Interference of cardiovascular implantable electronic devices by static electric and magnetic fields
- 24 March 2021
- journal article
- research article
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 18 (4) , 395-405
Abstract
Introduction: Electromagnetic interference (EMI) of cardiovascular implantable electronic devices (CIED) can lead to malfunctions and pose a danger for implant carriers. The increased use of DC technologies, e.g. in electric mobility, creates more static fields representing an increasing hazard for implant carriers. Areas covered: A combination of approaches was used to determine thresholds for EMI by static fields. A literature search was conducted to identify relevant EMI mechanisms and to extract possible thresholds. The literature search revealed four interference mechanisms caused by static magnetic fields and none for static electric fields. Due to the scarce information on motion-induced EMI, numerical simulations were performed to obtain a threshold. The simulation results were evaluated using medical product standards and benchmark tests on commercially available CIEDs. The results show that motion-induced interference should not occur below the activation of the magnetic safety switch (reed switch or Hall-effect sensor, MSS). Expert opinion: The determined threshold for motion-induced EMI at 24.8 mT shows that the MSS activation is still the most relevant mechanism that can occur at 0.8 mT. Limit values for the general population do not protect implant carriers from EMI.Keywords
Funding Information
- Federal Ministry of Education and Research, Germany (FKZ03SF0495)
This publication has 31 references indexed in Scilit:
- Magnetic Interference of Cardiac Pacemakers from a Surgical Magnetic DrapeAnesthesia & Analgesia, 2013
- Urgent Implantable Cardioverter Defibrillator Deactivation by Unconventional MeansJournal of Pain and Symptom Management, 2011
- Interference of remote magnetic catheter navigation and ablation with implanted devices for pacing and defibrillationEP Europace, 2010
- Leads and longevity: how long will your pacemaker last?EP Europace, 2008
- Cardiac pacemaker: In vitro assessment at 1.5 TAmerican Heart Journal, 2006
- Physical interactions of static magnetic fields with living tissuesProgress in Biophysics and Molecular Biology, 2005
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Return to Arc Welding Following Defibrillator ImplantationPacing and Clinical Electrophysiology, 1993