Sergei V. Dzyadevych
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sergei V. Dzyadevych has a total of 414 co-authors. Here are the top co-authors by number of shared publications:
- Alexey P. Soldatkin
Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
59 shared publications - Oleksandr O. Soldatkin
Інститут молекулярної біології і генетики НАН України; Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського», Україна
35 shared publications - Burcu Akata
Middle East Technical University
27 shared publications - Ivan S. Kucherenko
Інститут молекулярної біології та генетики НАН України
25 shared publications - Anna V. El'SKaya
Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
18 shared publications N. Jaffrezic-Renault
University Claude Bernard Lyon 1, Institute of Analytical Sciences, UMR5280 CNRS/UCBL/ENS, 5 rue de la Doua, 69100 Villeurbanne, France
17 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 23 (3) , 25-36
OPTIMIZATION OF OPERATING CONDITIONS OF рH-SENSITIVE FIELD-CONTROLLER TRANSISTORS FOR FURTHER USE IN BIOSENSORS
Biosensors based on ion-selective field-effect transistors (ISFETs) are promising devices for rapid analysis, having high sensitivity, selectivity and the possibility of mass production. However, their wide application is limited by sensitivity to external factors. The work investigated the influence of storage conditions, thermal (thermal and infrared) and ultraviolet treatment on the characteristics of sensors based on pH-sensitive field-effect transistors (pH-FETs). The upper limit of the heat treatment temperature was obtained, the effects of the influence of storage conditions, UV and IR treatment on the parameters of the studied pH-FET sensors were determined. It was confirmed that IR irradiation is a safe method of thermal treatment of sensors. The features of the influence of UV irradiation on the physicochemical characteristics of sensors during their restoration were also established. The results obtained provide important data for optimizing the conditions of use of pH-FET sensors as a basis for creating biosensors, in particular, regarding thermal and UV treatment, as well as storage conditions of biosensors during their long-term use.
- 30 September 2026
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 23 (3) , 25-36
Open AccessOPTIMIZATION OF OPERATING CONDITIONS OF рH-SENSITIVE FIELD-CONTROLLER TRANSISTORS FOR FURTHER USE IN BIOSENSORS
Biosensors based on ion-selective field-effect transistors (ISFETs) are promising devices for rapid analysis, having high sensitivity, selectivity and the possibility of mass production. However, their wide application is limited by sensitivity to external factors. The work investigated the influence of storage conditions, thermal (thermal and infrared) and ultraviolet treatment on the characteristics of sensors based on pH-sensitive field-effect transistors (pH-FETs). The upper limit of the heat treatment temperature was obtained, the effects of the influence of storage conditions, UV and IR treatment on the parameters of the studied pH-FET sensors were determined. It was confirmed that IR irradiation is a safe method of thermal treatment of sensors. The features of the influence of UV irradiation on the physicochemical characteristics of sensors during their restoration were also established. The results obtained provide important data for optimizing the conditions of use of pH-FET sensors as a basis for creating biosensors, in particular, regarding thermal and UV treatment, as well as storage conditions of biosensors during their long-term use.
- Open Access
- 2 September 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (9) , 1047
Novel Conductometric Chemosensor Based on Methylenebis(Phosphonic Acid)-Modified Calixarene for L-Arginine Determination
This study reports the synthesis of a novel methylenebisphosphonic acid calix[4]arene derivative and its application as a receptor layer in a conductometric chemosensor for the highly sensitive detection of L-arginine. The synthesized calixarene contains two methylenebisphosphonic acid fragments at the upper rim of the macrocycle, which serve as recognition sites for L-arginine, and two 3-(methylthio)propoxy groups at the lower rim, which enable immobilization on the gold electrode surface. The sensor based on synthesized calixarene demonstrated a pronounced response to L-arginine, which can be attributed to the cooperative interaction of the protonated amino and guanidinium groups of L-arginine with the methylenebisphosphonic acid groups of the calixarene receptor. Density functional theory (DFT) calculations were employed to elucidate the molecular interactions underlying the recognition of L-arginine by the calixarene receptor. The developed chemosensor demonstrated a low limit of detection for L-arginine (5.6 µM); a wide linear range (up to 1000 μM); a short response time (≤80 s); and a high response reproducibility (RSD = 1.3%). The stability constants determined by HPLC depended on the nature of the amino acid and ranged from logKA = 4.26 for leucine to logKA = 4.52 for L-arginine. Compared with previously reported L-arginine sensors, the developed conductometric chemosensor exhibits a competitive detection limit, a wider linear detection range, and significantly improved response reproducibility. The proposed calixarene-based chemosensor enables simple, highly sensitive, enzyme-free conductometric detection of L-arginine over a broad concentration range in aqueous solutions.
