Abstract
In order to enable variable speed operation, in existing fixed speed pumped storage power plant (PSPP), full scale power converter must be employed to drive the synchronous machines. For such design, high capacity power converter is not economical. Furthermore, full-scale power converters lead to increase the complexity of civil construction in case of underground powerhouses. Therefore, doubly-fed induction machine (DFIM) with slip power rated power converter is an acceptable option for the storage dams with wide variation in water head (e.g. Tehri Dam, India). Thermal stress across the power semiconductor devices is major cause for the failure of power converter and hence it affects the continuity of operation. It is reported that 55% of failure in electric drives are due to thermal cycling or temperature-rise in semiconductor devices. In consideration of this issue, this paper analyses active thermal control based reactive power circulation in a 5-channel parallel-connected back-to-back power converters fed 250 MW DFIM system (data collected from 4×250 MW PSPP under construction at Tehri dam, India). The allowable limit of reactive power range is calculated in consideration of operational strategy to be adopted and circulate it among the converters using vector control technique. It is concluded that because of reactive power circulation among parallel-connected converters, temperature fluctuation is effectively stabilized. PLECS Blockset in Matlab/Simulink software is used for this analysis. Experimental validation is carried out through a 2.2 kW scale-down DFIM laboratory prototype.
Funding Information
  • Central Power Research Institute (CPR-1394-WRC)

This publication has 23 references indexed in Scilit: