Luise Roehrich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luise Roehrich has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Volkmar Falk
Deutsches Herzzentrum der Charité, Charité University Medicine Berlin , Berlin
7 shared publications - Felix Schoenrath
Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC) , Berlin
6 shared publications - Evgenij V. Potapov
Deutsches Herzzentrum der Charité, Department of Cardiothoracic and Vascular Surgery , Augustenburger Platz 1, 13353 Berlin
5 shared publications - Isabell Anna Just
Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC) , Augustenburger Platz 1, Berlin 13353
4 shared publications Marcus Mueller
Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin , Augustenburger Platz 1, Berlin, 13353
4 shared publications- Christoph Starck
Deutsches Herzzentrum der Charité (DHZC), Department of Cardiothoracic and Vascular Surgery, Augustenburger Platz 1, 13353 Berlin, Germany
3 shared publications
Latest Publications
- Open Access
- 14 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (2)
Signal artefacts in wearable-based biosignal acquisition in patients with ventricular assist devices: the SMART-VADCH trial
Aims: Telemonitoring is increasingly used in cardiovascular care, yet data on the reliability of smartwatch-based biosignal acquisition in patients with advanced heart failure and LVAD support remain limited. This study evaluated the feasibility and accuracy of smartwatch-derived heart rate (HR), oxygen saturation (SpO2), and single-lead ECG measurements in this population. Methods and results: In this prospective, single-centre pilot study, patients without LVAD or with durable (HeartMate 3) or temporary (Impella 5.5) LVADs underwent parallel resting measurements using a consumer smartwatch and standard clinical. Measurements unsuccessful after three attempts were classified as failures. Thirty-eight patients were enrolled (15 heart failure, 15 durable LVAD, 8 temporary LVAD). In patients without LVAD, HR was feasible in all patients and accurate within a 5% tolerance in 93% (95% CI 70–99%). At least one interpretable ECG was obtained in all, although QRS duration met a 10% tolerance in 33%. SpO₂ was feasible and accurate in 93%. In LVAD, HR was feasible in all patients and accurate in 82%. ECG was technically successful in all. QRS complexes were distinguishable in 73% of durable and all temporary LVAD. SpO₂ feasibility was overall limited (36%), but higher in temporary than durable LVAD patients (63% vs. 20%), and accurate when successful. SpO₂ failure was observed in patients without aortic valve opening, with tachycardia >100 bpm, and with darkly pigmented skin. Conclusion: The evaluated wrist-worn smartwatch reliably provided HR and ECG measurements in advanced heart failure, including LVAD patients, whereas SpO₂ performance remains limited.
- 14 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (2)
Open AccessSignal artefacts in wearable-based biosignal acquisition in patients with ventricular assist devices: the SMART-VADCH trial
Aims: Telemonitoring is increasingly used in cardiovascular care, yet data on the reliability of smartwatch-based biosignal acquisition in patients with advanced heart failure and LVAD support remain limited. This study evaluated the feasibility and accuracy of smartwatch-derived heart rate (HR), oxygen saturation (SpO2), and single-lead ECG measurements in this population. Methods and results: In this prospective, single-centre pilot study, patients without LVAD or with durable (HeartMate 3) or temporary (Impella 5.5) LVADs underwent parallel resting measurements using a consumer smartwatch and standard clinical. Measurements unsuccessful after three attempts were classified as failures. Thirty-eight patients were enrolled (15 heart failure, 15 durable LVAD, 8 temporary LVAD). In patients without LVAD, HR was feasible in all patients and accurate within a 5% tolerance in 93% (95% CI 70–99%). At least one interpretable ECG was obtained in all, although QRS duration met a 10% tolerance in 33%. SpO₂ was feasible and accurate in 93%. In LVAD, HR was feasible in all patients and accurate in 82%. ECG was technically successful in all. QRS complexes were distinguishable in 73% of durable and all temporary LVAD. SpO₂ feasibility was overall limited (36%), but higher in temporary than durable LVAD patients (63% vs. 20%), and accurate when successful. SpO₂ failure was observed in patients without aortic valve opening, with tachycardia >100 bpm, and with darkly pigmented skin. Conclusion: The evaluated wrist-worn smartwatch reliably provided HR and ECG measurements in advanced heart failure, including LVAD patients, whereas SpO₂ performance remains limited.