- 2 September 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (9) , 1047
Open AccessNovel Conductometric Chemosensor Based on Methylenebis(Phosphonic Acid)-Modified Calixarene for L-Arginine Determination
This study reports the synthesis of a novel methylenebisphosphonic acid calix[4]arene derivative and its application as a receptor layer in a conductometric chemosensor for the highly sensitive detection of L-arginine. The synthesized calixarene contains two methylenebisphosphonic acid fragments at the upper rim of the macrocycle, which serve as recognition sites for L-arginine, and two 3-(methylthio)propoxy groups at the lower rim, which enable immobilization on the gold electrode surface. The sensor based on synthesized calixarene demonstrated a pronounced response to L-arginine, which can be attributed to the cooperative interaction of the protonated amino and guanidinium groups of L-arginine with the methylenebisphosphonic acid groups of the calixarene receptor. Density functional theory (DFT) calculations were employed to elucidate the molecular interactions underlying the recognition of L-arginine by the calixarene receptor. The developed chemosensor demonstrated a low limit of detection for L-arginine (5.6 µM); a wide linear range (up to 1000 μM); a short response time (≤80 s); and a high response reproducibility (RSD = 1.3%). The stability constants determined by HPLC depended on the nature of the amino acid and ranged from logKA = 4.26 for leucine to logKA = 4.52 for L-arginine. Compared with previously reported L-arginine sensors, the developed conductometric chemosensor exhibits a competitive detection limit, a wider linear detection range, and significantly improved response reproducibility. The proposed calixarene-based chemosensor enables simple, highly sensitive, enzyme-free conductometric detection of L-arginine over a broad concentration range in aqueous solutions.
- Open Access
- 30 June 2026
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 23 (2) , 36-51
DEVELOPMENT OF A MULTIENZYME BIOSENSOR SYSTEM FOR SIMULTANEOUS DETERMINATION OF ALANINE AMINOTRANSFERASE AND ASPARTATE AMINOTRANSFERASE ACTIVITY
This paper presents the development of an amperometric biosensor system for the simultaneous determination of alanine aminotransferase (ALT) and aspartate aminotransferase (AST) activity in biological fluids. The system consists of two enzymatic biosensors: a pyruvate oxidase-based sensor for determining ALT and a glutamate oxidase-based sensor for determining AST. The operating principle of the proposed system is based on a cascade of reactions. First, ALT and AST induce transamination to form pyruvate and glutamate. Next, they are oxidized by pyruvate oxidase and glutamate oxidase, respectively, to hydrogen peroxide. Then, the decomposition of hydrogen peroxide is recorded amperometrically at a platinum electrode at a potential of +0.6 V relative to Ag/ AgCl. Pyruvate oxidase was immobilized by incorporation into a PVA-SbQ photopolymer matrix, and glutamate oxidase by covalent cross-linking with glutaraldehyde. To increase selectivity, the surface of the platinum electrode was modified with a poly(meta-phenylenediamine) membrane. The linear range of the developed biosensor system is 1–500 U/L for ALT and 1–110 U/L for AST, with a detection limit of 1 U/L for both enzymes. The system’s sensitivity is 0.05 nA/min and 0.137 nA/min per 1 U/L of ALT and AST, respectively. The repeatability error of responses during operation is RSD = 2.9% (ALT) and 14.1% (AST). The study demonstrates that the proposed biosensor system allows for the determination of the activity of both analytes in a single biological sample, making it promising for portable clinical diagnostics, specifically for the rapid, selective determination of transaminase activity in biological fluids.
