Intraocular lens calculation accuracy limits in normal eyes
Authors:
- Paul-Rolf PreußnerPPPaul-Rolf Preußner
- Thomas OlsenTOThomas Olsen
- Peter HoffmannPHPeter Hoffmann
- Oliver FindlOFOliver Findl
- 1 May 2008
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (5) , 802-808
Abstract
To quantify the current accuracy limits, analyze the residual errors, and propose the next steps for prediction accuracy improvements. Eye hospitals in Germany, Denmark, and Austria. Numerical ray tracing using manufacturer's intraocular lens (IOL) data (vertex radii, central thickness, refractive index) was used for all calculations. Postoperative lens position was predicted by a simple scaling model based on measurements in 1 patient collective. The model was compared with 2 other approaches in 2 patient collectives at 2 hospitals (1121 eyes with 13 IOL models; 936 eyes with 2 models). Axial lengths were measured optically (IOLMaster, Zeiss). No parameter adjustments or individualization of IOL types or of surgeons/localizations were done. The prediction errors and measures of systematic bias for short or long eyes were used to quantify the outcome. The mean prediction errors in the 2 collectives were +0.13 diopter (D) and -0.13 D and the mean absolute errors were 0.44 D and 0.50 D without bias for long or short eyes, but depending on the IOL position model approach. The differences in the mean prediction errors for the IOL types were below the allowed manufacturing tolerances and below human recognition thresholds. The need to individualize and fudge parameters decreases with better physical models of the pseudophakic eye. Further improvements are possible by individual topography to extract corneal asphericity and measured pupil size to calculate the best focus, by improved position predictions based on individual measurements of the crystalline lens and by smaller tolerances for IOL manufacturing.Keywords
This publication has 22 references indexed in Scilit:
- Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1997
- Intraocular lens power formula based on vergence calculation and lens designJournal of Cataract & Refractive Surgery, 1997
- An improved universal theoretical formula for intraocular lens power predictionJournal of Cataract & Refractive Surgery, 1993
- Ein neues Programm zur Berechnung von IntraokularlinsenKlinische Monatsblätter für Augenheilkunde, 1992
- Postoperative Biometry and Keratometry after Posterior Chamber Lens ImplantationEuropean journal of Implant and Refractive Surgery, 1990
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988
- Theoretical approach to intraocular lens calculation using Gaussian opticsJournal of Cataract & Refractive Surgery, 1987
- Posterior chamber implant power calculation: regression formulasAmerican Intra-Ocular Implant Society Journal, 1980
- Intraocular Lens Power CalculationInternational Ophthalmology Clinics, 1979
- Calculation of the power of an iris clip lens for distant vision.British Journal of Ophthalmology, 1973