Raghu Selvaraj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Raghu Selvaraj has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Thanga Raj Chelliah
Department of Water Resource Development and Management and Centre of Sustainable Energy, Indian Institute of Technology Roorkee (IITR), Roorkee, India
15 shared publications - Chokkalingam Bharatiraja
Centre for Electric Mobility, Department of Electrical and Electronics Engineering, SRM Institute of Science and Technology, Kattankulathur, Chengalpattu, India
8 shared publications - Karthik Desingu
Water Resources Development and Management, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand India 247667
8 shared publications Deepak Khare
Hydropower Simulation Laboratory, Indian Institute of Technology Roorkee
4 shared publications- Sanjeevikumar Padmanaban
Department of Electrical Engineering, IT and Cybernetics, University of South-Eastern Norway, Porsgrunn, Norway
4 shared publications Thanga Raj Chelliah
Hydropower Simulation Laboratory, Indian Institute of Technology Roorkee
4 shared publications
Latest Publications
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12  (5) , 5273-5283
Improved Thermal Behavior of Multi-MW Power Converter Fed Pumped Storage Power Plant During Symmetrical Grid Fault
Variable-speed Pumped Storage Power Plants (PSPPs) are gaining renewed interest from policymakers and hydropower developers due to their improved flexibility in managing real and reactive power under varying water head conditions. In these systems, Doubly-Fed Induction Machines (DFIMs) with multi-megawatt power electronic converters on the rotor side are commonly preferred for high power ratings (over 100 MW). During grid faults, the junction temperature on the power semiconductor devices increases rapidly which leads to the failure of multi-megawatt power electronic converter excitation system. This paper investigates thermal stress on the multi-megawatt power electronic converter system during symmetrical faults in variable-speed PSPPs operating in pumping mode. To mitigate this stress, a coordinated DC-link chopper with demagnetizing control for the Rotor-Side Converter (RSC) is proposed. This strategy effectively controls power semiconductor device temperature during grid faults, and it gives superior results compared to the traditional vector control strategy. Thermal study is performed for a 5-channel parallel connected power converter serving to 250 MW DFIM (to be commissioned in Tehri PSPP, India) operating in pumping mode, and the control strategy’s effectiveness is validated through a scaled-down laboratory prototype.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12  (5) , 5273-5283
Improved Thermal Behavior of Multi-MW Power Converter Fed Pumped Storage Power Plant During Symmetrical Grid Fault
Variable-speed Pumped Storage Power Plants (PSPPs) are gaining renewed interest from policymakers and hydropower developers due to their improved flexibility in managing real and reactive power under varying water head conditions. In these systems, Doubly-Fed Induction Machines (DFIMs) with multi-megawatt power electronic converters on the rotor side are commonly preferred for high power ratings (over 100 MW). During grid faults, the junction temperature on the power semiconductor devices increases rapidly which leads to the failure of multi-megawatt power electronic converter excitation system. This paper investigates thermal stress on the multi-megawatt power electronic converter system during symmetrical faults in variable-speed PSPPs operating in pumping mode. To mitigate this stress, a coordinated DC-link chopper with demagnetizing control for the Rotor-Side Converter (RSC) is proposed. This strategy effectively controls power semiconductor device temperature during grid faults, and it gives superior results compared to the traditional vector control strategy. Thermal study is performed for a 5-channel parallel connected power converter serving to 250 MW DFIM (to be commissioned in Tehri PSPP, India) operating in pumping mode, and the control strategy’s effectiveness is validated through a scaled-down laboratory prototype.
- 19 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11  (1) , 393-403
PV Powered Improved Quasi-Z-Source Inverter Fed Five Phase PMSM for Marine Propulsion Systems
Solar-powered marine vessels face a primary challenge in maintaining a consistent and uninterrupted operation of their propulsion motor, regardless of variations in solar irradiance. Typically, these vessels utilize a photovoltaic (PV) array as the primary power source in quasi-Z-source (qZS) network-based inverters, with the battery connected across one of the network’s capacitors to ensure smooth operation during dynamic power demands. However, this article introduces an improved qZS inverter configuration, where the battery is connected to the qZS input, and the PV array is connected to one of the capacitors through a maximum power point tracking (MPPT) controller. The proposed system offers operational advantages in the hydrogeneration mode of marine propulsion, enabling the charging of batteries while the propeller is running passively. Furthermore, to maximize power extraction from the PV arrays, a dedicated MPPT controller and feed-forward compensated field-oriented control are implemented for the five-phase permanent magnet synchronous motor. To validate the functionality of the proposed converter, a 12 kW system is designed and simulated using MATLAB/Simulink. Real-time simulation is conducted on the OPAL-RT OP4200 RCP/HIL system to evaluate the effectiveness of the system.