- 30 June 2026
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 23 (2) , 36-51
Open AccessDEVELOPMENT OF A MULTIENZYME BIOSENSOR SYSTEM FOR SIMULTANEOUS DETERMINATION OF ALANINE AMINOTRANSFERASE AND ASPARTATE AMINOTRANSFERASE ACTIVITY
This paper presents the development of an amperometric biosensor system for the simultaneous determination of alanine aminotransferase (ALT) and aspartate aminotransferase (AST) activity in biological fluids. The system consists of two enzymatic biosensors: a pyruvate oxidase-based sensor for determining ALT and a glutamate oxidase-based sensor for determining AST. The operating principle of the proposed system is based on a cascade of reactions. First, ALT and AST induce transamination to form pyruvate and glutamate. Next, they are oxidized by pyruvate oxidase and glutamate oxidase, respectively, to hydrogen peroxide. Then, the decomposition of hydrogen peroxide is recorded amperometrically at a platinum electrode at a potential of +0.6 V relative to Ag/ AgCl. Pyruvate oxidase was immobilized by incorporation into a PVA-SbQ photopolymer matrix, and glutamate oxidase by covalent cross-linking with glutaraldehyde. To increase selectivity, the surface of the platinum electrode was modified with a poly(meta-phenylenediamine) membrane. The linear range of the developed biosensor system is 1–500 U/L for ALT and 1–110 U/L for AST, with a detection limit of 1 U/L for both enzymes. The system’s sensitivity is 0.05 nA/min and 0.137 nA/min per 1 U/L of ALT and AST, respectively. The repeatability error of responses during operation is RSD = 2.9% (ALT) and 14.1% (AST). The study demonstrates that the proposed biosensor system allows for the determination of the activity of both analytes in a single biological sample, making it promising for portable clinical diagnostics, specifically for the rapid, selective determination of transaminase activity in biological fluids.
- Open Access
- 30 March 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (4) , 426
Development of a Highly Sensitive SPR Biosensor for BCR–ABL Gene Sequence Detection Using a Novel Gold Nanoparticle–Enhanced Sandwich Assay Format
SPR (surface plasmon resonance) biosensor–based analytical methods enable rapid, straightforward, and cost-effective detection of DNA oligonucleotides. However, the detection limits of currently available SPR biosensors for BCR–ABL gene oligonucleotides remain too high to reliably detect sub-nanomolar concentrations. This study presents a new signal-enhancement approach for SPR DNA biosensors based on a gold nanoparticle (AuNP) sandwich assay. In this work, we demonstrated that AuNP-modified oligonucleotides can serve as labels that significantly amplify the SPR biosensor response in a sandwich-type SPR DNA biosensor. The analytical characteristics of the developed AuNP-labeled biosensor for detection of BCR–ABL fusion gene oligonucleotides were studied. The AuNP-labeled biosensor exhibited a detection limit of 80 pM, which is significantly lower than that of a traditional label-free SPR biosensor (50 nM). The measurement error for BCR–ABL target detection was significantly lower with the AuNP-labeled biosensor than with the label-free SPR biosensor. The conditions of synthesis of AuNPs by citrate reduction of AuCl3 that allow the monodisperse size distribution and absence of AuNP aggregation were established as well. Based on the obtained data, we conclude that a sandwich assay employing AuNP-modified oligonucleotides as labels is a promising approach for the highly sensitive detection of genetic markers. The developed AuNP-labeled DNA biosensing approach can be adapted to enhance the signal in other DNA hybridization-based SPR biosensors.