- Open Access
- 1 October 2025
- Published by Springer Nature in Communications Medicine
- Vol. 5 (1) , 1-7
Surgical and transcatheter aortic valve replacement after orthotopic heart transplantation: a case series
Background: Aortic valve dysfunction is a rare but relevant long-term complication after orthotopic heart transplantation (HTX). Treatment options include surgical (SAVR) and transcatheter (TAVR) aortic valve replacement, but evidence is limited to the level of case reports. Methods: A total of 2054 patients underwent HTX between 1986 and 2023 at the Deutsches Herzzentrum der Charité, Berlin, Germany, 16 of them underwent aortic valve replacement (SAVR, N = 7; TAVR, N = 9) after HTX. In this case series we report on the outcomes of these 16 patients (age 29-73 years). Results: Isolated aortic valve regurgitation occurs in 5 (31%) patients (TAVR N = 1, SAVR N = 4), while 11 patients (69%) suffer from aortic valve stenosis. Severe pre-procedural heart failure is present in 38% of the patients. Thirty-day mortality is 0%, in-hospital mortality is N = 2 (22%) patients due to sepsis, both patients were severely decompensated prior to TAVR. An uneventful postoperative course occurs in 8 (50%) patients, the patient’s functional status improves in 12 (75%) cases. Conclusion: TAVR is the increasingly preferred treatment for aortic valve dysfunction after heart transplantation, but SAVR is a feasible alternative for individuals who are ineligible for TAVR. Further information is needed on the appropriate procedural timing in these high-risk patients.
- 1 October 2025
- Published by Springer Nature in Communications Medicine
- Vol. 5 (1) , 1-7
Open AccessSurgical and transcatheter aortic valve replacement after orthotopic heart transplantation: a case series
Background: Aortic valve dysfunction is a rare but relevant long-term complication after orthotopic heart transplantation (HTX). Treatment options include surgical (SAVR) and transcatheter (TAVR) aortic valve replacement, but evidence is limited to the level of case reports. Methods: A total of 2054 patients underwent HTX between 1986 and 2023 at the Deutsches Herzzentrum der Charité, Berlin, Germany, 16 of them underwent aortic valve replacement (SAVR, N = 7; TAVR, N = 9) after HTX. In this case series we report on the outcomes of these 16 patients (age 29-73 years). Results: Isolated aortic valve regurgitation occurs in 5 (31%) patients (TAVR N = 1, SAVR N = 4), while 11 patients (69%) suffer from aortic valve stenosis. Severe pre-procedural heart failure is present in 38% of the patients. Thirty-day mortality is 0%, in-hospital mortality is N = 2 (22%) patients due to sepsis, both patients were severely decompensated prior to TAVR. An uneventful postoperative course occurs in 8 (50%) patients, the patient’s functional status improves in 12 (75%) cases. Conclusion: TAVR is the increasingly preferred treatment for aortic valve dysfunction after heart transplantation, but SAVR is a feasible alternative for individuals who are ineligible for TAVR. Further information is needed on the appropriate procedural timing in these high-risk patients.
