Cedric Korte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cedric Korte has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Peng Song
Tsinghua University
6 shared publications - Timing Qu
State Key Laboratory of Clean and Efficient Turbomachinery Power Equipment, Department of Mechanical Engineering, Tsinghua University, Beijing, China
6 shared publications - Yulong Liu
State Key Laboratory of Clean and Efficient Turbomachinery Power Equipment, Department of Mechanical Engineering, Tsinghua University, Beijing, China
6 shared publications - Liangjun Shao
Francis Bitter Magnet Laboratory, Plasma Science and Fusion Center, Massachusetts Institute of Technology
3 shared publications - Mianjun Xiao
State Key Laboratory of Clean and Efficient Turbomachinery Power Equipment, Department of Mechanical Engineering, Tsinghua University, Beijing, China
3 shared publications - Ziyang Xu
State Key Laboratory of Clean and Efficient Turbomachinery Power Equipment, Department of Mechanical Engineering, Tsinghua University, Beijing, China
3 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by Elsevier in Superconductivity
- Vol. 20
A surrogate model for high-temperature superconducting magnets to predict current distribution with neural networks
- 27 October 2026
- Published by Elsevier in Superconductivity
- Vol. 20
Open AccessA surrogate model for high-temperature superconducting magnets to predict current distribution with neural networks
- 4 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Active Shimming Magnet for Dipole Accelerator to Compensate Sextupole Harmonic Field
An active shimming magnet was developed to compensate sextupole error fields in a block-type REBCO dipole magnet. The magnet employs a sextupole configuration with three no-insulation double-pancake coils wound from 2 mm-wide REBCO tapes. Standalone tests at 77 K confirmed intact electromagnetic performance after winding and assembly. Field quality measurements at 4.2 K under dipole fields of 1.0 T and 3.1 T showed a linear decrease of sextupole component $b_{3}$ with increasing shimming current up to 30 A, with consistent compensation ability at both fields. The active shimming magnet caused an increase in $b_{5}$ and a decrease in $b_{7}$, both with magnitudes much smaller than that of $b_{3}$, indicating limited impact on overall field quality. These results demonstrate that the active shimming magnet effectively reduces sextupole field errors to within 1 unit, providing a compensation approach for improving field quality in future HTS accelerator dipole magnets.
- 4 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Active Shimming Magnet for Dipole Accelerator to Compensate Sextupole Harmonic Field
An active shimming magnet was developed to compensate sextupole error fields in a block-type REBCO dipole magnet. The magnet employs a sextupole configuration with three no-insulation double-pancake coils wound from 2 mm-wide REBCO tapes. Standalone tests at 77 K confirmed intact electromagnetic performance after winding and assembly. Field quality measurements at 4.2 K under dipole fields of 1.0 T and 3.1 T showed a linear decrease of sextupole component $b_{3}$ with increasing shimming current up to 30 A, with consistent compensation ability at both fields. The active shimming magnet caused an increase in $b_{5}$ and a decrease in $b_{7}$, both with magnitudes much smaller than that of $b_{3}$, indicating limited impact on overall field quality. These results demonstrate that the active shimming magnet effectively reduces sextupole field errors to within 1 unit, providing a compensation approach for improving field quality in future HTS accelerator dipole magnets.
- 1 December 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (12) , 125005
Experimental and numerical study on current distribution in parallel co-wound no-insulation coils
No-insulation (NI) coils are known for their high thermal stability and self-protection features due to turn-to-turn contacts. Parallel co-winding is a promising method to reduce the charging delay of NI coils while maintaining thermal stability, demonstrating significant potential for applications in fusion and other large-scale or high-field magnets. The non-uniform current distribution among parallel superconducting tapes in parallel co-wound NI coils may lead to thermal and mechanical stability issues. In this work, we conducted current measurement experiments on small parallel co-wound NI rare-earth barium–copper-oxide coils to investigate the non-uniform current distribution and its influencing factors. The parallel tapes in the input and output sections of the test coils were separated and a series of Rogowski coils was used to measure the current in each tape during ramping charging process. We employed a field-circuit coupled model based on the T–A formulation to calculate the current distribution in co-wound coils. Both the measured and calculated results indicated that the current distribution during ramping was highly non-uniform, with some tapes carrying reverse currents. We calculated the current distribution in co-wound coils with different insulation methods and analyzed the influencing factors of the reverse current. The effects of terminal resistance on current distribution were investigated, and the magnetization and coupling losses during ramping were analyzed. This work could contribute to a deeper understanding of current distribution behavior in co-wound NI coils and provide insights for their application in large-scale or high-field magnets.
- 1 December 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (12) , 125005
Experimental and numerical study on current distribution in parallel co-wound no-insulation coils
No-insulation (NI) coils are known for their high thermal stability and self-protection features due to turn-to-turn contacts. Parallel co-winding is a promising method to reduce the charging delay of NI coils while maintaining thermal stability, demonstrating significant potential for applications in fusion and other large-scale or high-field magnets. The non-uniform current distribution among parallel superconducting tapes in parallel co-wound NI coils may lead to thermal and mechanical stability issues. In this work, we conducted current measurement experiments on small parallel co-wound NI rare-earth barium–copper-oxide coils to investigate the non-uniform current distribution and its influencing factors. The parallel tapes in the input and output sections of the test coils were separated and a series of Rogowski coils was used to measure the current in each tape during ramping charging process. We employed a field-circuit coupled model based on the T–A formulation to calculate the current distribution in co-wound coils. Both the measured and calculated results indicated that the current distribution during ramping was highly non-uniform, with some tapes carrying reverse currents. We calculated the current distribution in co-wound coils with different insulation methods and analyzed the influencing factors of the reverse current. The effects of terminal resistance on current distribution were investigated, and the magnetization and coupling losses during ramping were analyzed. This work could contribute to a deeper understanding of current distribution behavior in co-wound NI coils and provide insights for their application in large-scale or high-field magnets.