- 30 March 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (4) , 426
Open AccessDevelopment of a Highly Sensitive SPR Biosensor for BCR–ABL Gene Sequence Detection Using a Novel Gold Nanoparticle–Enhanced Sandwich Assay Format
SPR (surface plasmon resonance) biosensor–based analytical methods enable rapid, straightforward, and cost-effective detection of DNA oligonucleotides. However, the detection limits of currently available SPR biosensors for BCR–ABL gene oligonucleotides remain too high to reliably detect sub-nanomolar concentrations. This study presents a new signal-enhancement approach for SPR DNA biosensors based on a gold nanoparticle (AuNP) sandwich assay. In this work, we demonstrated that AuNP-modified oligonucleotides can serve as labels that significantly amplify the SPR biosensor response in a sandwich-type SPR DNA biosensor. The analytical characteristics of the developed AuNP-labeled biosensor for detection of BCR–ABL fusion gene oligonucleotides were studied. The AuNP-labeled biosensor exhibited a detection limit of 80 pM, which is significantly lower than that of a traditional label-free SPR biosensor (50 nM). The measurement error for BCR–ABL target detection was significantly lower with the AuNP-labeled biosensor than with the label-free SPR biosensor. The conditions of synthesis of AuNPs by citrate reduction of AuCl3 that allow the monodisperse size distribution and absence of AuNP aggregation were established as well. Based on the obtained data, we conclude that a sandwich assay employing AuNP-modified oligonucleotides as labels is a promising approach for the highly sensitive detection of genetic markers. The developed AuNP-labeled DNA biosensing approach can be adapted to enhance the signal in other DNA hybridization-based SPR biosensors.
- Open Access
- 23 December 2025
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 22 (4) , 50-60
NEW CONDUCTOMETRIC BIOSENSOR BASED ON RECOMBINANT UREASE ADSORBED ON SILICALITE
This experimental work is devoted to the development of a new conductometric biosensor with improved analytical characteristics for the quantitative detection of urea. The bioselective element of the biosensor was manufactured by adsorption of recombinant urease on a conductometric transducer modified with a thin layer of nanoporous silicalite particles (d = 250 nm). During the development of the biosensor, the influence of solution parameters on its functioning was studied. Namely, the magnitude of the responses of the biosensor based on recombinant urease depending on the protein concentration in the analyzed solution was studied. It was checked how the responses of the proposed biosensor change at different ionic strength and buffer capacity of the analyzed solution. The developed biosensor had a number of important advantages, such as fast response, ease of use, no need to use toxic agents during fabrication, high signal reproducibility during continuous operation (RSD = 5%), extended linear range within 0.02–9 mM, and high operational stability for at least 19 days of storage. Accordingly, taking into account the good analytical parameters of the development, the high prospect of using the biosensor based on recombinant urease adsorbed on silicalite for medical diagnostics of urea concentration in complex multicomponent biological fluids was proven.
- 23 December 2025
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 22 (4) , 50-60
Open AccessNEW CONDUCTOMETRIC BIOSENSOR BASED ON RECOMBINANT UREASE ADSORBED ON SILICALITE
This experimental work is devoted to the development of a new conductometric biosensor with improved analytical characteristics for the quantitative detection of urea. The bioselective element of the biosensor was manufactured by adsorption of recombinant urease on a conductometric transducer modified with a thin layer of nanoporous silicalite particles (d = 250 nm). During the development of the biosensor, the influence of solution parameters on its functioning was studied. Namely, the magnitude of the responses of the biosensor based on recombinant urease depending on the protein concentration in the analyzed solution was studied. It was checked how the responses of the proposed biosensor change at different ionic strength and buffer capacity of the analyzed solution. The developed biosensor had a number of important advantages, such as fast response, ease of use, no need to use toxic agents during fabrication, high signal reproducibility during continuous operation (RSD = 5%), extended linear range within 0.02–9 mM, and high operational stability for at least 19 days of storage. Accordingly, taking into account the good analytical parameters of the development, the high prospect of using the biosensor based on recombinant urease adsorbed on silicalite for medical diagnostics of urea concentration in complex multicomponent biological fluids was proven.
