Kai Jagielski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kai Jagielski has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Dominik Stunder
Research Center for Bioelectromagnetic Interaction - Femu, Institute for Occupational, Social and Environmental Medicine, University Hospital RWTH Aachen, Aachen, Germany
1 shared publication- Dominik Stunder
Research Center for Bioelectromagnetic Interaction (femu) - Institute for Occupational, Social and Environmental Medicine, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074 Aachen, Germany
1 shared publication - Thomas Kraus
Institute of Occupational, Social and Environmental Medicine, Medical Faculty, University Hospital RWTH Aachen, 52074 Aachen, Germany
1 shared publication - Tobias Seckler
The Research Center for Bioelectromagnetic Interaction (FEMU), Institute and Out-patient Clinic of Occupational Medicine, RWTH Aachen University, Pauwelsstr 30, 52074 Aachen, Germany
1 shared publication
Latest Publications
- 24 March 2021
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 18 (4) , 395-405
Interference of cardiovascular implantable electronic devices by static electric and magnetic fields
Introduction: Electromagnetic interference (EMI) of cardiovascular implantable electronic devices (CIED) can lead to malfunctions and pose a danger for implant carriers. The increased use of DC technologies, e.g. in electric mobility, creates more static fields representing an increasing hazard for implant carriers. Areas covered: A combination of approaches was used to determine thresholds for EMI by static fields. A literature search was conducted to identify relevant EMI mechanisms and to extract possible thresholds. The literature search revealed four interference mechanisms caused by static magnetic fields and none for static electric fields. Due to the scarce information on motion-induced EMI, numerical simulations were performed to obtain a threshold. The simulation results were evaluated using medical product standards and benchmark tests on commercially available CIEDs. The results show that motion-induced interference should not occur below the activation of the magnetic safety switch (reed switch or Hall-effect sensor, MSS). Expert opinion: The determined threshold for motion-induced EMI at 24.8 mT shows that the MSS activation is still the most relevant mechanism that can occur at 0.8 mT. Limit values for the general population do not protect implant carriers from EMI.
- 24 March 2021
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 18 (4) , 395-405
Interference of cardiovascular implantable electronic devices by static electric and magnetic fields
Introduction: Electromagnetic interference (EMI) of cardiovascular implantable electronic devices (CIED) can lead to malfunctions and pose a danger for implant carriers. The increased use of DC technologies, e.g. in electric mobility, creates more static fields representing an increasing hazard for implant carriers. Areas covered: A combination of approaches was used to determine thresholds for EMI by static fields. A literature search was conducted to identify relevant EMI mechanisms and to extract possible thresholds. The literature search revealed four interference mechanisms caused by static magnetic fields and none for static electric fields. Due to the scarce information on motion-induced EMI, numerical simulations were performed to obtain a threshold. The simulation results were evaluated using medical product standards and benchmark tests on commercially available CIEDs. The results show that motion-induced interference should not occur below the activation of the magnetic safety switch (reed switch or Hall-effect sensor, MSS). Expert opinion: The determined threshold for motion-induced EMI at 24.8 mT shows that the MSS activation is still the most relevant mechanism that can occur at 0.8 mT. Limit values for the general population do not protect implant carriers from EMI.
- Open Access
- 27 May 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (6) , 5886-5904
Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs). The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIEDs by Qi A13 design magnetic fields were measured and compared with the performance limits set by ISO 14117. In order to carry this out a measuring circuit was developed which can be connected with unipolar or bipolar pacemaker leads. The measuring system was positioned at the four most common implantation sites in a torso phantom filled with physiological saline solution. The phantom was exposed by using Helmholtz coils from 5 µT to 27 µT with 111 kHz sine‑bursts or by using a Qi A13 design wireless charging board (Qi‑A13‑Board) in two operating modes “power transfer” and “pinging”. With the Helmholtz coils the lowest magnetic flux density at which the performance limit was exceeded is 11 µT. With the Qi‑A13‑Board in power transfer mode 10.8% and in pinging mode 45.7% (2.2% at 10 cm distance) of the performance limit were reached at maximum. In neither of the scrutinized cases, did the voltage induced by the Qi‑A13‑Board exceed the performance limits.
- 27 May 2015
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 12 (6) , 5886-5904
Open AccessAssessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board
Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs). The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIEDs by Qi A13 design magnetic fields were measured and compared with the performance limits set by ISO 14117. In order to carry this out a measuring circuit was developed which can be connected with unipolar or bipolar pacemaker leads. The measuring system was positioned at the four most common implantation sites in a torso phantom filled with physiological saline solution. The phantom was exposed by using Helmholtz coils from 5 µT to 27 µT with 111 kHz sine‑bursts or by using a Qi A13 design wireless charging board (Qi‑A13‑Board) in two operating modes “power transfer” and “pinging”. With the Helmholtz coils the lowest magnetic flux density at which the performance limit was exceeded is 11 µT. With the Qi‑A13‑Board in power transfer mode 10.8% and in pinging mode 45.7% (2.2% at 10 cm distance) of the performance limit were reached at maximum. In neither of the scrutinized cases, did the voltage induced by the Qi‑A13‑Board exceed the performance limits.