- Open Access
- 6 January 2022
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 9 (2) , 1038-1049
Comparison of Feasibility and Results of Frailty Assessment Methods Prior to Left Ventricular Assist Device Implantation
Aims Assessing frailty and sarcopenia is considered a valuable cornerstone of perioperative risk stratification in advanced heart failure patients. The lack of an international consensus on a diagnostic standard impedes its implementation in the clinical routine. This study aimed to compare the feasibility and prognostic impact of different assessment tools in patients undergoing continuous-flow left ventricular assist device (cf-LVAD) implantation. Methods and results We prospectively compared feasibility and prognostic values of six frailty/sarcopenia assessment methods in 94 patients prior to cf-LVAD implantation: bioelectrical impedance analysis (BIA), computed tomography (CT)-based measurement of two muscle areas/body surface area [erector spinae muscle (TMESA/BSA) and iliopsoas muscle (TPA/BSA)], physical performance tests [grip strength, 6 min walk test (6MWT)] and Rockwood Clinical Frailty Scale (RCFS). Six-month mortality and/or prolonged ventilation time >95 h was defined as the primary endpoint. BIA and CT showed full feasibility (100%); physical performance and RCFS was limited due to patients' clinical status (feasibility: 87% grip strength, 62% 6MWT, 88% RCFS). Phase angle derived by BIA showed the best results regarding the prognostic value for 6 month mortality and/or prolonged ventilation time >95 h (odds ratio (OR) 0.66 [95% confidence interval (CI): 0.46–0.92], P = 0.019; area under the curve (AUC) 0.65). It provided incremental value to the clinical risk assessment of EuroSCORE II: C-index of the combined model was 0.75 [95% CI; 0.651–0.848] compared with C-index of EuroSCORE II alone, which was 0.73 (95% CI: 0.633–0.835). Six-month survival was decreased in patients with reduced body cell mass derived by BIA or reduced muscle area in the CT scan compared with patients with normal values: body cell mass 65% (95% CI: 51.8–81.6%) vs. 83% (95% CI: 74.0–93.9%); P = 0.03, TMESA/BSA 65% (95% CI: 51.2–82.2%) vs. 82% (95% CI: 73.2–93.0%); P = 0.032 and TPA/BSA 66% (95% CI: 53.7–81.0%) vs. 85% (95% CI: 75.0–95.8%); P = 0.035. Conclusions Bioelectrical impedance analysis parameters and CT measurements were shown to be suitable to predict 6-month mortality and/or prolonged ventilation time >95 h in patients with advanced heart failure prior to cf-LVAD implantation. Phase angle had the best predictive capacity and sarcopenia diagnosed by reduced body cell mass in BIA or muscle area in CT was associated with a decreased 6 month survival.
- 6 January 2022
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 9 (2) , 1038-1049
Open AccessComparison of Feasibility and Results of Frailty Assessment Methods Prior to Left Ventricular Assist Device Implantation
Aims Assessing frailty and sarcopenia is considered a valuable cornerstone of perioperative risk stratification in advanced heart failure patients. The lack of an international consensus on a diagnostic standard impedes its implementation in the clinical routine. This study aimed to compare the feasibility and prognostic impact of different assessment tools in patients undergoing continuous-flow left ventricular assist device (cf-LVAD) implantation. Methods and results We prospectively compared feasibility and prognostic values of six frailty/sarcopenia assessment methods in 94 patients prior to cf-LVAD implantation: bioelectrical impedance analysis (BIA), computed tomography (CT)-based measurement of two muscle areas/body surface area [erector spinae muscle (TMESA/BSA) and iliopsoas muscle (TPA/BSA)], physical performance tests [grip strength, 6 min walk test (6MWT)] and Rockwood Clinical Frailty Scale (RCFS). Six-month mortality and/or prolonged ventilation time >95 h was defined as the primary endpoint. BIA and CT showed full feasibility (100%); physical performance and RCFS was limited due to patients' clinical status (feasibility: 87% grip strength, 62% 6MWT, 88% RCFS). Phase angle derived by BIA showed the best results regarding the prognostic value for 6 month mortality and/or prolonged ventilation time >95 h (odds ratio (OR) 0.66 [95% confidence interval (CI): 0.46–0.92], P = 0.019; area under the curve (AUC) 0.65). It provided incremental value to the clinical risk assessment of EuroSCORE II: C-index of the combined model was 0.75 [95% CI; 0.651–0.848] compared with C-index of EuroSCORE II alone, which was 0.73 (95% CI: 0.633–0.835). Six-month survival was decreased in patients with reduced body cell mass derived by BIA or reduced muscle area in the CT scan compared with patients with normal values: body cell mass 65% (95% CI: 51.8–81.6%) vs. 83% (95% CI: 74.0–93.9%); P = 0.03, TMESA/BSA 65% (95% CI: 51.2–82.2%) vs. 82% (95% CI: 73.2–93.0%); P = 0.032 and TPA/BSA 66% (95% CI: 53.7–81.0%) vs. 85% (95% CI: 75.0–95.8%); P = 0.035. Conclusions Bioelectrical impedance analysis parameters and CT measurements were shown to be suitable to predict 6-month mortality and/or prolonged ventilation time >95 h in patients with advanced heart failure prior to cf-LVAD implantation. Phase angle had the best predictive capacity and sarcopenia diagnosed by reduced body cell mass in BIA or muscle area in CT was associated with a decreased 6 month survival.
