Karan Paisooksantivatana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karan Paisooksantivatana has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Narin Khongjaroensakun
Department of Pathology, Faculty of Medicine Ramathibodi Hospital Mahidol University Bangkok Thailand
3 shared publicationsNutdanai Chaothai
Department of Pathology, Faculty of Medicine Ramathibodi Hospital Mahidol University Bangkok Thailand
3 shared publicationsPawadee Chinudomwong
Department of Pathology, Faculty of Medicine Ramathibodi Hospital Mahidol University Ratchathewi Thailand
3 shared publicationsKatesaree Suriyachand
Department of Pathology, Faculty of Medicine Ramathibodi Hospital Mahidol University Bangkok Thailand
2 shared publicationsLaksika Chamchomdao
Department of Pathology, Faculty of Medicine Ramathibodi Hospital Mahidol University Bangkok Thailand
2 shared publicationsAleeyas Binyasing
Department of Pathology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
1 shared publication
Latest Publications
- 4 September 2026
- Published by Wiley in International Journal of Laboratory Hematology
Defining Reference Intervals of Emerging Extended Inflammatory Parameters ( EIP ) in a Population‐Based Study
Introduction: Extended inflammatory parameters (EIPs), including neutrophil reactivity intensity (NEUT‐RI), neutrophil granularity intensity (NEUT‐GI), reactive lymphocytes (RE‐LYMP), and antibody‐synthesizing lymphocytes (AS‐LYMP), provide a rapid assessment of leukocyte activation. These parameters show diagnostic and prognostic value in infections and inflammatory diseases. However, their clinical application remains limited by the lack of standardized reference intervals (RIs), particularly in Southeast Asian populations. This study established population‐based RIs for EIPs in healthy Thai adults. Methods: Reference intervals were established following CLSI EP28 ‐A3c guidelines. Healthy adults were included if they had no history of chronic disease, recent infection or inflammation, pregnancy, or medication use affecting white blood cells, and demonstrated normal CBC results without qualitative flags. Outliers were excluded using the Tukey method. Non‐parametric methods were applied to calculate RIs , and the Harris and Boyd method was used to evaluate the need for age‐ and sex‐specific partitioning. Results: Most EIPs did not require demographic partitioning. Reference intervals of NEUT‐GI ranged from 146.7 to 160.0 scatter intensity (SI) units, and NEUT‐RI ranged from 42.4 to 52.2 fluorescence intensity (FI) units. AS‐LYMP% ranged from 0.0% to 0.4%, while AS‐LYMP# ranged from 0.00 to 0.02 × 10 9 /L. However, RE‐LYMP% and RE‐LYMP# demonstrated significant sex‐related differences requiring sex‐specific RIs. Female RE‐LYMP% ranged from 0.20% to 1.10% and male values from 0.10% to 0.90%, while RE‐LYMP# ranged from 0.01 to 0.08 × 10 9 /L in females and 0.01 to 0.06 × 10 9 /L in males. Conclusion: Reference intervals for NEUT ‐ GI , NEUT ‐ RI , RE ‐ LYMP , and AS ‐ LYMP were established in healthy Thai adults. Most EIPs did not require demographic partitioning, whereas RE ‐ LYMP % and RE ‐ LYMP # required sex‐specific intervals.