- Open Access
- 15 October 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (10) , 1168
Development and Comparative Evaluation of Two Enzyme-Based Amperometric Biosensor Designs for Alanine Aminotransferase Determination in Biological Fluids
Alanine aminotransferase (ALT) is a key biomarker of liver function. Compared with conventional assays for ALT detection—which are expensive, time-consuming, labor-intensive, and require experienced personnel—biosensors represent a promising alternative, but it remains unclear which biorecognitive enzymatic configuration offers the best analytical performance for ALT detection. This study presents the development and comparative evaluation of two amperometric biosensors based on oxidase biorecognition elements: pyruvate oxidase (POx) and glutamate oxidase (GlOx). Enzymes were immobilized onto platinum electrodes under optimized conditions using entrapment for POx (pH 7.4, enzyme loading 1.62 U/µL, PVA-SbQ concentration 13.2%) and covalent crosslinking for GlOx (pH 6.5, enzyme loading 2.67%, glutaraldehyde concentration 0.3%). Analytical parameters were systematically assessed, including linear range (1–500 U/L for POx vs. 5–500 U/L for GlOx), limit of detection (1 U/L for both), and sensitivity (0.75 vs. 0.49 nA/min at 100 U/L). The POx-based biosensor demonstrated higher sensitivity and lower detection limits, whereas the GlOx-based biosensor exhibited greater stability in complex solutions and reduced assay costs due to a simpler working solution. Moreover, while the POx-based system is uniquely suited for ALT determination, the GlOx-based sensor can be affected by AST activity in samples but may also be adapted for targeted AST detection. Overall, the study highlights a trade-off between sensitivity, robustness, and versatility in ALT biosensor design, providing guidance for the rational development of clinically relevant devices.
- 15 October 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (10) , 1168
Open AccessDevelopment and Comparative Evaluation of Two Enzyme-Based Amperometric Biosensor Designs for Alanine Aminotransferase Determination in Biological Fluids
Alanine aminotransferase (ALT) is a key biomarker of liver function. Compared with conventional assays for ALT detection—which are expensive, time-consuming, labor-intensive, and require experienced personnel—biosensors represent a promising alternative, but it remains unclear which biorecognitive enzymatic configuration offers the best analytical performance for ALT detection. This study presents the development and comparative evaluation of two amperometric biosensors based on oxidase biorecognition elements: pyruvate oxidase (POx) and glutamate oxidase (GlOx). Enzymes were immobilized onto platinum electrodes under optimized conditions using entrapment for POx (pH 7.4, enzyme loading 1.62 U/µL, PVA-SbQ concentration 13.2%) and covalent crosslinking for GlOx (pH 6.5, enzyme loading 2.67%, glutaraldehyde concentration 0.3%). Analytical parameters were systematically assessed, including linear range (1–500 U/L for POx vs. 5–500 U/L for GlOx), limit of detection (1 U/L for both), and sensitivity (0.75 vs. 0.49 nA/min at 100 U/L). The POx-based biosensor demonstrated higher sensitivity and lower detection limits, whereas the GlOx-based biosensor exhibited greater stability in complex solutions and reduced assay costs due to a simpler working solution. Moreover, while the POx-based system is uniquely suited for ALT determination, the GlOx-based sensor can be affected by AST activity in samples but may also be adapted for targeted AST detection. Overall, the study highlights a trade-off between sensitivity, robustness, and versatility in ALT biosensor design, providing guidance for the rational development of clinically relevant devices.
- 7 October 2025
- Published by Wiley in Electroanalysis
- Vol. 37 (10)
Design and Optimization of Biosensor for Pyruvate Quantification
In this work, an amperometric pyruvate‐sensitive biosensor was developed and optimized. A platinum disk electrode was used as an amperometric transducer. The bioselective element of the biosensor is based on the pyruvate oxidase enzyme immobilized with PVA‐SbQ polymer by photopolymerization. The optimal immobilization conditions (enzyme and photopolymer concentrations, duration, and intensity of photopolymerization) were selected. The optimal concentrations of cofactors and cosubstrates (phosphate ions, thiamine pyrophosphate, and magnesium ions (Mg 2+ ) were chosen to ensure the best sensitivity of the developed biosensor to pyruvate. After optimizing the design of the bioselective element and the immobilization process, the reproducibility of the biosensor manufacturing procedure was investigated (RSD = 12.5%). To assess the prospects of the developed biosensor, its main analytical characteristics were analyzed. The linear range of the biosensor was from 10 to 500 μM pyruvate, and the sensitivity was 66 nA/mM. The minimum detection threshold was 1.57 μM pyruvate. The obtained data indicate the technical feasibility and prospects of using the developed biosensor for determining the concentration of pyruvate in real multicomponent biological samples.