- 1 January 2022
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 70 (S 01) , S1-S61
Influence of Cf-VAD Implantation on the Frailty Status of Advanced Heart Failure Patients
Background: Frailty is a potential reversible state, which affects the prognosis of advanced heart failure patients. This study aimed to examine the influence of continuous-flow ventricular assist device (cf-VAD) implantation on frailty. Method: We evaluated frailty in 64 patients prior to and 6 months after surgery via bioelectrical impedance analysis (BIA), 6-minute-walk test (6MWT) and grip strength measurement. Results: Postoperative phase angle increased (4.25° [IQR 3.30, 5.03] to 5.00° [IQR 4.57, 5.90]; p < 0.001) with a mean difference of 0.8°. 34 (53%) patients had a postoperative phase angle within the normal range (≥5.0°), whereas preoperative only 18 (28%) patients had a normal phase angle. Further analysis showed a significant postoperative increase in body cell mass (28.45 kg [IQR 24.60, 34.55] to 30.60 kg [IQR 26.80, 35.23]; p = 0.008) with a mean increase of 2.28 kg, while body water decreased (51.70 L [IQR: 45.25, 57.37] to 47.55 L [IQR 42.88, 52.28]; p = 0.003). Physical performance improved, evaluated by grip strength (28.50 kg [IQR 19.00, 39.00] to 33.50 kg [IQR 24.00, 43.00]; p = 0.001) and walking distance (145.00 m [IQR 0.00, 322.75] to 382.50 m [IQR 270.75, 471.00]; p < 0.001) with a mean difference of 6.5 kg resp. 192 m. Conclusion: After cf-VAD implantation, frailty state represented by phase angle improved significantly. Further analysis of BIA parameters and physical performance confirmed that the increase of phase angle originated from increase in muscle mass and cardiac recompensation. Analysis of changes in frailty status after efficient heart failure treatment could help develop a frailty assessment, which is able to distinguish disease dependent from disease independent frailty. Early cf-VAD implantation might be able to reverse both frailty and heart failure. It should be further evaluated against stabilization of heart failure with medical therapy/short-term mechanical circulatory support in combination with prehabilitation efforts prior to cf-VAD implantation. Publication Date: 03 February 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 1 January 2022
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 70 (S 01) , S1-S61
Influence of Cf-VAD Implantation on the Frailty Status of Advanced Heart Failure Patients
Background: Frailty is a potential reversible state, which affects the prognosis of advanced heart failure patients. This study aimed to examine the influence of continuous-flow ventricular assist device (cf-VAD) implantation on frailty. Method: We evaluated frailty in 64 patients prior to and 6 months after surgery via bioelectrical impedance analysis (BIA), 6-minute-walk test (6MWT) and grip strength measurement. Results: Postoperative phase angle increased (4.25° [IQR 3.30, 5.03] to 5.00° [IQR 4.57, 5.90]; p < 0.001) with a mean difference of 0.8°. 34 (53%) patients had a postoperative phase angle within the normal range (≥5.0°), whereas preoperative only 18 (28%) patients had a normal phase angle. Further analysis showed a significant postoperative increase in body cell mass (28.45 kg [IQR 24.60, 34.55] to 30.60 kg [IQR 26.80, 35.23]; p = 0.008) with a mean increase of 2.28 kg, while body water decreased (51.70 L [IQR: 45.25, 57.37] to 47.55 L [IQR 42.88, 52.28]; p = 0.003). Physical performance improved, evaluated by grip strength (28.50 kg [IQR 19.00, 39.00] to 33.50 kg [IQR 24.00, 43.00]; p = 0.001) and walking distance (145.00 m [IQR 0.00, 322.75] to 382.50 m [IQR 270.75, 471.00]; p < 0.001) with a mean difference of 6.5 kg resp. 192 m. Conclusion: After cf-VAD implantation, frailty state represented by phase angle improved significantly. Further analysis of BIA parameters and physical performance confirmed that the increase of phase angle originated from increase in muscle mass and cardiac recompensation. Analysis of changes in frailty status after efficient heart failure treatment could help develop a frailty assessment, which is able to distinguish disease dependent from disease independent frailty. Early cf-VAD implantation might be able to reverse both frailty and heart failure. It should be further evaluated against stabilization of heart failure with medical therapy/short-term mechanical circulatory support in combination with prehabilitation efforts prior to cf-VAD implantation. Publication Date: 03 February 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 13 December 2021
