Diaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
M. Elena Diaz has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Ramon L. Cerro
Chemical and Materials Engineering, University of Alabama in Huntsville 2 , Huntsville, Alabama 35899, USA
3 shared publicationsJavier Fuentes
Process Systems Enterprise, 6th Floor East, 26-28 Hammersmith Grove, London W6 7HA, UK
2 shared publicationsMichael D. Savage
School of Physics and Astronomy, Leeds University, Leeds, LS2 9JT, UK
2 shared publications- Michael D. Savage
School of Physics and Astronomy, Leeds University, Leeds LS2 9JT, UK
2 shared publications - Ramon L. Cerro
Chemical and Materials Engineering, University of Alabama in Huntsville, Huntsville, AL, 35899, United States
2 shared publications Francisco J. Montes
Department of Chemical Engineering, University of Salamanca, Salamanca, Spain
1 shared publication
Latest Publications
- 1 October 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (10) , 103601
A general solution of dewetting flow with a moving contact line
A theoretical model of a moving contact line was developed for a dewetting flow created by removing a flat solid from a liquid. The model introduces the effect of molecular forces in the near vicinity of the moving contact line. The laminar flow representation is based on a combination of streamline functions defined in a molecular domain where molecular forces are predominant and in a macroscopic domain where viscous forces are predominant. The solution realistically displays the details of the viscous flow near the contact line and compares accurately with existing experimental data. The combined molecular-macroscopic solution resolves the hydrodynamic paradox created by a purely viscous model of this flow [Huh, C. and Scriven, L.E., “Hydrodynamic model of the steady movement of a solid/liquid/fluid contact line,” J. Colloid Interface Sci. 35, 85–101 (1971)] shown to be at odds with experimental data [Fuentes, J. and Cerro, R. L. “Flow patterns and interfacial velocities near a moving contact line,” Experiments in Fluids 38(4), 503–510 (2005)].
- 1 October 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (10) , 103601
A general solution of dewetting flow with a moving contact line
A theoretical model of a moving contact line was developed for a dewetting flow created by removing a flat solid from a liquid. The model introduces the effect of molecular forces in the near vicinity of the moving contact line. The laminar flow representation is based on a combination of streamline functions defined in a molecular domain where molecular forces are predominant and in a macroscopic domain where viscous forces are predominant. The solution realistically displays the details of the viscous flow near the contact line and compares accurately with existing experimental data. The combined molecular-macroscopic solution resolves the hydrodynamic paradox created by a purely viscous model of this flow [Huh, C. and Scriven, L.E., “Hydrodynamic model of the steady movement of a solid/liquid/fluid contact line,” J. Colloid Interface Sci. 35, 85–101 (1971)] shown to be at odds with experimental data [Fuentes, J. and Cerro, R. L. “Flow patterns and interfacial velocities near a moving contact line,” Experiments in Fluids 38(4), 503–510 (2005)].
- 25 October 2019
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 207 (12) , 1755-1768
A novel sieve plate hole pattern: effect on gas hold-up and flow regimes in a bubble column
The effect of an innovative sieve plate orifice layout on the hydrodynamics of a cylindrical bubble column is investigated. The classical triangular layout is compared with a novel spiraled layout, using the same number and diameter of orifices. The experiments include two different column aspect ratios and two liquid phases of different coalescing nature. According to the holdup data, if the spiraled layout is used, the flow regimes evolve from a pseudo-homogeneous regime to a heterogeneous regime going through a transition regime, as the superficial gas velocity increases. When the triangular layout is used, the homogeneous regime is not detected and pure heterogeneous regime is obtained at all superficial gas velocities. When using the spiraled layout, the gas retention increases, resulting 24% higher in the homogeneous regime and 13% higher in the heterogeneous regime with respect to the gas retention obtained with the triangular layout. If bubble coalescence is modified by the addition of NaCl, the holdup increases for both layouts, but to a lower extent in the spiraled layout (10%) compared to the triangular layout (24%). The reason behind the reduction of coalescence and higher gas holdup values is the ability of the spiraled layout to produce bubbles that do not interact with each other during a longer path along the column.