- 4 September 2026
- Published by Wiley in International Journal of Laboratory Hematology
Defining Reference Intervals of Emerging Extended Inflammatory Parameters ( EIP ) in a Population‐Based Study
Introduction: Extended inflammatory parameters (EIPs), including neutrophil reactivity intensity (NEUT‐RI), neutrophil granularity intensity (NEUT‐GI), reactive lymphocytes (RE‐LYMP), and antibody‐synthesizing lymphocytes (AS‐LYMP), provide a rapid assessment of leukocyte activation. These parameters show diagnostic and prognostic value in infections and inflammatory diseases. However, their clinical application remains limited by the lack of standardized reference intervals (RIs), particularly in Southeast Asian populations. This study established population‐based RIs for EIPs in healthy Thai adults. Methods: Reference intervals were established following CLSI EP28 ‐A3c guidelines. Healthy adults were included if they had no history of chronic disease, recent infection or inflammation, pregnancy, or medication use affecting white blood cells, and demonstrated normal CBC results without qualitative flags. Outliers were excluded using the Tukey method. Non‐parametric methods were applied to calculate RIs , and the Harris and Boyd method was used to evaluate the need for age‐ and sex‐specific partitioning. Results: Most EIPs did not require demographic partitioning. Reference intervals of NEUT‐GI ranged from 146.7 to 160.0 scatter intensity (SI) units, and NEUT‐RI ranged from 42.4 to 52.2 fluorescence intensity (FI) units. AS‐LYMP% ranged from 0.0% to 0.4%, while AS‐LYMP# ranged from 0.00 to 0.02 × 10 9 /L. However, RE‐LYMP% and RE‐LYMP# demonstrated significant sex‐related differences requiring sex‐specific RIs. Female RE‐LYMP% ranged from 0.20% to 1.10% and male values from 0.10% to 0.90%, while RE‐LYMP# ranged from 0.01 to 0.08 × 10 9 /L in females and 0.01 to 0.06 × 10 9 /L in males. Conclusion: Reference intervals for NEUT ‐ GI , NEUT ‐ RI , RE ‐ LYMP , and AS ‐ LYMP were established in healthy Thai adults. Most EIPs did not require demographic partitioning, whereas RE ‐ LYMP % and RE ‐ LYMP # required sex‐specific intervals.
- 26 January 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (6) , 1432-1437
Utility of flow cytometric PAX5 protein detection for the diagnosis of B-cell acute lymphoblastic leukemia
Objectives: Accurate B-lineage assignment in acute leukemia is critical for therapeutic decisions. While nuclear expression of PAX5 protein (nPAX5) is a highly reliable marker for B-cell differentiation, its conventional assessment by time-consuming immunohistochemistry (IHC) is not ideal for rapid diagnosis. This study aimed to validate the utility of flow cytometric (FCM) detection of nPAX5 for the diagnosis of B-lymphoblastic leukemia (B-ALL), potentially enhancing diagnostic efficiency. Methods: A retrospective study was conducted, comparing nPAX5 expression by FCM and IHC in 125 bone marrow biopsies (57 B-ALL, 12 T-ALL, 56 AML). Further diagnostic performance analysis, using ROC analysis of the geometric mean fluorescence intensity ratio (Blast/Normal T-cell), was performed for nPAX5, cCD22, and cCD79a across a larger cohort of 538 acute leukemia cases (123 B-ALL, 29 T-ALL, 386 AML). Results: FCM and IHC for PAX5 expression showed 100 % concordance across the 125 cases (57/57 B-ALL positive; 0/12 T-ALL negative). The single PAX5-positive AML case harbored the t(8;21) translocation. ROC analysis demonstrated excellent diagnostic performance for both cCD79a (AUC 0.980) and nPAX5 (AUC 0.955). At optimal criteria, cCD79a achieved 100.00 % specificity and 91.06 % sensitivity. nPAX5 showed strong utility, matching the 91.06 % sensitivity with 89.45 % specificity (criterion >6.30). cCD22 exhibited moderate discriminatory power (AUC 0.807). Conclusions: Flow cytometric nuclear PAX5 (nPAX5) demonstrated 100 % agreement with IHC and exhibited excellent diagnostic accuracy (AUC 0.955, 91.06 % sensitivity). These compelling results validate nPAX5 as a reliable and powerful FCM marker, supporting its immediate adoption for rapid and efficient B-lineage assignment in acute leukemia diagnostics.
