Probabilities of False Alarm for Vital Sign Detection on the Basis of a Doppler Radar System
Open Access
Abstract
Vital detection on the basis of Doppler radars has drawn a great deal of attention from researchers because of its high potential for applications in biomedicine, surveillance, and finding people alive under debris during natural hazards. In this research, the signal-to-noise ratio (SNR) of the remote vital-sign detection system is investigated. On the basis of different types of noise, such as phase noise, Gaussian noise, leakage noise between the transmitting and receiving antennae, and so on, the SNR of the system has first been examined. Then the research has focused on the investigation of the detection and false alarm probabilities of the system when the transmission link between the human and the radar sensor system took the Nakagami-m channel model. The analytical model for the false alarm and the detection probabilities of the system have been derived. The proposed theoretical models for the SNR and detection probability match with the simulation and measurement results. These theoretical models have the potential to be used as good references for the hardware development of the vital-sign detection radar sensor system.Keywords
Funding Information
- NZ aid program, New Zealand Ministry of Foreign Affairs and Trade
- Faculty for the future program-Schlumberger Foundation
This publication has 18 references indexed in Scilit:
- Improved denoising method for through-wall vital sign detection using UWB impulse radarDigital Signal Processing, 2018
- Integrated Packaging Design of Low-Cost Bondwire Interconnection for 60-GHz CMOS Vital-Signs Radar Sensor Chip With Millimeter-Wave Planar AntennaIEEE Transactions on Components, Packaging and Manufacturing Technology, 2018
- A survey of radar systems for medical applicationsIEEE Aerospace and Electronic Systems Magazine, 2016
- Multi-Human Detection Algorithm Based on an Impulse Radio Ultra-Wideband Radar SystemIEEE Access, 2016
- A Compact Portable Microwave Life-Detection Device for Finding SurvivorsIEEE Embedded Systems Letters, 2015
- SoC CMOS UWB Pulse Radar Sensor for Contactless Respiratory Rate MonitoringIEEE Transactions on Biomedical Circuits and Systems, 2011
- Signal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate MeasurementsIEEE Transactions on Microwave Theory and Techniques, 2009
- FM-UWB for Communications and Radar in Medical ApplicationsWireless Personal Communications, 2009
- Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrierIEEE Transactions on Biomedical Engineering, 2000
- CONTACTLESS APNŒA DETECTOR BASED ON RADARThe Lancet, 1971