Dose perturbation in the presence of metallic implants: treatment planning system versus Monte Carlo simulations
Authors:
- Elinore WieslanderEWElinore Wieslander
- Tommy KnöösTKTommy Knöös
- 2 October 2003
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 48 (20) , 3295-3305
Abstract
An increasing number of patients receiving radiation therapy have metallic implants such as hip prostheses. Therefore, beams are normally set up to avoid irradiation through the implant; however, this cannot always be accomplished. In such situations, knowledge of the accuracy of the used treatment planning system (TPS) is required. Two algorithms, the pencil beam (PB) and the collapsed cone (CC), are implemented in the studied TPS. Comparisons are made with Monte Carlo simulations for 6 and 18 MV. The studied materials are steel, CoCrMo, Orthinox, TiAlV and Ti. Monte Carlo simulated depth dose curves and dose profiles are compared to CC and PB calculated data. The CC algorithm shows overall a better agreement with Monte Carlo than the PB algorithm. Thus, it is recommended to use the CC algorithm to get the most accurate dose calculation both for the planning target volume and for tissues adjacent to the implants when beams are set up to pass through implants.Keywords
This publication has 12 references indexed in Scilit:
- The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiationsApplied Radiation and Isotopes, 2002
- Evaluation of the EGSnrc Monte Carlo code for interface dosimetry near high-Z media exposed to kilovolt and 60Co photonsPhysics in Medicine & Biology, 2002
- How accurate is a CT-based dose calculation on a pencil beam TPS for a patient with a metallic prosthesis?Physics in Medicine & Biology, 2001
- Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulationsMedical Physics, 2000
- Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 versionMedical Physics, 2000
- A pencil beam model for photon dose calculationMedical Physics, 1992
- Planning of radiotherapy for patients with hip prosthesisInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991
- Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous mediaMedical Physics, 1989
- Effect of a femoral head prosthesis on megavoltage beam radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1988
- Presta: The parameter reduced electron-step transport algorithm for electron monte carlo transportNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1986