MMMartin P. Mienkina

Martin P. Mienkina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Martin P. Mienkina has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Coherence Based Sound Speed Aberration Correction — with clinical validation in fetal ultrasound

    by Anders Emil Vrålstad, Peter Fosodeder, Karin Ulrike Deibele, Siri Ann Nyrnes, Ole Marius Hoel Rindal, Vibeke Skoura-Torvik, Martin Mienkina, Svein-Erik Måsøy

    The purpose of this work is to demonstrate a robust and clinically validated method for correcting sound speed aberrations in medical ultrasound. We propose a correction method that calculates the focus delays directly from the observed two-way distributed average sound speed. The method beamforms multiple coherence images and selects the sound speed that maximizes the coherence for each image pixel. The main contribution of this work is the direct estimation of aberration, without the ill-conditioned inversion of a local sound speed map, and the proposed processing of coherence images, which adapts to in vivo situations where low coherent regions and off-axis scattering represent a challenge. The method is validated in vitro and in silico showing a high correlation with the ground truth speed of sound maps. Further, the method is clinically validated by being applied to channel data recorded from 172 fetal Bmode images, and 12 case examples are presented and discussed in detail. The data is recorded with a GE HealthCare Voluson Expert 22 system with an eM6c matrix array probe. The images are evaluated by three expert clinicians, and the results show that the corrected images are preferred or gave a quality equivalent to that without correction (1540 m/s) for 72.5% of the 172 images. In addition, a sharpness metric from digital photography is used to quantify image quality improvement. The increase in sharpness and the change in average sound speed are shown to be linearly correlated with a Pearson Correlation Coefficient of 0.67.

  • Phase shift variance imaging - a new technique for destructive microbubble imaging

    by M. Siepmann, S. Fokong, Martin P. Mienkina, Mara Novak, Wiltrud Lederle, Fabian Kiessling, Jessica Gatjens, Georg Schmitz

    The detection of microbubble contrast agents with ultrasound imaging techniques is the subject of ongoing research. Commonly, the nonlinear response of the agent is employed for detection. The performance of these techniques is, however, affected by nonlinear sound propagation. As an alternative, the change in echo response resulting from microbubble destruction can be employed to detect the agent. In this work, we propose a novel criterion for microbubble destruction detection that allows the rejection of tissue at a defined significance level even for highly echogenic structures in the presence of nonlinear propagation. Most clinical systems provide the hardware requirements for acquisitions consisting of multiple pulses transmitted at the same position, as used in Doppler imaging. Therefore, we develop a processing strategy that distinguishes contrast agent from other stationary or moving structures using these sequences. The proposed criterion is based on the variance of the phase shift of consecutive echoes in the sequence, which, in addition to tissue rejection, permits the distinction of motion from agent disruption. Phantom experiments are conducted to show the validity of the criterion and demonstrate the performance of the new method for contrast detection. Each detection series consists of 20 identical pulses at 9.5 MHz (4.7 MPa peak negative pressure) transmitted at a pulse repetition frequency of 5 kHz. The sequence is applied to phantoms under varied motion and flow conditions. As a first step toward molecular imaging, the technique is applied to microbubbles targeted to vascular endothelial growth factor receptor 2 (VEGFR2) in vitro. The results show a uniform rejection of the background signal while maintaining a contrast enhancement by more than 40 dB. The area under the receiver operating characteristics (ROC) curve is used as the performance metric for the separation of contrast agent and tissue signals, and values larger than 97% demonstrate that an excellent separation was achieved.


  • Photoacoustic coded excitation using periodically perfect sequences

    by Martin F. Beckmann, Claus-Stefan Friedrich, Martin P. Mienkina, Nils C. Gerhardt, Martin R. Hofmann, Georg Schmitz

    Photoacoustic imaging is based on the generation of ultrasound using laser irradiation. Nd:YAG laser systems are commonly employed for this purpose, but cheap and handy pulsed laser diodes can be an attractive alternative. They emit significantly lower pulse energies, but fast averaging is feasible due to high repetition rates. Averaging is limited by the time-of-flight of the acoustic signal, but coded excitation can be used to overcome this limit. Here, we examine the performance of difference set based sequences with perfect correlation properties (periodically perfect sequences, PPS). PPS can be used for continuous, artifact free acquisition, the acquisition scheme is simpler than for all previously reported coding strategies. The coding gain reached for periodic imaging is higher than for Golay codes and Legendre sequences.


