Signal artefacts in wearable-based biosignal acquisition in patients with ventricular assist devices: the SMART-VADCH trial
Open Access
- 14 January 2026
- journal article
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (2)
Abstract
Aims: Telemonitoring is increasingly used in cardiovascular care, yet data on the reliability of smartwatch-based biosignal acquisition in patients with advanced heart failure and LVAD support remain limited. This study evaluated the feasibility and accuracy of smartwatch-derived heart rate (HR), oxygen saturation (SpO2), and single-lead ECG measurements in this population. Methods and results: In this prospective, single-centre pilot study, patients without LVAD or with durable (HeartMate 3) or temporary (Impella 5.5) LVADs underwent parallel resting measurements using a consumer smartwatch and standard clinical. Measurements unsuccessful after three attempts were classified as failures. Thirty-eight patients were enrolled (15 heart failure, 15 durable LVAD, 8 temporary LVAD). In patients without LVAD, HR was feasible in all patients and accurate within a 5% tolerance in 93% (95% CI 70–99%). At least one interpretable ECG was obtained in all, although QRS duration met a 10% tolerance in 33%. SpO₂ was feasible and accurate in 93%. In LVAD, HR was feasible in all patients and accurate in 82%. ECG was technically successful in all. QRS complexes were distinguishable in 73% of durable and all temporary LVAD. SpO₂ feasibility was overall limited (36%), but higher in temporary than durable LVAD patients (63% vs. 20%), and accurate when successful. SpO₂ failure was observed in patients without aortic valve opening, with tachycardia >100 bpm, and with darkly pigmented skin. Conclusion: The evaluated wrist-worn smartwatch reliably provided HR and ECG measurements in advanced heart failure, including LVAD patients, whereas SpO₂ performance remains limited.Keywords
This publication has 10 references indexed in Scilit:
- An Adjustable Smart Ring to Monitor Pulse Rate and Peripheral Blood Oxygen SaturationAnnals of Biomedical Engineering, 2025
- Ventricular arrhythmia after left ventricular assist device implantation and suggestions for implantable cardioverter defibrillator settingsHeartRhythm Case Reports, 2024
- Accuracy and clinical relevance of the single-lead Apple Watch electrocardiogram to identify atrial fibrillationCardiovascular Digital Health Journal, 2022
- Harnessing Artificial Intelligence in Cardiac rehabilitation: a Systematic ReviewFuture Cardiology, 2021
- Smart wearable devices in cardiovascular care: where we are and how to move forwardNature Reviews Cardiology, 2021
- Large-Scale Assessment of a Smartwatch to Identify Atrial FibrillationThe New England journal of medicine, 2019
- A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical LocationsSensors, 2019
- Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse CohortJournal of Personalized Medicine, 2017
- Meta-Analysis of the Relation of Ventricular Arrhythmias to All-Cause Mortality After Implantation of a Left Ventricular Assist DeviceThe American Journal of Cardiology, 2015
- Pulse oximetryCritical Care, 2015