- 25 October 2019
- Published by Taylor & Francis in Chemical Engineering Communications
- Vol. 207 (12) , 1755-1768
A novel sieve plate hole pattern: effect on gas hold-up and flow regimes in a bubble column
The effect of an innovative sieve plate orifice layout on the hydrodynamics of a cylindrical bubble column is investigated. The classical triangular layout is compared with a novel spiraled layout, using the same number and diameter of orifices. The experiments include two different column aspect ratios and two liquid phases of different coalescing nature. According to the holdup data, if the spiraled layout is used, the flow regimes evolve from a pseudo-homogeneous regime to a heterogeneous regime going through a transition regime, as the superficial gas velocity increases. When the triangular layout is used, the homogeneous regime is not detected and pure heterogeneous regime is obtained at all superficial gas velocities. When using the spiraled layout, the gas retention increases, resulting 24% higher in the homogeneous regime and 13% higher in the heterogeneous regime with respect to the gas retention obtained with the triangular layout. If bubble coalescence is modified by the addition of NaCl, the holdup increases for both layouts, but to a lower extent in the spiraled layout (10%) compared to the triangular layout (24%). The reason behind the reduction of coalescence and higher gas holdup values is the ability of the spiraled layout to produce bubbles that do not interact with each other during a longer path along the column.
- 1 October 2017
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 503, 159-167
The effect of temperature on contact angles and wetting transitions for n -alkanes on PTFE
- 1 October 2017
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 503, 159-167
The effect of temperature on contact angles and wetting transitions for n -alkanes on PTFE
- 1 August 2016
- Published by American Physical Society (APS) in Physical Review E
- Vol. 94 (2) , 022801
Prediction of static contact angles on the basis of molecular forces and adsorption data
At a three-phase contact line, a liquid bulk phase is in contact with and coexists with a very thin layer of adsorbed molecules. This adsorbed film in the immediate vicinity of a liquid wedge modifies the balance of forces between the liquid and solid phases such that, when included in the balance of forces, a quantitative relationship emerges between the adsorbed film thickness and the static contact angle. This relationship permits the prediction of static contact angles from molecular forces and equilibrium adsorption data by means of quantities that are physically meaningful and measurable. For n-alkanes on polytetrafluoroethylene, for which there are experimental data available on adsorption and contact angles, our computations show remarkable agreement with the data. The results obtained are an improvement on previously published calculations—particularly for alkanes with a low number of carbon atoms, for which adsorption is significant.
- 1 August 2016
- Published by American Physical Society (APS) in Physical Review E
- Vol. 94 (2) , 022801
Prediction of static contact angles on the basis of molecular forces and adsorption data
At a three-phase contact line, a liquid bulk phase is in contact with and coexists with a very thin layer of adsorbed molecules. This adsorbed film in the immediate vicinity of a liquid wedge modifies the balance of forces between the liquid and solid phases such that, when included in the balance of forces, a quantitative relationship emerges between the adsorbed film thickness and the static contact angle. This relationship permits the prediction of static contact angles from molecular forces and equilibrium adsorption data by means of quantities that are physically meaningful and measurable. For n-alkanes on polytetrafluoroethylene, for which there are experimental data available on adsorption and contact angles, our computations show remarkable agreement with the data. The results obtained are an improvement on previously published calculations—particularly for alkanes with a low number of carbon atoms, for which adsorption is significant.
- 1 August 2010
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 348 (1) , 232-239
An analytical solution for a partially wetting puddle and the location of the static contact angle
- 1 August 2010
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 348 (1) , 232-239
An analytical solution for a partially wetting puddle and the location of the static contact angle
- 1 March 2010
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 343 (2) , 574-583
Hysteresis during contact angles measurement
- 1 March 2010
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 343 (2) , 574-583
Hysteresis during contact angles measurement