  • Monospectral photoacoustic imaging using Legendre sequences

    by Martin F. Beckmann, Claus-Stefan Friedrich, Martin P. Mienkina, Nils C. Gerhardt, Martin R. Hofmann, Georg Schmitz

    Photoacoustic (PA) imaging is an imaging modality based on the generation of ultrasound using laser irradiation. Pulsed laser diodes are an attractive alternative to Q-switched Nd:YAG lasers since they are cheaper and handier. As acoustic time-of-flight limits the pulse repetition frequency (PRF) for averaging, photoacoustic coded excitation (PACE) can be used to enhance the diodes' low signal to noise ratio (SNR). Strategies exhibiting range side lobes can yield higher SNR than previously proposed perfect methods while using simpler code sending procedures. Here, we examine the performance of Legendre sequences (LGS) for PACE. The gain in SNR compared to time equivalent averaging (coding gain) is derived as a function of code length and verified experimentally. The main lobe to peak side lobe ratio (MPSR) of the codes' autocorrelation functions is used to quantify the artifacts introduced by the codes' range side lobes. The coding gain is asymptotically equal to that of previously proposed methods, such as Golay codes (GC) or Simplex codes (SC). For finite code sending time, it exceeds the gain of GC and SC. For a PRF of 500 kHz and an imaging depth of 4.5 cm, the coding gain ranges from about 2 dB (11 bit sequence) to about 5.8 dB (547 bit sequence). Range side lobes are introduced but remain invisible for sufficiently large code lengths, which are necessary for practical applications.


  • Phase shift variance imaging for contrast agent detection

    by Monica Siepmann, Martin P. Mienkina, Georg Schmitz, Stanley Fokong, Zhe Liu, Fabian Kiessling, Jessica Gatjens

    A novel ultrasound contrast agent detection method that selectively detects microbubble (MB) destruction is presented. The detection is based on the variance of the phase shift of consecutive echoes. The variance for stationary echoes or motion at constant speed is determined by the noise of the acquisition system and is theoretically predicted. We hypothesize that the phase shift variance of ultrasound echoes increases during MB destruction. It is expected that this PSV is higher than the PSV for stationary echoes or motion thus allowing the detection of the agent. The hypothesis is experimentally verified in a motion phantom. In a second experiment, MB in very low concentrations are imaged to demonstrate the sensitivity of the method. The results show good agreement with theory and exhibit a clear increase in PSV for MB vs. tissue (44.8 dB). Thus, the phase shift variance can be utilized for ultrasound contrast agent detection. Microbubbles in a concentration of 100 bubbles per ml are sufficient to cause detectable signals with a contrast to tissue ratio of up to 34.7 dB. The acquisition is implemented on a free programmable clinical device. No additions or hardware modifications are necessary making the method easily translatable to most clinical systems.


  • Experimental evaluation of photoacoustic coded excitation using unipolar golay codes

    by Martin P. Mienkina, Claus-Stefan Friedrich, Nils C. Gerhardt, Wilko G. Wilkening, Martin R. Hofmann, Georg Schmitz

    Q-switched Nd:YAG lasers are commonly used as light sources for photoacoustic imaging. However, laser diodes are attractive as an alternative to Nd:YAG lasers because they are less expensive and more compact. Although laser diodes deliver about three orders of magnitude less light pulse energy than Nd:YAG lasers (tens of microjoules compared with tens of millijoules), their pulse repetition frequency (PRF) is four to five orders of magnitude higher (up to 1 MHz compared with tens of hertz); this enables the use of averaging to improve SNR without compromising the image acquisition rate. In photoacoustic imaging, the PRF is limited by the maximum acoustic time-of-flight. This limit can be overcome by using coded excitation schemes in which the coding eliminates ambiguities between echoes induced by subsequent pulses. To evaluate the benefits of photoacoustic coded excitation (PACE), the performance of unipolar Golay codes is investigated analytically and validated experimentally. PACE imaging of a copper slab using laser diodes at a PRF of 1 MHz and a modified clinical ultrasound scanner is successfully demonstrated. Considering laser safety regulations and taking into account a comparison between a laser diode system and Nd:YAG systems with respect to SNR, we conclude that PACE is feasible for small animal imaging.


