Compact infrared cryogenic wafer-level camera: design and experimental validation
- 5 March 2012
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (8) , 1049-1060
Abstract
We present a compact infrared cryogenic multichannel camera with a wide field of view equal to 120°. By merging the optics with the detector, the concept is compatible with both cryogenic constraints and wafer-level fabrication. The design strategy of such a camera is described, as well as its fabrication and integration process. Its characterization has been carried out in terms of the modulation transfer function and the noise equivalent temperature difference (NETD). The optical system is limited by the diffraction. By cooling the optics, we achieve a very low NETD equal to 15 mK compared with traditional infrared cameras. A postprocessing algorithm that aims at reconstructing a well-sampled image from the set of undersampled raw subimages produced by the camera is proposed and validated on experimental images.Keywords
Funding Information
- DGA
This publication has 26 references indexed in Scilit:
- Thin wafer-level camera lenses inspired by insect compound eyesOptics Express, 2010
- Ultra-compact close-up microoptical imaging system2010
- The Gabor superlens as an alternative wafer-level camera approach inspired by superposition compound eyes of nocturnal insectsOptics Express, 2009
- Demonstration of an infrared microcamera inspired by Xenos peckii visionApplied Optics, 2009
- Thin compound-eye cameraApplied Optics, 2005
- Microoptical telescope compound eyeOptics Express, 2005
- Artificial apposition compound eye fabricated by micro-optics technologyApplied Optics, 2004
- Miniaturized imaging systemsMicroelectronic Engineering, 2003
- Thin observation module by bound optics (TOMBO): concept and experimental verificationApplied Optics, 2001