- Published by Wiley in Artificial Organs
- Vol. 46 (5) , 908-921
Impact of left ventricular inspection employing cardiopulmonary bypass on outcome after implantation of left ventricular assist device
Background: Cardiopulmonary bypass (CPB) during left ventricular assist device (LVAD) implantation provides circulatory support and allows for safe inspection of the left ventricle (LV), whereas circulatory support by veno‐arterial extracorporeal life support (va‐ECLS) or off‐pump implantation may reduce postoperative bleeding and inflammatory response.Methods: Retrospective analysis of 616 consecutive adult patients who received an LVAD via median sternotomy between January 1, 2015 and December 31, 2019. All patients undergoing concomitant intracardiac procedures other than closure of persistent foramen ovale or atrial septal defect and redo surgeries were excluded from the analysis. The remaining patients (n = 222) were divided into two groups and 1:1 propensity score‐matched regarding preoperative parameters: patients who underwent LVAD implantation with LV inspection employing CPB (CPB group, n = 62) and without LV inspection on va‐ECLS or off‐pump (non‐CPB group, n = 62).Results: The groups were well balanced with regard to preoperative baseline characteristics (standard difference p = 0.031) during surgery and in the first 24 h afterwards. The median intensive care unit stay was longer in the CPB group (18 vs. 11 days, p = 0.021). The CPB group showed an absence of perioperative stroke and a smaller number of events per patient‐year for postoperative ischemic stroke (0.02 vs. 0.12, p = 0.003). 30‐day survival (87% vs. 87.1%) and 1‐year survival (80.3% vs. 74%) were similar in both groups (p = 0.78).Conclusion: Visual LV inspection on CPB may reduce the risk of postoperative ischemic stroke. Despite the negative effects of employing CPB in lieu of other intraoperative strategies, survival was similar in both groups.
- 13 December 2021
- Published by Wiley in Artificial Organs
- Vol. 46 (5) , 908-921
Open AccessImpact of left ventricular inspection employing cardiopulmonary bypass on outcome after implantation of left ventricular assist device
Background: Cardiopulmonary bypass (CPB) during left ventricular assist device (LVAD) implantation provides circulatory support and allows for safe inspection of the left ventricle (LV), whereas circulatory support by veno‐arterial extracorporeal life support (va‐ECLS) or off‐pump implantation may reduce postoperative bleeding and inflammatory response.Methods: Retrospective analysis of 616 consecutive adult patients who received an LVAD via median sternotomy between January 1, 2015 and December 31, 2019. All patients undergoing concomitant intracardiac procedures other than closure of persistent foramen ovale or atrial septal defect and redo surgeries were excluded from the analysis. The remaining patients (n = 222) were divided into two groups and 1:1 propensity score‐matched regarding preoperative parameters: patients who underwent LVAD implantation with LV inspection employing CPB (CPB group, n = 62) and without LV inspection on va‐ECLS or off‐pump (non‐CPB group, n = 62).Results: The groups were well balanced with regard to preoperative baseline characteristics (standard difference p = 0.031) during surgery and in the first 24 h afterwards. The median intensive care unit stay was longer in the CPB group (18 vs. 11 days, p = 0.021). The CPB group showed an absence of perioperative stroke and a smaller number of events per patient‐year for postoperative ischemic stroke (0.02 vs. 0.12, p = 0.003). 30‐day survival (87% vs. 87.1%) and 1‐year survival (80.3% vs. 74%) were similar in both groups (p = 0.78).Conclusion: Visual LV inspection on CPB may reduce the risk of postoperative ischemic stroke. Despite the negative effects of employing CPB in lieu of other intraoperative strategies, survival was similar in both groups.