  • Multispectral photoacoustic coded excitation imaging using unipolar orthogonal Golay codes

    by Martin P. Mienkina, Claus-Stefan Friedrich, Nils C. Gerhardt, Martin F. Beckmann, Martin F. Schiffner, Martin R. Hofmann, Georg Schmitz

    We present a method to speed up the acquisition of multispectral photoacoustic data sets by using unipolar orthogonal Golay codes as excitation sequences for the irradiation system. Multispectral photoacoustic coded excitation (MS-PACE) allows acquiring photoacoustic data sets for two irradiation wavelengths simultaneously and separating them afterwards, thus improving the SNR or speeding up the measurement. We derive an analytical estimation of the SNR improvement using MS-PACE compared to time equivalent averaging. We demonstrate the feasibility of the method by successfully imaging a phantom composed of two dyes using unipolar orthogonal Golay codes as excitation sequence for two high power laser diodes operating at two different wavelengths. The experimental results show very good agreement with the theoretical predictions.


  • Effect of bubble interaction on contrast agent destruction behaviour under repeated insonation

    by Monica Siepmann, Martin P. Mienkina, Georg Schmitz

    The controllable destruction of ultrasound contrast agents plays an important role in quantitative molecular imaging, perfusion estimation, and drug delivery applications. In general, repeated insonation is required to destroy all microbubbles (MB) present. It is expected that MB destruction will depend on MB concentration due to MB interaction and varying attenuation. While attenuation is expected to reduce destruction rates for high concentrations, microbubble interaction may lead to the increased destruction of bubbles during a single pulse sequence. Therefore, we investigate the dependency of the rate of destruction events on the concentration of hard shelled MB to analyze the influence of microbubble interaction. To immobilize the MB during the repeated insonation, microbubbles were embedded in gelatine. Destruction events of single, stationary bubbles can be visualized in Doppler images. This allows the quantification of events in a sequence of frames and thus offers a possibility to analyze destruction rates. Four phantoms with concentrations ranging from 6·104 to 1.5·106 MB/ml were imaged with a Vevo770 system and a RMV 707B scanhead (Visualsonics) in Power Doppler mode. From the total number of colored pixels the number of destruction events was calculated. These were then normalized to the total number of events for a frame sequence to allow comparison of the different concentrations. The results show that the relative decrease of destruction events is slower for lower concentrations. Thus, the results indicate that for high concentrations the destruction threshold of MBs is lowered by neighbouring bubbles.

  • Feasibility study of multispectral photoacoustic coded excitation using orthogonal unipolar Golay codes

    by Martin P. Mienkina, Annika Eder, Georg Schmitz, Claus-Stefan Friedrich, Nils C. Gerhardt, Martin R. Hofmann

    Photoacoustic (PA) imaging is a new imaging modality based on the generation of ultrasound in biological tissue by laser irradiation. It would be desirable to use laser diodes as excitation sources for PA since they are less expensive and more compact than commonly used Nd:YAG lasers. Laser diodes exhibit a higher pulse repetition frequency (PRF) and a lower pulse energy compared to Nd:YAG lasers. In order to increase the SNR of PA imaging using laser diodes, we propose multispectral photoacoustic coded excitation (MS-PACE) based on orthogonal unipolar Golay codes (OUGC). This concept allows acquiring photoacoustic data generated by two laser diodes at two different wavelengths simultaneously and separating them afterwards. The SNR gain and coding gain compared to time equivalent averaging is analytically derived. Furthermore, the feasibility of the concept is experimentally verified. Two laser diodes, emitting light at 850 nm and 905 nm, are triggered according the OUGC scheme. They irradiate a metal slab. The resulting PA signals are acquired using a reconfigured clinical ultrasound system with an 128 element linear array. The data are decoded and images are formed using a delay-and-sum algorithm. Using an 8 bit sequence the SNR is increased by 8.68 dB (905 nm) and 8.87 dB (850 nm). These results are in good agreement with the theoretical SNR gain of 9.03 dB. The resulting images allow a clear discrimination of both wavelengths, demonstrating the feasibility of MS-PACE using OUGC.