- 19 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11  (1) , 393-403
PV Powered Improved Quasi-Z-Source Inverter Fed Five Phase PMSM for Marine Propulsion Systems
Solar-powered marine vessels face a primary challenge in maintaining a consistent and uninterrupted operation of their propulsion motor, regardless of variations in solar irradiance. Typically, these vessels utilize a photovoltaic (PV) array as the primary power source in quasi-Z-source (qZS) network-based inverters, with the battery connected across one of the network’s capacitors to ensure smooth operation during dynamic power demands. However, this article introduces an improved qZS inverter configuration, where the battery is connected to the qZS input, and the PV array is connected to one of the capacitors through a maximum power point tracking (MPPT) controller. The proposed system offers operational advantages in the hydrogeneration mode of marine propulsion, enabling the charging of batteries while the propeller is running passively. Furthermore, to maximize power extraction from the PV arrays, a dedicated MPPT controller and feed-forward compensated field-oriented control are implemented for the five-phase permanent magnet synchronous motor. To validate the functionality of the proposed converter, a 12 kW system is designed and simulated using MATLAB/Simulink. Real-time simulation is conducted on the OPAL-RT OP4200 RCP/HIL system to evaluate the effectiveness of the system.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59  (6) , 6780-6791
Voltage Signature Based Open Circuit Switch Fault Diagnosis Strategy for IM Drives With MPC
Diagnostics of defective leg and switch faults in 3-ph voltage source inverter (VSI) powered induction motor drive system is the primary stage to design the fault-tolerant operation. The preponderance of fault detection techniques largely relies on threshold value-tuning for identifying defective switches. And, using the current component as a variable to determine open circuit switch failure. From this perspective, the paper presents an open circuit switch fault diagnosis strategy for 3-ph 2-level VSI. The strategy is based on the estimated phase voltages, which are immune to false alarms caused by transient conditions and parameter fluctuation. An average objective function from the established model predictive current (MPC) control scheme is selected as the fault diagnosis variable to identify the fault in the 3-ph VSI. The polarities of the estimated normalized mean value of inverter voltages are utilized to localize the open circuit switch fault. With the aid of the aforementioned variables, the developed fault diagnosis technique accurately identifies and locates the faulty switches. The voltage signature for the 18 possible combination faults is developed and realized. To assure the reliability of the established fault identification approach, the IM with 2-level VSI is operated with the open fault in different operating conditions in Matlab/Simulink environment and experimentally validated. The hardware experimentation is performed with 2-level VSI and 3.7 kW three-phase IMD.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59  (6) , 6780-6791
Voltage Signature Based Open Circuit Switch Fault Diagnosis Strategy for IM Drives With MPC
Diagnostics of defective leg and switch faults in 3-ph voltage source inverter (VSI) powered induction motor drive system is the primary stage to design the fault-tolerant operation. The preponderance of fault detection techniques largely relies on threshold value-tuning for identifying defective switches. And, using the current component as a variable to determine open circuit switch failure. From this perspective, the paper presents an open circuit switch fault diagnosis strategy for 3-ph 2-level VSI. The strategy is based on the estimated phase voltages, which are immune to false alarms caused by transient conditions and parameter fluctuation. An average objective function from the established model predictive current (MPC) control scheme is selected as the fault diagnosis variable to identify the fault in the 3-ph VSI. The polarities of the estimated normalized mean value of inverter voltages are utilized to localize the open circuit switch fault. With the aid of the aforementioned variables, the developed fault diagnosis technique accurately identifies and locates the faulty switches. The voltage signature for the 18 possible combination faults is developed and realized. To assure the reliability of the established fault identification approach, the IM with 2-level VSI is operated with the open fault in different operating conditions in Matlab/Simulink environment and experimentally validated. The hardware experimentation is performed with 2-level VSI and 3.7 kW three-phase IMD.