- 1 December 2021
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 27 (12) , 1328-1336
Safety of Contemporary Heart Failure Therapy in Patients with Continuous-Flow Left Ventricular Assist Devices
- 1 December 2021
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 27 (12) , 1328-1336
Safety of Contemporary Heart Failure Therapy in Patients with Continuous-Flow Left Ventricular Assist Devices
- Open Access
- 18 October 2021
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 8
Impact of Muscle Mass as a Prognostic Factor for Failed Waiting Time Prior to Heart Transplantation
Objectives: Clinical deterioration during the waiting time impairs the prognosis of patients listed for heart transplantation. Reduced muscle mass increases the risk for mortality after cardiac surgery, but its impact on resilience against deterioration during the waiting time remains unclear.Methods: We retrospectively analyzed data from 93 patients without a VAD who were listed in Eurotransplant status “high urgent (HU)” for heart transplantation between January 2015 and October 2020. The axial muscle area of the erector spinae muscles at the level of thoracic vertebra 12 indexed to body surface area (TMESA/BSA) measured in the preoperative thoracic computed tomography scan was used to measure muscle mass.Results: Forty patients (43%) underwent emergency VAD implantation during the waiting time and four patients (4%) died during the waiting time. The risk of emergency VAD implantation/death during the waiting time decreased by 10% for every cm2/m2 increase in muscle area [OR 0.901 (95% CI: 0.808–0.996); p = 0.049]. After adjusting for gender [OR 0.318 (95% CI: 0.087–1.073); p = 0.072], mean pulmonary artery pressure [OR 1.061 (95% CI: 0.999–1.131); p = 0.060], C-reactive protein [OR 1.352 (95% CI: 0.986–2.027); p = 0.096], and hemoglobin [OR 0.862 (95% CI: 0.618–1.177); p = 0.360], TMESA/BSA [OR 0.815 (95% CI: 0.698–0.936); p = 0.006] remained an independent risk factor for emergency VAD implantation/death during the HU waiting time.Conclusion: Muscle area of the erector spinae muscle appears to be a potential, easily identifiable risk factor for emergency VAD implantation or death in patients on the HU waiting list for heart transplantation. Identifying patients at risk could help optimize the outcome and the timing of VAD support.
- 18 October 2021
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 8
Open AccessImpact of Muscle Mass as a Prognostic Factor for Failed Waiting Time Prior to Heart Transplantation
Objectives: Clinical deterioration during the waiting time impairs the prognosis of patients listed for heart transplantation. Reduced muscle mass increases the risk for mortality after cardiac surgery, but its impact on resilience against deterioration during the waiting time remains unclear.Methods: We retrospectively analyzed data from 93 patients without a VAD who were listed in Eurotransplant status “high urgent (HU)” for heart transplantation between January 2015 and October 2020. The axial muscle area of the erector spinae muscles at the level of thoracic vertebra 12 indexed to body surface area (TMESA/BSA) measured in the preoperative thoracic computed tomography scan was used to measure muscle mass.Results: Forty patients (43%) underwent emergency VAD implantation during the waiting time and four patients (4%) died during the waiting time. The risk of emergency VAD implantation/death during the waiting time decreased by 10% for every cm2/m2 increase in muscle area [OR 0.901 (95% CI: 0.808–0.996); p = 0.049]. After adjusting for gender [OR 0.318 (95% CI: 0.087–1.073); p = 0.072], mean pulmonary artery pressure [OR 1.061 (95% CI: 0.999–1.131); p = 0.060], C-reactive protein [OR 1.352 (95% CI: 0.986–2.027); p = 0.096], and hemoglobin [OR 0.862 (95% CI: 0.618–1.177); p = 0.360], TMESA/BSA [OR 0.815 (95% CI: 0.698–0.936); p = 0.006] remained an independent risk factor for emergency VAD implantation/death during the HU waiting time.Conclusion: Muscle area of the erector spinae muscle appears to be a potential, easily identifiable risk factor for emergency VAD implantation or death in patients on the HU waiting list for heart transplantation. Identifying patients at risk could help optimize the outcome and the timing of VAD support.
