Abstract
No-insulation (NI) winding technique enables current redistribution during transient events such as quench through bypass conduction paths. In this study, the controlled area bypass (CAB) method is presented to control the time constants in high-temperature superconducting (HTS) coils. The CAB method applies a solder shunt on the coil surface by confining the solder area with a G10 mask structure. Two insulated coils (INS) and one NI coil, each with 50 turns, underwent CAB processing and were tested. The applied solder coverage ranged from 12.5% to 100% of the total surface area, which increased time constants from 0.66 s to 55.6 s for the NI-CAB coil and from 3.9 s to 24.0 s for the INS-CAB coils. A linear relationship was found between the solder coverage and the time constants. Microscopic analysis confirmed an average solder shunt height of below 200 µm across all samples, with penetration depths of 500 µm for INS-CAB coils and 3.7 mm for the NI-CAB coil. During 50 thermal cycles, the time constants remained stable with fluctuations of about 10%. An analytical circuit model considering the details of the solder shunt geometry was established. The average deviations between the estimations and measurements of the contact resistance are 22% for INS-CAB and 17% for NI-CAB. This study contributes to the further understanding of HTS coils with solder surface shunts and the control of time constants for future HTS coil designs.
Funding Information
  • National Natural Science Foundation of China (12327901)
  • Fundamental Research Funds for the Central Universities (lzujbky-2024-jdzx02)

This publication has 50 references indexed in Scilit: