A comparison of two methods to calculate axial length
Authors:
- 1 March 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 45 (3) , 284-292
Abstract
To compare prediction accuracy with the axial length (AL) calculation method of the Lenstar biometer (traditional AL) and that of the ARGOS biometer (sum-of-segments AL). Private practice clinic. Comparative case series. Mean absolute error (MAE). Predictions were developed for nine formulas, grouping them into those derived with ultrasound (US) (SRK/T, Holladay 1 and 2, Hoffer Q, Haigis) and those derived with optical biometry (Barrett, OKULIX, Olsen from PhacoOptics, and Olsen from Lenstar). Formulas were ranked by MAE using sum-of-segments AL and traditional AL, in short eyes (traditional AL 26.0 mm), and all eyes. The study comprised 1442 eyes (54 short eyes and 67 long eyes) of 1070 patients. The best-ranking formula for long eyes was Haigis using sum-of-segments AL. For short eyes and for all eyes, OKULIX using sum-of-segments AL was best. Using sum-of-segments AL instead of traditional AL, Holladay 2 improved the most; Olsen from PhacoOptics worsened the most. Some biometers used traditional AL, and at least one used sum-of-segments AL. Formula accuracy varied depending on how various commercial biometers internally calculate AL. Using sum-of-segments AL instead of traditional AL improved predictions for formulas designed on US data (SRK/T, Holladay 1, Holladay 2, Hoffer Q, and Haigis), although it worsened the Barrett and Olsen formulas. OKULIX was generally improved with sum-of-segments AL. When ranking by MAE, OKULIX ranked first.Keywords
This publication has 15 references indexed in Scilit:
- Intraocular lens power in myopic eyesJournal of Cataract & Refractive Surgery, 2015
- Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methodsJournal of Cataract & Refractive Surgery, 2015
- C constant: New concept for ray tracing–assisted intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2014
- Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mmJournal of Cataract & Refractive Surgery, 2011
- Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometryJournal of Cataract & Refractive Surgery, 2011
- Improving refractive outcomes at extreme axial lengths with the IOLMaster: the optical axial length and keratometric transformationBritish Journal of Ophthalmology, 2009
- Intraocular lens calculation accuracy limits in normal eyesJournal of Cataract & Refractive Surgery, 2008
- Calculation of intraocular lens power: a reviewActa Ophthalmologica Scandinavica, 2007
- Errors in self-programming the Hoffer Q formulaEye, 2006
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988