- 3 September 2020
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 31 (4) , 475-482
Prediction of survival of patients in cardiogenic shock treated by surgically implanted Impella 5+ short-term left ventricular assist device
OBJECTIVES: Short-term mechanical circulatory support is a life-saving treatment for acute cardiogenic shock (CS). This multicentre study investigates the preoperative predictors of 30-day mortality in CS patients treated with Impella 5.0 and 5.5 short-term left ventricular assist devices. METHODS: Data of patients in CS (n = 70) treated with the Impella 5 (n = 63) and 5.5 (n = 7) in 2 centres in Berlin between October 2016 and October 2019 were collected retrospectively. RESULTS: CS was caused by acute myocardial infarction (n = 16), decompensated chronic heart failure (n = 41), postcardiotomy syndrome (n = 5) and acute myocarditis (n = 8). Before implantation 12 (17%) patients underwent cardiopulmonary resuscitation and 32 (46%) patients were ventilated. INTERMACS level 1, 2 and 3 was established in 35 (50%), 29 (41%) and 6 (9%) of patients, respectively. The mean preoperative lactate level was 4.05 mmol/l. The median support time was 7 days (IR= 4–15). In 18 cases, the pump was removed for myocardial recovery, in 22 cases, durable left ventricular assist devices were implanted, and 30 patients died on support. The overall 30-day survival was 51%. Statistical analysis showed that an increase in lactate per mmol/l [odds ratio (OR) 1.217; P = 0.015] and cardiopulmonary resuscitation before implantation (OR 16.74; P = 0.009) are predictors of 30-day survival. Based on these data, an algorithm for optimal short-term mechanical circulatory support selection is proposed. CONCLUSIONS: Impella treatment is feasible in severe CS. Severe organ dysfunction, as well as the level and duration of shock predict early mortality. An algorithm based on these parameters may help identify patients who would benefit from Impella 5+ support.
- 3 September 2020
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 31 (4) , 475-482
Prediction of survival of patients in cardiogenic shock treated by surgically implanted Impella 5+ short-term left ventricular assist device
OBJECTIVES: Short-term mechanical circulatory support is a life-saving treatment for acute cardiogenic shock (CS). This multicentre study investigates the preoperative predictors of 30-day mortality in CS patients treated with Impella 5.0 and 5.5 short-term left ventricular assist devices. METHODS: Data of patients in CS (n = 70) treated with the Impella 5 (n = 63) and 5.5 (n = 7) in 2 centres in Berlin between October 2016 and October 2019 were collected retrospectively. RESULTS: CS was caused by acute myocardial infarction (n = 16), decompensated chronic heart failure (n = 41), postcardiotomy syndrome (n = 5) and acute myocarditis (n = 8). Before implantation 12 (17%) patients underwent cardiopulmonary resuscitation and 32 (46%) patients were ventilated. INTERMACS level 1, 2 and 3 was established in 35 (50%), 29 (41%) and 6 (9%) of patients, respectively. The mean preoperative lactate level was 4.05 mmol/l. The median support time was 7 days (IR= 4–15). In 18 cases, the pump was removed for myocardial recovery, in 22 cases, durable left ventricular assist devices were implanted, and 30 patients died on support. The overall 30-day survival was 51%. Statistical analysis showed that an increase in lactate per mmol/l [odds ratio (OR) 1.217; P = 0.015] and cardiopulmonary resuscitation before implantation (OR 16.74; P = 0.009) are predictors of 30-day survival. Based on these data, an algorithm for optimal short-term mechanical circulatory support selection is proposed. CONCLUSIONS: Impella treatment is feasible in severe CS. Severe organ dysfunction, as well as the level and duration of shock predict early mortality. An algorithm based on these parameters may help identify patients who would benefit from Impella 5+ support.
