Amperometric Biosensor Based on Glutamate Oxidase to Determine Ast Activity
Open Access
Abstract
This work presents the development of an amperometric biosensor for detecting aspartate aminotransferase (AST) activity in biological fluids using a platinum disk electrode as the working transducer. Optimal concentrations of substrates (aspartate, α-ketoglutarate) and the coenzyme (pyridoxal phosphate) were determined to ensure efficient biosensor operation. A semi-permeable poly-m-phenylenediamine membrane was applied to enhance selectivity against electroactive interferents. The biosensor demonstrated good stability (storage, continuous operation, and production reproducibility) and analytical performance (sensitivity 8.56 nA/min for 50 U/L AST, LOD 1 U/L, linear range 1–110 U/L). Testing with real samples showed a high correlation (R = 0.989) with spectrophotometric analysis, supporting its potential for further applications.Keywords
Funding Information
- National Research Foundation of Ukraine (2022.01/0043, #1290589)
- Simons Foundation (2022.01/0043, #1290589)
This publication has 23 references indexed in Scilit:
- Low-Cost Point-of-Care Monitoring of ALT and AST Is Promising for Faster Decision Making and Diagnosis of Acute Liver InjuryDiagnostics, 2023
- Self-template sacrifice and in situ oxidation of a constructed hollow MnO2 nanozymes for smartphone-assisted colorimetric detection of liver function biomarkersAnalytica Chimica Acta, 2023
- Bio-sample detection on paper-based devices with inkjet printer-sprayed reagentsTalanta, 2015
- Liver enzymes and risk of cardiovascular disease in the general population: A meta-analysis of prospective cohort studiesAtherosclerosis, 2014
- Upper limit of normal serum alanine and aspartate aminotransferase levels in KoreaJournal of Gastroenterology and Hepatology, 2013
- Pt/Au bimetallic hierarchical structure with micro/nano-array via photolithography and electrochemical synthesis: From design to GOT and GPT biosensorsTalanta, 2009
- An Electrochemical Biosensor Array for Rapid Detection of Alanine Aminotransferase and Aspartate AminotransferaseBioscience, Biotechnology, and Biochemistry, 2009
- Sequential measurement of aminotransferase activities by amperometric biosensorsBiosensors and Bioelectronics, 2007
- Determination of the activities of glutamic oxaloacetic transaminase and glutamic pyruvic transaminase in a microfluidic systemBiosensors and Bioelectronics, 2007
- Viral hepatitis-related acute liver failureAmerican Journal of Gastroenterology, 2003