- 7 October 2025
- Published by Wiley in Electroanalysis
- Vol. 37 (10)
Design and Optimization of Biosensor for Pyruvate Quantification
In this work, an amperometric pyruvate‐sensitive biosensor was developed and optimized. A platinum disk electrode was used as an amperometric transducer. The bioselective element of the biosensor is based on the pyruvate oxidase enzyme immobilized with PVA‐SbQ polymer by photopolymerization. The optimal immobilization conditions (enzyme and photopolymer concentrations, duration, and intensity of photopolymerization) were selected. The optimal concentrations of cofactors and cosubstrates (phosphate ions, thiamine pyrophosphate, and magnesium ions (Mg 2+ ) were chosen to ensure the best sensitivity of the developed biosensor to pyruvate. After optimizing the design of the bioselective element and the immobilization process, the reproducibility of the biosensor manufacturing procedure was investigated (RSD = 12.5%). To assess the prospects of the developed biosensor, its main analytical characteristics were analyzed. The linear range of the biosensor was from 10 to 500 μM pyruvate, and the sensitivity was 66 nA/mM. The minimum detection threshold was 1.57 μM pyruvate. The obtained data indicate the technical feasibility and prospects of using the developed biosensor for determining the concentration of pyruvate in real multicomponent biological samples.
- Open Access
- 25 September 2025
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 22 (3) , 48-57
DEVELOPMENT OF AN AMPEROMETRIC GLUTAMATE-SENSITIVE BIOSENSOR BASED ON GLUTAMATE OXIDASE ADSORBED ON SILICALITE
In the current work, a new design of an amperometric biosensor for highly sensitive and selective detection of glutamate was developed using an atypical method of immobilizing glutamate oxidase (GlOX) by adsorption onto silicalite nanoparticles. The procedure for manufacturing the biosensor was optimized, namely, the main parameters of the modification of amperometric platinum transducers with a layer of silicalite nanoparticles were determined, and the optimal conditions for GlOX adsorption on this layer were also selected. Biosensors based on GlOX adsorbed on silicalite demonstrated high sensitivity to low concentrations of glutamate. The linear detection range was from 2.5 μM to 450 μM, and the detection limit of glutamate was 1 μM. It was also shown in the work that the proposed biosensors are characterized by high reproducibility of responses during several hours of continuous operation (RSD up to 7%) and good operational stability for several days. After carrying out the entire complex of works on the development and optimization of a new glutamate-sensitive biosensor, it was found that sensors of this design with the declared analytical characteristics can be used to determine low concentrations of glutamate in real biological fluids.
- 25 September 2025
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 22 (3) , 48-57
Open AccessDEVELOPMENT OF AN AMPEROMETRIC GLUTAMATE-SENSITIVE BIOSENSOR BASED ON GLUTAMATE OXIDASE ADSORBED ON SILICALITE
In the current work, a new design of an amperometric biosensor for highly sensitive and selective detection of glutamate was developed using an atypical method of immobilizing glutamate oxidase (GlOX) by adsorption onto silicalite nanoparticles. The procedure for manufacturing the biosensor was optimized, namely, the main parameters of the modification of amperometric platinum transducers with a layer of silicalite nanoparticles were determined, and the optimal conditions for GlOX adsorption on this layer were also selected. Biosensors based on GlOX adsorbed on silicalite demonstrated high sensitivity to low concentrations of glutamate. The linear detection range was from 2.5 μM to 450 μM, and the detection limit of glutamate was 1 μM. It was also shown in the work that the proposed biosensors are characterized by high reproducibility of responses during several hours of continuous operation (RSD up to 7%) and good operational stability for several days. After carrying out the entire complex of works on the development and optimization of a new glutamate-sensitive biosensor, it was found that sensors of this design with the declared analytical characteristics can be used to determine low concentrations of glutamate in real biological fluids.
- Open Access
- 25 September 2025
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 22 (3) , 8-18
FEASIBILITY OF APPLICATION OF A POTENTIOMETRIC BIOSENSOR BASED ON CREATININE DEIMINASE FOR NON-INVASIVE CREATININE ANALYSIS
The paper investigates the possibility of application of potentiometric biosensor based on creatinine deiminase for non-invasive analysis of creatinine in urine, sweat and saliva. The effect on the signal of various substances that can potentially affect the biosensor response and are contained in the urine of healthy people or patients with kidney diseases has been studied. It was shown that the contribution of these components to the total signal is minimal and will not significantly affect the accuracy of biosensor measurements. The stability during storage of the biosensor was more than 120 days. The principle possibility of creatinine determination by using a biosensor based on creatinine deiminase in saliva and sweat was shown, while the lowest creatinine concentration that can be determined was 50 μM. The developed biosensor demonstrates certain advantages in determining creatinine concentration in urine samples compared to the traditional colorimetric Jaffe method, which requires expensive equipment and careful control of reaction parameters to reduce the influence of interfering substances, as well as a complex measurement procedure.
