Corneal Changes in Progressive Keratoconus After Cross-linking Assessed by Scheimpflug Camera
Authors:
- Kinga KránitzKKKinga Kránitz
- Illés KovácsIKIllés Kovács
- Kata MiháltzKMKata Miháltz
- Gábor László SándorGSGábor László Sándor
- Michael C. KnorzMKMichael C. Knorz
- János NémethJNJános Németh
- Zoltán Zsolt NagyZNZoltán Zsolt Nagy
- 1 September 2012
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 28 (9) , 645-649
Abstract
PURPOSE: To evaluate corneal changes after corneal cross-linking (CXL) in progressive keratoconus with Scheimpflug imaging. METHODS: This prospective analysis included 40 eyes from 22 patients with progressive keratoconus. Corneal CXL was performed in 25 eyes (CXL group) and 15 fellow eyes served as controls (control group). Uncorrected (UDVA) and corrected distance visual acuity (CDVA), thinnest corneal thickness (ThCT), posterior elevation, and Holladay equivalent keratometry values (K1, K2) were determined with Pentacam (Oculus Optikgeräte GmbH) before and 1 year after CXL. Area under the receiver operator characteristic (ROC) curve and multivariable general estimating equation models were used to determine the most sensitive parameters of corneal changes. RESULTS: Manifest sphere (−2.55±3.21 to −1.48±2.39 diopters [D], P =.02), UDVA (0.23±0.25 to 0.31±0.25, P <.001), and CDVA (0.58±0.28 to 0.72±0.19, P =.019) improved significantly in the CXL group. Significant decreases were found in ThCT (472.53±33.18 to 440.53±38.67 μm, P <.001), posterior elevation (68.33±28.69 to 22.67±16.21, P <.001), and keratometry values (K1 [45.06±4.55 to 43.51±4.67 D, P <.001], K2 [48.39±5.41 to 46.71±5.67 D, P <.001]) in the CXL group. These parameters remained stable in controls ( P >.05). According to ROC analysis, posterior elevation change was the most characteristic parameter of corneal change after CXL (area under the curve=0.99). General estimating equation model showed that CXL ( P =.001) and initial ThCT ( P =.007) were significant predictors of decrease in posterior elevation with a significant negative interaction of initial ThCT on CXL effect ( P =.005). CONCLUSIONS: Posterior elevation is a sensitive parameter to monitor corneal remodeling after CXL. Corneal CXL showed augmented effect on corneal protrusion in eyes with thinner corneas.Keywords
This publication has 23 references indexed in Scilit:
- Morphological and functional correlations in riboflavin UV A corneal collagen cross‐linking for keratoconusActa Ophthalmologica, 2012
- Flattening of the cornea after collagen crosslinking for keratoconusJournal of Cataract & Refractive Surgery, 2011
- The role of reference body selection in calculating posterior corneal elevation and prediction of keratoconus using rotating Scheimpflug cameraActa Ophthalmologica, 2010
- Anterior chamber characteristics of keratoconus assessed by rotating Scheimpflug imagingJournal of Cataract & Refractive Surgery, 2010
- Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive SurgeryJournal of Refractive Surgery, 2009
- Complication and failure rates after corneal crosslinkingJournal of Cataract & Refractive Surgery, 2009
- Measuring the cornea: the latest developments in corneal topographyCurrent Opinion in Ophthalmology, 2007
- Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?British Journal of Ophthalmology, 2007
- Crosslinking treatment of progressive keratoconus: new hopeCurrent Opinion in Ophthalmology, 2006
- Biomechanical evidence of the distribution of cross-links in corneastreated with riboflavin and ultraviolet A lightJournal of Cataract & Refractive Surgery, 2006