Escaping ion measurement with high time resolution on CHS

Authors:

Abstract
A scintillator-based lost ion probe can measure the temporal evolution of both the gyroradius and the pitch angle of energetic ions escaping a magnetically confined plasma. For the probe on the Compact Helical System, the time resolution of this detailed two-dimensional measurement is determined by a framing rate of the video camera that records the luminous images produced by the ions striking the scintillator plate. The framing rate of the old camera was 30Hz , thus the time resolution was about 33ms . Our interest is to understand the energetic ion transport in fast events such as a bursting energetic ion driven mode. The typical time scale of these events is less than 1ms , meaning that the old camera was too slow. By replacing it with an image-intensified high-speed video camera system, the temporal resolution was improved from 33to0.07ms . We have successfully installed the fast camera and captured some fast events caused by magnetohydrodynamics, which were unobservable using the original camera.