- 25 September 2025
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 22 (3) , 8-18
Open AccessFEASIBILITY OF APPLICATION OF A POTENTIOMETRIC BIOSENSOR BASED ON CREATININE DEIMINASE FOR NON-INVASIVE CREATININE ANALYSIS
The paper investigates the possibility of application of potentiometric biosensor based on creatinine deiminase for non-invasive analysis of creatinine in urine, sweat and saliva. The effect on the signal of various substances that can potentially affect the biosensor response and are contained in the urine of healthy people or patients with kidney diseases has been studied. It was shown that the contribution of these components to the total signal is minimal and will not significantly affect the accuracy of biosensor measurements. The stability during storage of the biosensor was more than 120 days. The principle possibility of creatinine determination by using a biosensor based on creatinine deiminase in saliva and sweat was shown, while the lowest creatinine concentration that can be determined was 50 μM. The developed biosensor demonstrates certain advantages in determining creatinine concentration in urine samples compared to the traditional colorimetric Jaffe method, which requires expensive equipment and careful control of reaction parameters to reduce the influence of interfering substances, as well as a complex measurement procedure.
- Open Access
- 25 September 2025
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 22 (3) , 38-47
NEW CREATININE-SENSITIVE BIOSENSOR BASED ON CREATININE DEIMINASE ADSORBED ON SILICALITE
The work describes the development and adaptation of a new creatinine-sensitive biosensor based on pH-sensitive field-effect transistors and immobilized creatinine deiminase adsorbed on silicalite-modified electrodes. In order to analyze the potential of the new biosensor, most of the analytical characteristics were analyzed in comparison with the biosensor based on the traditional enzyme immobilization method. Covalent crosslinking of creatinine deiminase in saturated glutaraldehyde vapors was used as a comparison method. It has been shown that adsorption on silicalite significantly improves the main analytical parameters of the biosensor, compared to the control method. Also in the work, the reproducibility of the signals of the proposed biosensor and its stability during storage using an optimized buffer composition with the addition of stabilizers and preservatives were investigated. The effect of different concentrations of sodium chloride and protein (as the most influential components of blood serum) on the performance of a new creatinine-sensitive biosensor was tested. The developed and adapted biosensor based on creatinine deiminase adsorbed on silicalite is effective for quantitative detection of creatinine in real biological samples of patients with renal failure, such as blood serum and dialysis fluid.
- 25 September 2025
- Published by Odesa I.I. Mechnikov National University in Sensor Electronics and Microsystem Technologies
- Vol. 22 (3) , 38-47
Open AccessNEW CREATININE-SENSITIVE BIOSENSOR BASED ON CREATININE DEIMINASE ADSORBED ON SILICALITE
The work describes the development and adaptation of a new creatinine-sensitive biosensor based on pH-sensitive field-effect transistors and immobilized creatinine deiminase adsorbed on silicalite-modified electrodes. In order to analyze the potential of the new biosensor, most of the analytical characteristics were analyzed in comparison with the biosensor based on the traditional enzyme immobilization method. Covalent crosslinking of creatinine deiminase in saturated glutaraldehyde vapors was used as a comparison method. It has been shown that adsorption on silicalite significantly improves the main analytical parameters of the biosensor, compared to the control method. Also in the work, the reproducibility of the signals of the proposed biosensor and its stability during storage using an optimized buffer composition with the addition of stabilizers and preservatives were investigated. The effect of different concentrations of sodium chloride and protein (as the most influential components of blood serum) on the performance of a new creatinine-sensitive biosensor was tested. The developed and adapted biosensor based on creatinine deiminase adsorbed on silicalite is effective for quantitative detection of creatinine in real biological samples of patients with renal failure, such as blood serum and dialysis fluid.