- 26 January 2026
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (6) , 1432-1437
Utility of flow cytometric PAX5 protein detection for the diagnosis of B-cell acute lymphoblastic leukemia
Objectives: Accurate B-lineage assignment in acute leukemia is critical for therapeutic decisions. While nuclear expression of PAX5 protein (nPAX5) is a highly reliable marker for B-cell differentiation, its conventional assessment by time-consuming immunohistochemistry (IHC) is not ideal for rapid diagnosis. This study aimed to validate the utility of flow cytometric (FCM) detection of nPAX5 for the diagnosis of B-lymphoblastic leukemia (B-ALL), potentially enhancing diagnostic efficiency. Methods: A retrospective study was conducted, comparing nPAX5 expression by FCM and IHC in 125 bone marrow biopsies (57 B-ALL, 12 T-ALL, 56 AML). Further diagnostic performance analysis, using ROC analysis of the geometric mean fluorescence intensity ratio (Blast/Normal T-cell), was performed for nPAX5, cCD22, and cCD79a across a larger cohort of 538 acute leukemia cases (123 B-ALL, 29 T-ALL, 386 AML). Results: FCM and IHC for PAX5 expression showed 100 % concordance across the 125 cases (57/57 B-ALL positive; 0/12 T-ALL negative). The single PAX5-positive AML case harbored the t(8;21) translocation. ROC analysis demonstrated excellent diagnostic performance for both cCD79a (AUC 0.980) and nPAX5 (AUC 0.955). At optimal criteria, cCD79a achieved 100.00 % specificity and 91.06 % sensitivity. nPAX5 showed strong utility, matching the 91.06 % sensitivity with 89.45 % specificity (criterion >6.30). cCD22 exhibited moderate discriminatory power (AUC 0.807). Conclusions: Flow cytometric nuclear PAX5 (nPAX5) demonstrated 100 % agreement with IHC and exhibited excellent diagnostic accuracy (AUC 0.955, 91.06 % sensitivity). These compelling results validate nPAX5 as a reliable and powerful FCM marker, supporting its immediate adoption for rapid and efficient B-lineage assignment in acute leukemia diagnostics.
- Open Access
- 22 April 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 46 (5) , 850-861
Immune reconstitution in children after haploidentical haematopoietic stem cell transplantation
Introduction: Immune reconstitution (IR) kinetics of paediatric patients underwent haploidentical haematopoietic stem cell transplantation (HSCT) with post‐transplant cyclophosphamide (PTCy) have not been extensively studied. We compared IR patterns of children receiving HSCT from haploidentical ( n = 92) and HLA‐matched donors ( n = 36), and analysed risk factors for viral infection in these patients. Methods: We prospectively measured lymphocyte subset numbers before HSCT and at 1, 3, 6 and 12 months after HSCT. Blood cytomegalovirus (CMV), Epstein–Barr virus, adenovirus, BK virus (BKV) and urine adenovirus and BKV viral loads were measured at designated time points. Results: The median numbers of total T and T helper cells at 1 month were significantly lower in the haploidentical group compared with the HLA‐matched group. Haploidentical HSCT recipients had significantly lower median numbers of several T cell subsets and B cells for 1 year after HSCT. The median NK cell count of the haploidentical group was lower at 1 month. BKV haemorrhagic cystitis, blood CMV and urine adenovirus reactivation were more frequently found in the haploidentical group. Post‐haploidentical HSCT patients receiving anti‐T lymphocyte globulin (ATG) had significantly lower median numbers of total T cells (at 1 month) and T helper cells (at 6 and 12 months) and higher rate of blood BKV reactivation compared with those without ATG. Conclusion: Paediatric patients who undergo haploidentical HSCT with PTCy are likely to have delayed IR and an increased risk of viral reactivation/infection compared with HLA‐matched HSCT. The addition of ATG to PTCy delayed T cell recovery and increased risk of BKV reactivation.