- 16 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59  (2) , 1923-1934
Reactive Power Circulation Based Fault Tolerance Schemes for Multi-Megawatt 3L-NPC Paralleled Converters in Variable Speed Hydro Applications
Parallel connected multi-MW three-level neutral point clamped power converters (3L-NPC) are widely preferred in large-rated variable speed pumped storage unit as it improves operating efficiency and reliability. During open circuit fault conditions/gate drive malfunction, the entire unit must be shut down to ensure the safety of other healthier components. This paper proposes reactive power circulation-based fault tolerance control strategies for grid side converter (GSC) during inner and outer switch fault conditions. In case of an open-circuit fault in outer switches, the normal sinusoidal currents are achieved in GSC by circulating reactive power among the healthy to faulty power converters. In case of an open-circuit fault in inner switches, the reactive power is circulated between healthy converters and a doubly fed induction machine (DFIM). In addition, neutral-point (NP) voltage oscillations are suppressed by injecting a zero-sequence signal into the reference voltage. The feasibility study and performance analysis of the proposed fault tolerance control strategies are carried out in the MATLAB/Simulink 2014a environment for the 250 MW DFIM unit. Furthermore, experimental validation is carried out in 3HP DFIM scale-down laboratory prototype with three parallel connected converters.
- 16 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59  (2) , 1923-1934
Reactive Power Circulation Based Fault Tolerance Schemes for Multi-Megawatt 3L-NPC Paralleled Converters in Variable Speed Hydro Applications
Parallel connected multi-MW three-level neutral point clamped power converters (3L-NPC) are widely preferred in large-rated variable speed pumped storage unit as it improves operating efficiency and reliability. During open circuit fault conditions/gate drive malfunction, the entire unit must be shut down to ensure the safety of other healthier components. This paper proposes reactive power circulation-based fault tolerance control strategies for grid side converter (GSC) during inner and outer switch fault conditions. In case of an open-circuit fault in outer switches, the normal sinusoidal currents are achieved in GSC by circulating reactive power among the healthy to faulty power converters. In case of an open-circuit fault in inner switches, the reactive power is circulated between healthy converters and a doubly fed induction machine (DFIM). In addition, neutral-point (NP) voltage oscillations are suppressed by injecting a zero-sequence signal into the reference voltage. The feasibility study and performance analysis of the proposed fault tolerance control strategies are carried out in the MATLAB/Simulink 2014a environment for the 250 MW DFIM unit. Furthermore, experimental validation is carried out in 3HP DFIM scale-down laboratory prototype with three parallel connected converters.
- 28 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10  (6) , 7691-7703
Open Switch Fault Tolerant Control Strategy for Paralleled Three-Level NPC Back-to-Back Power Converters Fed DFIM Unit
In large rated adjustable speed hydro generating unit, design of fault tolerant control operation is a crucial process due to dynamic slip frequency variation and existence of overvoltage across rotor windings during isolation process of the faulty converter. To overcome these practical challenges, a fault tolerant control strategy is designed in this article for a parallel connected 3L-NPC fed 250 MW DFIM unit. The basic idea is to limit reactive power support under fault tolerant operation to enhance rotor active current amplitude(idm). Meanwhile, PWM signal to the faulty converter is disabled and healthy converters are overloaded to 115% for 10-20 seconds. The overloaded operation in machine side converter shall increase thermal stress on power devices. To handle this issue, average switching cycle of power devices is reduced with the help of state machine controller. Once the system is re-configured, reactive power support to grid is provided with the help of line side converter by adjusting reactive control component (iqrefg). The effectiveness of designed coordinated fault tolerant control strategy is investigated in MATLAB/Simulink2014A environment for 250 MW DFIM unit under different case scenarios. Experimental validation is performed with 3-channel 3L-NPC power converter fed 2.2 kW DFIM unit.
- 28 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10  (6) , 7691-7703
Open Switch Fault Tolerant Control Strategy for Paralleled Three-Level NPC Back-to-Back Power Converters Fed DFIM Unit
In large rated adjustable speed hydro generating unit, design of fault tolerant control operation is a crucial process due to dynamic slip frequency variation and existence of overvoltage across rotor windings during isolation process of the faulty converter. To overcome these practical challenges, a fault tolerant control strategy is designed in this article for a parallel connected 3L-NPC fed 250 MW DFIM unit. The basic idea is to limit reactive power support under fault tolerant operation to enhance rotor active current amplitude(idm). Meanwhile, PWM signal to the faulty converter is disabled and healthy converters are overloaded to 115% for 10-20 seconds. The overloaded operation in machine side converter shall increase thermal stress on power devices. To handle this issue, average switching cycle of power devices is reduced with the help of state machine controller. Once the system is re-configured, reactive power support to grid is provided with the help of line side converter by adjusting reactive control component (iqrefg). The effectiveness of designed coordinated fault tolerant control strategy is investigated in MATLAB/Simulink2014A environment for 250 MW DFIM unit under different case scenarios. Experimental validation is performed with 3-channel 3L-NPC power converter fed 2.2 kW DFIM unit.