- 22 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Test Results and Analysis of a 5 T/34 mm REBCO Dipole Magnet Insert at 4.2 K
High-temperature superconducting (HTS) dipole magnet inserts with higher magnetic fields can improve the performance of future dipole magnets. In support of the 15 T Full-Service-Field Testing Facility for characterizing superconducting materials under extreme transverse fields, we developed a compact HTS insert to generate a 2.5 T field in a 12.5 T LTS background magnet. The magnet comprises six block-type no-insulation double pancakes (DP) wound with REBCO tapes, featuring a 34 mm user bore. Each DP coil includes hard bending at both ends with a bending radius of 1 m. The strong forces induced by high field significantly affect the structural stability of the magnets, presenting a key technical challenge for HTS inserts. To suppress the electromagnetic stress, edge-pressing structures were installed on both sides of the coils, while magnet shells and reinforcement rings were mounted on the outer side. During the self-field test at 4.2 K, the magnet was charged to 301 A, achieving a central field of 5.02 T with measured structural strain below 0.13% . Over three charging cycles, small voltage spikes were observed during current ramping, most of which disappeared in subsequent cycles. No damage was observed afterward. This work provides valuable validation of the design methodology and fabrication techniques for block-type HTS dipole magnets with hard bending.
- 22 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Test Results and Analysis of a 5 T/34 mm REBCO Dipole Magnet Insert at 4.2 K
High-temperature superconducting (HTS) dipole magnet inserts with higher magnetic fields can improve the performance of future dipole magnets. In support of the 15 T Full-Service-Field Testing Facility for characterizing superconducting materials under extreme transverse fields, we developed a compact HTS insert to generate a 2.5 T field in a 12.5 T LTS background magnet. The magnet comprises six block-type no-insulation double pancakes (DP) wound with REBCO tapes, featuring a 34 mm user bore. Each DP coil includes hard bending at both ends with a bending radius of 1 m. The strong forces induced by high field significantly affect the structural stability of the magnets, presenting a key technical challenge for HTS inserts. To suppress the electromagnetic stress, edge-pressing structures were installed on both sides of the coils, while magnet shells and reinforcement rings were mounted on the outer side. During the self-field test at 4.2 K, the magnet was charged to 301 A, achieving a central field of 5.02 T with measured structural strain below 0.13% . Over three charging cycles, small voltage spikes were observed during current ramping, most of which disappeared in subsequent cycles. No damage was observed afterward. This work provides valuable validation of the design methodology and fabrication techniques for block-type HTS dipole magnets with hard bending.
- Open Access
- 19 August 2025
- Published by Elsevier in Superconductivity
- Vol. 15
A low-resistance joint of REBCO stacked cable for large-scale superconducting magnets
- 19 August 2025
- Published by Elsevier in Superconductivity
- Vol. 15
Open AccessA low-resistance joint of REBCO stacked cable for large-scale superconducting magnets
- 1 July 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (7) , 075007
Reliable and predictable time constant tuning in HTS coils using the controlled area bypass method
No-insulation (NI) winding technique enables current redistribution during transient events such as quench through bypass conduction paths. In this study, the controlled area bypass (CAB) method is presented to control the time constants in high-temperature superconducting (HTS) coils. The CAB method applies a solder shunt on the coil surface by confining the solder area with a G10 mask structure. Two insulated coils (INS) and one NI coil, each with 50 turns, underwent CAB processing and were tested. The applied solder coverage ranged from 12.5% to 100% of the total surface area, which increased time constants from 0.66 s to 55.6 s for the NI-CAB coil and from 3.9 s to 24.0 s for the INS-CAB coils. A linear relationship was found between the solder coverage and the time constants. Microscopic analysis confirmed an average solder shunt height of below 200 µm across all samples, with penetration depths of 500 µm for INS-CAB coils and 3.7 mm for the NI-CAB coil. During 50 thermal cycles, the time constants remained stable with fluctuations of about 10%. An analytical circuit model considering the details of the solder shunt geometry was established. The average deviations between the estimations and measurements of the contact resistance are 22% for INS-CAB and 17% for NI-CAB. This study contributes to the further understanding of HTS coils with solder surface shunts and the control of time constants for future HTS coil designs.
- 1 July 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (7) , 075007
Reliable and predictable time constant tuning in HTS coils using the controlled area bypass method
No-insulation (NI) winding technique enables current redistribution during transient events such as quench through bypass conduction paths. In this study, the controlled area bypass (CAB) method is presented to control the time constants in high-temperature superconducting (HTS) coils. The CAB method applies a solder shunt on the coil surface by confining the solder area with a G10 mask structure. Two insulated coils (INS) and one NI coil, each with 50 turns, underwent CAB processing and were tested. The applied solder coverage ranged from 12.5% to 100% of the total surface area, which increased time constants from 0.66 s to 55.6 s for the NI-CAB coil and from 3.9 s to 24.0 s for the INS-CAB coils. A linear relationship was found between the solder coverage and the time constants. Microscopic analysis confirmed an average solder shunt height of below 200 µm across all samples, with penetration depths of 500 µm for INS-CAB coils and 3.7 mm for the NI-CAB coil. During 50 thermal cycles, the time constants remained stable with fluctuations of about 10%. An analytical circuit model considering the details of the solder shunt geometry was established. The average deviations between the estimations and measurements of the contact resistance are 22% for INS-CAB and 17% for NI-CAB. This study contributes to the further understanding of HTS coils with solder surface shunts and the control of time constants for future HTS coil designs.