- 22 April 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 46 (5) , 850-861
Open AccessImmune reconstitution in children after haploidentical haematopoietic stem cell transplantation
Introduction: Immune reconstitution (IR) kinetics of paediatric patients underwent haploidentical haematopoietic stem cell transplantation (HSCT) with post‐transplant cyclophosphamide (PTCy) have not been extensively studied. We compared IR patterns of children receiving HSCT from haploidentical ( n = 92) and HLA‐matched donors ( n = 36), and analysed risk factors for viral infection in these patients. Methods: We prospectively measured lymphocyte subset numbers before HSCT and at 1, 3, 6 and 12 months after HSCT. Blood cytomegalovirus (CMV), Epstein–Barr virus, adenovirus, BK virus (BKV) and urine adenovirus and BKV viral loads were measured at designated time points. Results: The median numbers of total T and T helper cells at 1 month were significantly lower in the haploidentical group compared with the HLA‐matched group. Haploidentical HSCT recipients had significantly lower median numbers of several T cell subsets and B cells for 1 year after HSCT. The median NK cell count of the haploidentical group was lower at 1 month. BKV haemorrhagic cystitis, blood CMV and urine adenovirus reactivation were more frequently found in the haploidentical group. Post‐haploidentical HSCT patients receiving anti‐T lymphocyte globulin (ATG) had significantly lower median numbers of total T cells (at 1 month) and T helper cells (at 6 and 12 months) and higher rate of blood BKV reactivation compared with those without ATG. Conclusion: Paediatric patients who undergo haploidentical HSCT with PTCy are likely to have delayed IR and an increased risk of viral reactivation/infection compared with HLA‐matched HSCT. The addition of ATG to PTCy delayed T cell recovery and increased risk of BKV reactivation.
- Retracted
- 20 June 2023
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 45 (5) , 691-699
White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC‐80
Introduction: The manual differential count has been recognized for its disadvantages, including large interobserver variability and labor intensiveness. In this light, automated digital cell morphology analyzers have been increasingly adopted in hematology laboratories for their robustness and convenience. This study aims to evaluate the white blood cell differential performance of the Mindray MC‐80, the new automated digital cell morphology analyzer.Methods: The cell identification performance of Mindray MC‐80 was evaluated for sensitivity and specificity using pre‐classification and post‐classification of each cell class. The method comparison study used manual differentials as the gold standard for calculating Pearson correlation, Passing‐Bablok regression, and Bland–Altman analysis. In addition, the precision study was performed and evaluated.Results: The precision was within the acceptable limit for all cell classes. Overall, the specificity of cell identification was higher than 95% for all cell classes. The sensitivity was greater for 95% for most cell classes, except for myelocytes (94.9%), metamyelocytes (90.9%), reactive lymphocytes (89.7%), and plasma cells (60%). Pre‐classification and post‐classification results correlated well with the manual differential results for all the cell types investigated. The regression coefficients were greater than 0.9 for most cell classes except for promyelocytes, metamyelocytes, basophils, and reactive lymphocytes.Conclusion: The performance of Mindray MC‐80 for white blood cell differentials is reliable and seems to be acceptable even in abnormal samples. However, the sensitivity is less than 95% for certain abnormal cell types, so the user should be aware of this limitation where such cells are suspected.
- 20 June 2023
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 45 (5) , 691-699
RetractedWhite blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC‐80
Introduction: The manual differential count has been recognized for its disadvantages, including large interobserver variability and labor intensiveness. In this light, automated digital cell morphology analyzers have been increasingly adopted in hematology laboratories for their robustness and convenience. This study aims to evaluate the white blood cell differential performance of the Mindray MC‐80, the new automated digital cell morphology analyzer.Methods: The cell identification performance of Mindray MC‐80 was evaluated for sensitivity and specificity using pre‐classification and post‐classification of each cell class. The method comparison study used manual differentials as the gold standard for calculating Pearson correlation, Passing‐Bablok regression, and Bland–Altman analysis. In addition, the precision study was performed and evaluated.Results: The precision was within the acceptable limit for all cell classes. Overall, the specificity of cell identification was higher than 95% for all cell classes. The sensitivity was greater for 95% for most cell classes, except for myelocytes (94.9%), metamyelocytes (90.9%), reactive lymphocytes (89.7%), and plasma cells (60%). Pre‐classification and post‐classification results correlated well with the manual differential results for all the cell types investigated. The regression coefficients were greater than 0.9 for most cell classes except for promyelocytes, metamyelocytes, basophils, and reactive lymphocytes.Conclusion: The performance of Mindray MC‐80 for white blood cell differentials is reliable and seems to be acceptable even in abnormal samples. However, the sensitivity is less than 95% for certain abnormal cell types, so the user should be aware of this limitation where such cells are suspected.