- 10 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36  (3) , 1818-1830
Thermal Performance Improvement in Multi-Megawatt Power Converters Serving to Asynchronous Hydro Generators Operating Around Synchronous Speed
In multi-MW three-level neutral point clamped back-to-back (3L-NPC) power converters, power semiconductor devices are considered as most vulnerable components due to its thermo-mechanical fatigue stress. Particularly, rotor side converter (RSC) in doubly fed induction machine (DFIM) experiences high thermal stress during its operation around synchronous speed. It degrades the performance of power converter and reduces the lifetime availability of the drive. In practice, stabilization of temperature fluctuation across each power semiconductor device improves the efficiency and reliability of power converter. With respect to this prime aim, this paper proposes a carrier-based active thermal control method to regulate temperature fluctuation across power semiconductor devices in a multi-MW (5 x 5 MW) 3L-NPC power converters serving to a 250 MW asynchronous hydro-generating unit. To test the proposed active thermal control method, different operating conditions of a 250 MW DFIM hydro-generating unit (to be commissioned in Tehri pumped storage plant, India) are examined in MATLAB/PLECS environment. The designed active thermal control method effectively regulates mean junction temperature and temperature fluctuation of power semiconductor devices within a safe operating limit. The practical feasibility and adoptability of proposed active thermal control is examined through a 2.2-kW DFIM laboratory prototype.
- 10 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36  (3) , 1818-1830
Thermal Performance Improvement in Multi-Megawatt Power Converters Serving to Asynchronous Hydro Generators Operating Around Synchronous Speed
In multi-MW three-level neutral point clamped back-to-back (3L-NPC) power converters, power semiconductor devices are considered as most vulnerable components due to its thermo-mechanical fatigue stress. Particularly, rotor side converter (RSC) in doubly fed induction machine (DFIM) experiences high thermal stress during its operation around synchronous speed. It degrades the performance of power converter and reduces the lifetime availability of the drive. In practice, stabilization of temperature fluctuation across each power semiconductor device improves the efficiency and reliability of power converter. With respect to this prime aim, this paper proposes a carrier-based active thermal control method to regulate temperature fluctuation across power semiconductor devices in a multi-MW (5 x 5 MW) 3L-NPC power converters serving to a 250 MW asynchronous hydro-generating unit. To test the proposed active thermal control method, different operating conditions of a 250 MW DFIM hydro-generating unit (to be commissioned in Tehri pumped storage plant, India) are examined in MATLAB/PLECS environment. The designed active thermal control method effectively regulates mean junction temperature and temperature fluctuation of power semiconductor devices within a safe operating limit. The practical feasibility and adoptability of proposed active thermal control is examined through a 2.2-kW DFIM laboratory prototype.
- 21 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56  (5) , 5439-5451
A Coordinated Control Strategy for a Diesel-Electric Tugboat System for Improved Fuel Economy
Recent growth in seaborne trade has increased tugboat operation cycle to maneuver incoming marine vessels at port. To meet the tugboat load demand for maneuvering, multiple power sources are being employed onboard. This necessitates a coordinated control strategy for effective operation of these multiple power sources. To design an effective coordinated control strategy, this paper initially estimates multiple power source capacities (doubly fed induction machine and battery storage system) for a diesel-electric tugboat system based on a real time tugboat operation cycle obtained from Visakhapatnam port, India. With respect to this multiple power sources, a coordinated control strategy for better fuel efficiency is proposed based on a state machine control algorithm. The proposed control strategy operates variable speed diesel-electric generator (diesel engine coupled with doubly fed induction machine) at minimum specific fuel consumption value and battery based on its state of charge. To show the efficacy of proposed variable speed diesel-electric system, fuel consumption is computed, which resulted 26.42% of saving in comparison with a traditionally used diesel-mechanical tugboat. To evaluate the real time system (2 MW DFIM+ 150 kWh) MATLAB/Simulink tool is used and experimental demonstration is performed on a laboratory prototype.