- 21 July 2020
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (10) , 1078-1085
Safety of bioelectrical impedance analysis in advanced heart failure patients
Background: Cardiac cachexia and frailty are major complications of advanced heart failure (AHF). Bioelectrical impedance analysis (BIA) may provide valuable information regarding fluid balance, muscle mass and prognosis. The main concerns regarding the use of BIA in AHF patients remain arrhythmias and electromagnetic interferences with cardiac implantable electronic devices (CIEDs). Reliable data regarding patients on continuous‐flow ventricular assist device (cf‐VAD) remain scarce. The aim of this study is to evaluate the safety of BIA in AHF patients on pro‐arrhythmogenic therapy with an implanted CIED and/or with a cf‐VAD.Methods: We prospectively performed 217 BIA measurements in 143 AHF patients at risk of severe arrhythmias due to inotropic support/a history of ventricular arrhythmias and/or treated with CIED, including 104 patients with an ICD, CRT or pacemaker and 95 patients with a cf‐VAD. All patients were under continuous Electrocardiogram (ECG) monitoring and clinical surveillance for 24 hours.Results: No adverse events were observed during the 217 BIA measurements: No rhythm disturbances were documented in the telemetric monitoring during or within 30 minutes after the measurement. CIEDs showed no malfunction, regardless of the location measured or the device manufacturer. In particular, no inappropriate shocks were observed. No alarms, flow disturbances, or malfunctions of the cf‐VAD occurred during or after the measurements.Conclusion: We consider BIA a safe measurement with major clinical relevance in our cohort of AHF patients, despite an increased arrhythmic potential on inotropic support or the presence of implanted electronic devices (ICD, CRT, pacemaker and cf‐VAD).
- 21 July 2020
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 43 (10) , 1078-1085
Safety of bioelectrical impedance analysis in advanced heart failure patients
Background: Cardiac cachexia and frailty are major complications of advanced heart failure (AHF). Bioelectrical impedance analysis (BIA) may provide valuable information regarding fluid balance, muscle mass and prognosis. The main concerns regarding the use of BIA in AHF patients remain arrhythmias and electromagnetic interferences with cardiac implantable electronic devices (CIEDs). Reliable data regarding patients on continuous‐flow ventricular assist device (cf‐VAD) remain scarce. The aim of this study is to evaluate the safety of BIA in AHF patients on pro‐arrhythmogenic therapy with an implanted CIED and/or with a cf‐VAD.Methods: We prospectively performed 217 BIA measurements in 143 AHF patients at risk of severe arrhythmias due to inotropic support/a history of ventricular arrhythmias and/or treated with CIED, including 104 patients with an ICD, CRT or pacemaker and 95 patients with a cf‐VAD. All patients were under continuous Electrocardiogram (ECG) monitoring and clinical surveillance for 24 hours.Results: No adverse events were observed during the 217 BIA measurements: No rhythm disturbances were documented in the telemetric monitoring during or within 30 minutes after the measurement. CIEDs showed no malfunction, regardless of the location measured or the device manufacturer. In particular, no inappropriate shocks were observed. No alarms, flow disturbances, or malfunctions of the cf‐VAD occurred during or after the measurements.Conclusion: We consider BIA a safe measurement with major clinical relevance in our cohort of AHF patients, despite an increased arrhythmic potential on inotropic support or the presence of implanted electronic devices (ICD, CRT, pacemaker and cf‐VAD).