- Retraction
- 18 November 2022
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 45 (2) , 260
Retracted: White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC‐80
White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC‐80, K. Paisooksantivatana; N. Khongjaroensakun; P. Chinudomwong; N. Chaothai; L. Chamchomdao; K. Suriyachand, International Journal of Laboratory Hematology, 10.1111/ijlh.13995 The above article, published online on 18 November 2022, in Wiley Online Library (wileyonlinelibrary.com), had been retracted by agreement between the authors, the journal's Editors‐in‐Chief, Giuseppe D'Onofrio and Ian Mackie, and John Wiley & Sons. The authors contacted the journal after publication to propose extensive changes to the data presented in the accepted article such that it would no longer reflect the version that was peer reviewed. As a result, this retraction has been undertaken.
- 18 November 2022
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 45 (2) , 260
RetractionRetracted: White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC‐80
White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC‐80, K. Paisooksantivatana; N. Khongjaroensakun; P. Chinudomwong; N. Chaothai; L. Chamchomdao; K. Suriyachand, International Journal of Laboratory Hematology, 10.1111/ijlh.13995 The above article, published online on 18 November 2022, in Wiley Online Library (wileyonlinelibrary.com), had been retracted by agreement between the authors, the journal's Editors‐in‐Chief, Giuseppe D'Onofrio and Ian Mackie, and John Wiley & Sons. The authors contacted the journal after publication to propose extensive changes to the data presented in the accepted article such that it would no longer reflect the version that was peer reviewed. As a result, this retraction has been undertaken.
- Open Access
- 8 February 2022
- Published by Elsevier in Pediatric Hematology Oncology Journal
- Vol. 7 (1) , 10-15
The diagnostic performance of platelet function analyzer-100 (PFA-100) in Thai children with mucocutaneous bleeding disorder
- 8 February 2022
- Published by Elsevier in Pediatric Hematology Oncology Journal
- Vol. 7 (1) , 10-15
Open AccessThe diagnostic performance of platelet function analyzer-100 (PFA-100) in Thai children with mucocutaneous bleeding disorder
- 8 July 2021
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 43 (6) , 1373-1378
Improving the efficiency of the autoverification workflow for nucleated red blood cell reporting in the hematology laboratory
Objective Although the microscopic manual count is considered the standard method for NRBC enumeration, modern hematology analyzers can perform this task automatically with reliable accuracy and efficiency. This study aims to evaluate the diagnostic performance of the Sysmex XN hematology analyzer and to construct the optimal workflow for accurate and efficient NRBC reporting. Methods Specimens containing different levels of NRBC were included. Analytical performance was evaluated via method comparison with flow cytometry (FCM) and manual count (MC). Clinical sensitivity was analyzed by ROC analysis using manual count as the standard method. Results Correlation study of %NRBC with FCM and MC demonstrated an r value of 0.925 (95% CI 0.905 to 0.942) and 0.990 (95% CI 0.987 to 0.992) with a mean difference of −0.8 (95%CI: −6.7 to +5.0) and +0.50 (95% CI: −6.7 to +7.7), respectively. When the automated NRBC count was equal to zero and >0.07 × 109/L, the false-negative rate and false-positive rate were 100%, respectively; hence, manual slide review could be omitted. A false-positive rate of 72.7% was noted in specimens containing NRBC count less than 0.07 × 109/L. Conclusion The Sysmex XN can help improve the efficiency of NRBC enumeration owing to its accuracy, rapidity, and automation. However, further studies are required to improve the accuracy of detection in specimens containing a very low level of NRBC.