- 21 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56  (5) , 5439-5451
A Coordinated Control Strategy for a Diesel-Electric Tugboat System for Improved Fuel Economy
Recent growth in seaborne trade has increased tugboat operation cycle to maneuver incoming marine vessels at port. To meet the tugboat load demand for maneuvering, multiple power sources are being employed onboard. This necessitates a coordinated control strategy for effective operation of these multiple power sources. To design an effective coordinated control strategy, this paper initially estimates multiple power source capacities (doubly fed induction machine and battery storage system) for a diesel-electric tugboat system based on a real time tugboat operation cycle obtained from Visakhapatnam port, India. With respect to this multiple power sources, a coordinated control strategy for better fuel efficiency is proposed based on a state machine control algorithm. The proposed control strategy operates variable speed diesel-electric generator (diesel engine coupled with doubly fed induction machine) at minimum specific fuel consumption value and battery based on its state of charge. To show the efficacy of proposed variable speed diesel-electric system, fuel consumption is computed, which resulted 26.42% of saving in comparison with a traditionally used diesel-mechanical tugboat. To evaluate the real time system (2 MW DFIM+ 150 kWh) MATLAB/Simulink tool is used and experimental demonstration is performed on a laboratory prototype.
- 20 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55  (6) , 6414-6426
Effective Utilization of Parallel-Connected Megawatt Three-Level Back-to-Back Power Converters in Variable Speed Pumped Storage Units
Power electronic converter plays a significant role in hydropower generating systems of both fixed and variable speed types. These converters are used in the form of simple rectifier for static dc excitation in fixed speed system and in the form of ac excitation (AC-AC or AC-DC-AC) in variable speed system. Parallel connected multiple three-level neutral-point-clamped (3L-NPC) megawatt back-to-back (BTB) converters have been adopted in recently commissioned variable speed pumped storage units (VSPSU). For such configurations, reliability and efficiency are considered to be prominent. This paper proposes a methodology for effective utilization of parallel-connected BTB power converter for VSPSU of large capacity by performing load dependent activation /deactivation of converters. Vector control strategy for active and reactive power deliveries of VSPSU is formulated. This paper also focusses on losses and thermal behavior of converters at different speeds of generator in accordance with water head variations. The proposed control system is designed in such a way to decrease overall losses in power converter system. The effectiveness of proposed method is explained on a real scale of 250 MW doubly fed induction machine (DFIM) with 5x5 MW power converters using MATLAB/PLECS software and experimental validation is performed through a downscaled 2.2 kW laboratory prototype.
- 20 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55  (6) , 6414-6426
Effective Utilization of Parallel-Connected Megawatt Three-Level Back-to-Back Power Converters in Variable Speed Pumped Storage Units
Power electronic converter plays a significant role in hydropower generating systems of both fixed and variable speed types. These converters are used in the form of simple rectifier for static dc excitation in fixed speed system and in the form of ac excitation (AC-AC or AC-DC-AC) in variable speed system. Parallel connected multiple three-level neutral-point-clamped (3L-NPC) megawatt back-to-back (BTB) converters have been adopted in recently commissioned variable speed pumped storage units (VSPSU). For such configurations, reliability and efficiency are considered to be prominent. This paper proposes a methodology for effective utilization of parallel-connected BTB power converter for VSPSU of large capacity by performing load dependent activation /deactivation of converters. Vector control strategy for active and reactive power deliveries of VSPSU is formulated. This paper also focusses on losses and thermal behavior of converters at different speeds of generator in accordance with water head variations. The proposed control system is designed in such a way to decrease overall losses in power converter system. The effectiveness of proposed method is explained on a real scale of 250 MW doubly fed induction machine (DFIM) with 5x5 MW power converters using MATLAB/PLECS software and experimental validation is performed through a downscaled 2.2 kW laboratory prototype.
