White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC‐80
- 20 June 2023
- journal article
- retracted article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 45 (5) , 691-699
Abstract
Introduction: The manual differential count has been recognized for its disadvantages, including large interobserver variability and labor intensiveness. In this light, automated digital cell morphology analyzers have been increasingly adopted in hematology laboratories for their robustness and convenience. This study aims to evaluate the white blood cell differential performance of the Mindray MC‐80, the new automated digital cell morphology analyzer.Methods: The cell identification performance of Mindray MC‐80 was evaluated for sensitivity and specificity using pre‐classification and post‐classification of each cell class. The method comparison study used manual differentials as the gold standard for calculating Pearson correlation, Passing‐Bablok regression, and Bland–Altman analysis. In addition, the precision study was performed and evaluated.Results: The precision was within the acceptable limit for all cell classes. Overall, the specificity of cell identification was higher than 95% for all cell classes. The sensitivity was greater for 95% for most cell classes, except for myelocytes (94.9%), metamyelocytes (90.9%), reactive lymphocytes (89.7%), and plasma cells (60%). Pre‐classification and post‐classification results correlated well with the manual differential results for all the cell types investigated. The regression coefficients were greater than 0.9 for most cell classes except for promyelocytes, metamyelocytes, basophils, and reactive lymphocytes.Conclusion: The performance of Mindray MC‐80 for white blood cell differentials is reliable and seems to be acceptable even in abnormal samples. However, the sensitivity is less than 95% for certain abnormal cell types, so the user should be aware of this limitation where such cells are suspected.Keywords
This publication has 23 references indexed in Scilit:
- Digital Image Analysis of Blood CellsClinics In Laboratory Medicine, 2015
- ICSH guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte countingInternational Journal of Laboratory Hematology, 2014
- Can automated blood film analysis replace the manual differential? An evaluation of the CellaVision DM96 automated image analysis systemInternational Journal of Laboratory Hematology, 2009
- Performance evaluation and relevance of the CellaVisionTM DM96 system in routine analysis and in patients with malignant hematological diseasesInternational Journal of Laboratory Hematology, 2008
- Between-examiner reproducibility in manual differential leukocyte countingAccreditation and Quality Assurance, 2007
- Examination of peripheral blood films using automated microscopy; evaluation of Diffmaster Octavia and Cellavision DM96Journal of Clinical Pathology, 2006
- Does the band cell survive the 21st century?European Journal of Haematology, 2006
- Performance Evaluation of the CellaVision DM96 SystemAmerican Journal of Clinical Pathology, 2005
- Diagnosis from the Blood SmearThe New England journal of medicine, 2005
- The use of digital ‘virtual slides’ in the quality assessment of haematological morphology: results of a pilot exercise involving UK NEQAS(H) participantsBritish Journal of Haematology, 2005