- 8 July 2021
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 43 (6) , 1373-1378
Improving the efficiency of the autoverification workflow for nucleated red blood cell reporting in the hematology laboratory
Objective Although the microscopic manual count is considered the standard method for NRBC enumeration, modern hematology analyzers can perform this task automatically with reliable accuracy and efficiency. This study aims to evaluate the diagnostic performance of the Sysmex XN hematology analyzer and to construct the optimal workflow for accurate and efficient NRBC reporting. Methods Specimens containing different levels of NRBC were included. Analytical performance was evaluated via method comparison with flow cytometry (FCM) and manual count (MC). Clinical sensitivity was analyzed by ROC analysis using manual count as the standard method. Results Correlation study of %NRBC with FCM and MC demonstrated an r value of 0.925 (95% CI 0.905 to 0.942) and 0.990 (95% CI 0.987 to 0.992) with a mean difference of −0.8 (95%CI: −6.7 to +5.0) and +0.50 (95% CI: −6.7 to +7.7), respectively. When the automated NRBC count was equal to zero and >0.07 × 109/L, the false-negative rate and false-positive rate were 100%, respectively; hence, manual slide review could be omitted. A false-positive rate of 72.7% was noted in specimens containing NRBC count less than 0.07 × 109/L. Conclusion The Sysmex XN can help improve the efficiency of NRBC enumeration owing to its accuracy, rapidity, and automation. However, further studies are required to improve the accuracy of detection in specimens containing a very low level of NRBC.
- Open Access
- 11 February 2020
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 34 (6) , e23225
Diagnostic performance of reticulocyte hemoglobin equivalent in assessing the iron status
Background: Measurement of reticulocyte hemoglobin equivalent (RET‐He) is rapid, convenient, and cost‐effective. Yet, researches on its performance in diagnosing iron deficiency with concurrent inflammation are limited. Hence, this study investigated RET‐He value in various states, including inflammation, and evaluated its diagnostic performance in iron status assessment.Methods: Retrospectively, 953 clinical data and laboratory results—complete blood count, reticulocyte count, RET‐He, and serum ferritin—were reviewed. Patients on iron therapy were excluded. Iron status was defined by serum ferritin as the reference method. RET‐He among populations was investigated. Its diagnostic performance and optimal cutoff were determined by ROC analysis.Results: Three population groups were classified: healthy control, iron deficiency anemia (IDA), and non‐ID anemia. Significantly, RET‐He value in IDA was lower than that of healthy control, anemia of inflammation, and chronic kidney disease (P < .0001). Low RET‐He was also observed in IDA with concomitant inflammation despite normal‐to‐high serum ferritin levels. No significant difference was observed between RET‐He values in pure IDA and thalassemia (P = .57). ROC curve analysis revealed AUC of 0.876 (P < .0001) at cutoff 30 pg, by which IDA was discriminated with 74.2% sensitivity and 97.4% specificity. Applying cutoff ≤30 pg, IDA can be diagnosed with 96% sensitivity, 97.4% specificity, 80% PPV, and 99.6% NPV. Hence, RET‐He >30 pg signifies a non‐IDA state.Conclusion: In addition to convenience and cost‐effectiveness, RET‐He cutoff >30 pg can be potentially used to exclude IDA due to its excellent diagnostic sensitivity and specificity.