- 6 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55  (6) , 7854-7867
Control of Reactive Power for Stabilized Junction Temperature in Power Electronic Devices Serving to a 250-MW Asynchronous Hydrogenerating Unit
In order to enable variable speed operation, in existing fixed speed pumped storage power plant (PSPP), full scale power converter must be employed to drive the synchronous machines. For such design, high capacity power converter is not economical. Furthermore, full-scale power converters lead to increase the complexity of civil construction in case of underground powerhouses. Therefore, doubly-fed induction machine (DFIM) with slip power rated power converter is an acceptable option for the storage dams with wide variation in water head (e.g. Tehri Dam, India). Thermal stress across the power semiconductor devices is major cause for the failure of power converter and hence it affects the continuity of operation. It is reported that 55% of failure in electric drives are due to thermal cycling or temperature-rise in semiconductor devices. In consideration of this issue, this paper analyses active thermal control based reactive power circulation in a 5-channel parallel-connected back-to-back power converters fed 250 MW DFIM system (data collected from 4×250 MW PSPP under construction at Tehri dam, India). The allowable limit of reactive power range is calculated in consideration of operational strategy to be adopted and circulate it among the converters using vector control technique. It is concluded that because of reactive power circulation among parallel-connected converters, temperature fluctuation is effectively stabilized. PLECS Blockset in Matlab/Simulink software is used for this analysis. Experimental validation is carried out through a 2.2 kW scale-down DFIM laboratory prototype.
- 6 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55  (6) , 7854-7867
Control of Reactive Power for Stabilized Junction Temperature in Power Electronic Devices Serving to a 250-MW Asynchronous Hydrogenerating Unit
In order to enable variable speed operation, in existing fixed speed pumped storage power plant (PSPP), full scale power converter must be employed to drive the synchronous machines. For such design, high capacity power converter is not economical. Furthermore, full-scale power converters lead to increase the complexity of civil construction in case of underground powerhouses. Therefore, doubly-fed induction machine (DFIM) with slip power rated power converter is an acceptable option for the storage dams with wide variation in water head (e.g. Tehri Dam, India). Thermal stress across the power semiconductor devices is major cause for the failure of power converter and hence it affects the continuity of operation. It is reported that 55% of failure in electric drives are due to thermal cycling or temperature-rise in semiconductor devices. In consideration of this issue, this paper analyses active thermal control based reactive power circulation in a 5-channel parallel-connected back-to-back power converters fed 250 MW DFIM system (data collected from 4×250 MW PSPP under construction at Tehri dam, India). The allowable limit of reactive power range is calculated in consideration of operational strategy to be adopted and circulate it among the converters using vector control technique. It is concluded that because of reactive power circulation among parallel-connected converters, temperature fluctuation is effectively stabilized. PLECS Blockset in Matlab/Simulink software is used for this analysis. Experimental validation is carried out through a 2.2 kW scale-down DFIM laboratory prototype.
- 29 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55  (6) , 5947-5959
Two-Stage Protection Circuit for a Multichanneled Power Electronic Converter Fed Large Asynchronous Hydrogenerating Unit
Reliable operation of multi-channel power electronic converters in large pumped storage plant is a main concern among policy makers and/or hydropower project developers. This paper aims to design a two-stage protection circuit operation strategy for large rated doubly fed induction machine (DFIM) employed for variable speed pumped storage power plants. The paper initially studies the dynamic behavior of DFIM under symmetrical short circuit faults in both 400-kV power system and stator terminal of the generating unit. Based on the fault analysis a two-stage protection circuit (dc-link braking chopper circuit, crowbar protection circuit) operation strategy is designed in consideration of practical limitations. The designed operation strategy ensures the continuous operation of large rated DFIM under marginal grid disturbances. To investigate the effective operation of two-stage protection circuit, a 250 MW DFIM with multi-channel power converters are implemented in MATLAB/Simulink tool. An experimental test is carried in a 2.2 kW DFIM laboratory prototype.
- 29 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55  (6) , 5947-5959
Two-Stage Protection Circuit for a Multichanneled Power Electronic Converter Fed Large Asynchronous Hydrogenerating Unit
Reliable operation of multi-channel power electronic converters in large pumped storage plant is a main concern among policy makers and/or hydropower project developers. This paper aims to design a two-stage protection circuit operation strategy for large rated doubly fed induction machine (DFIM) employed for variable speed pumped storage power plants. The paper initially studies the dynamic behavior of DFIM under symmetrical short circuit faults in both 400-kV power system and stator terminal of the generating unit. Based on the fault analysis a two-stage protection circuit (dc-link braking chopper circuit, crowbar protection circuit) operation strategy is designed in consideration of practical limitations. The designed operation strategy ensures the continuous operation of large rated DFIM under marginal grid disturbances. To investigate the effective operation of two-stage protection circuit, a 250 MW DFIM with multi-channel power converters are implemented in MATLAB/Simulink tool. An experimental test is carried in a 2.2 kW DFIM laboratory prototype.