Coherence Based Sound Speed Aberration Correction — with clinical validation in fetal ultrasound
- 8 May 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. PP (02780062) , 1
Abstract
The purpose of this work is to demonstrate a robust and clinically validated method for correcting sound speed aberrations in medical ultrasound. We propose a correction method that calculates the focus delays directly from the observed two-way distributed average sound speed. The method beamforms multiple coherence images and selects the sound speed that maximizes the coherence for each image pixel. The main contribution of this work is the direct estimation of aberration, without the ill-conditioned inversion of a local sound speed map, and the proposed processing of coherence images, which adapts to in vivo situations where low coherent regions and off-axis scattering represent a challenge. The method is validated in vitro and in silico showing a high correlation with the ground truth speed of sound maps. Further, the method is clinically validated by being applied to channel data recorded from 172 fetal Bmode images, and 12 case examples are presented and discussed in detail. The data is recorded with a GE HealthCare Voluson Expert 22 system with an eM6c matrix array probe. The images are evaluated by three expert clinicians, and the results show that the corrected images are preferred or gave a quality equivalent to that without correction (1540 m/s) for 72.5% of the 172 images. In addition, a sharpness metric from digital photography is used to quantify image quality improvement. The increase in sharpness and the change in average sound speed are shown to be linearly correlated with a Pearson Correlation Coefficient of 0.67.Keywords
All Related Versions
Funding Information
- Norges Forskningsråd (237887)
This publication has 31 references indexed in Scilit:
- A Comparison of Global and Local Sound Speed Estimation for Aberration Correction in Abdominal Models2023
- vbeam: a Fast and Differentiable Beamformer for Optimizing Ultrasound Imaging2023
- Aberration correction in diagnostic ultrasound: A review of the prior field and current directionsZeitschrift für Medizinische Physik, 2023
- Improving image quality of mid‐trimester fetal sonography in obese women: role of ultrasound propagation velocityUltrasound in Obstetrics & Gynecology, 2018
- Appendix A: Typical Acoustic Properties of Tissues2010
- Sound speed correction in ultrasound imagingUltrasonics, 2006
- A comparison of ultrasonic wavefront distortion and compensation in one-dimensional and two-dimensional aperturesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- A comparison of different focus functions for use in autofocus algorithmsCytometry, 1985
- Properties, implementations and applications of rank filtersImage and Vision Computing, 1985
- Weighted kappa: Nominal scale agreement provision for scaled disagreement or partial credit.Psychological Bulletin, 1968