- 11 February 2020
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 34 (6) , e23225
Open AccessDiagnostic performance of reticulocyte hemoglobin equivalent in assessing the iron status
Background: Measurement of reticulocyte hemoglobin equivalent (RET‐He) is rapid, convenient, and cost‐effective. Yet, researches on its performance in diagnosing iron deficiency with concurrent inflammation are limited. Hence, this study investigated RET‐He value in various states, including inflammation, and evaluated its diagnostic performance in iron status assessment.Methods: Retrospectively, 953 clinical data and laboratory results—complete blood count, reticulocyte count, RET‐He, and serum ferritin—were reviewed. Patients on iron therapy were excluded. Iron status was defined by serum ferritin as the reference method. RET‐He among populations was investigated. Its diagnostic performance and optimal cutoff were determined by ROC analysis.Results: Three population groups were classified: healthy control, iron deficiency anemia (IDA), and non‐ID anemia. Significantly, RET‐He value in IDA was lower than that of healthy control, anemia of inflammation, and chronic kidney disease (P < .0001). Low RET‐He was also observed in IDA with concomitant inflammation despite normal‐to‐high serum ferritin levels. No significant difference was observed between RET‐He values in pure IDA and thalassemia (P = .57). ROC curve analysis revealed AUC of 0.876 (P < .0001) at cutoff 30 pg, by which IDA was discriminated with 74.2% sensitivity and 97.4% specificity. Applying cutoff ≤30 pg, IDA can be diagnosed with 96% sensitivity, 97.4% specificity, 80% PPV, and 99.6% NPV. Hence, RET‐He >30 pg signifies a non‐IDA state.Conclusion: In addition to convenience and cost‐effectiveness, RET‐He cutoff >30 pg can be potentially used to exclude IDA due to its excellent diagnostic sensitivity and specificity.
- Open Access
- 28 August 2019
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 40 (6) , 573-589
Efficient short-term expansion of human peripheral blood regulatory T cells for co-culture suppression assay
Regulatory T cells (Tregs) are a small population of CD4+ lymphocytes and play a key role as suppressors of the immune system, a role that can be identified by employing a co-culture suppression assay. Conventional protocol requires a long period of in vitro expansion of Treg numbers; hence, this study describes an establishment of a co-culture suppression assay using a short-term expansion of peripheral blood (PB) Tregs and autologous T cells (Tconvs) IL-2-pre-cultured in parallel for the same length of time, thereby obviating the need of freeze/thawed autologous Tconvs. Tregs and Tconvs were isolated from PB mononuclear cells employing magnetic bead-aided depletion of CD8+ cells followed by cell sorting of CD4+ CD25high+CD127low- (Treg) and CD4+ CD25-CD127+ (Tconv) cell populations. Following a 3-day co-cultivation period under optimized conditions, Treg suppression activity was monitored by comparing using flow cytometry the number of carboxyfluorescein succinimidyl ester-labeled Tconvs to that of Treg-minus control. The assay allowed significant differentiation between Treg suppression activity of patients with active rheumatoid arthritis and those in remission. This method should be more convenient and time-saving than the conventional Treg suppression assay in current use.
- 28 August 2019
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 40 (6) , 573-589
Open AccessEfficient short-term expansion of human peripheral blood regulatory T cells for co-culture suppression assay
Regulatory T cells (Tregs) are a small population of CD4+ lymphocytes and play a key role as suppressors of the immune system, a role that can be identified by employing a co-culture suppression assay. Conventional protocol requires a long period of in vitro expansion of Treg numbers; hence, this study describes an establishment of a co-culture suppression assay using a short-term expansion of peripheral blood (PB) Tregs and autologous T cells (Tconvs) IL-2-pre-cultured in parallel for the same length of time, thereby obviating the need of freeze/thawed autologous Tconvs. Tregs and Tconvs were isolated from PB mononuclear cells employing magnetic bead-aided depletion of CD8+ cells followed by cell sorting of CD4+ CD25high+CD127low- (Treg) and CD4+ CD25-CD127+ (Tconv) cell populations. Following a 3-day co-cultivation period under optimized conditions, Treg suppression activity was monitored by comparing using flow cytometry the number of carboxyfluorescein succinimidyl ester-labeled Tconvs to that of Treg-minus control. The assay allowed significant differentiation between Treg suppression activity of patients with active rheumatoid arthritis and those in remission. This method should be more convenient and time-saving than the conventional Treg suppression assay in current use.