Florence de la Barrière
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Florence de la Barrière has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Nicolas Guérineau
ONERA (France)
9 shared publications Guillaume Druart
DOTA, ONERA, Université Paris-Saclay, F-91123 Palaiseau, France
7 shared publicationsJean Taboury
Laboratoire Charles Fabry, Institut d’Optique, CNRS, Université Paris-Sud, 2 avenue Augustin Fresnel, 91127 Palaiseau cedex, France
7 shared publications- Guillaume Druart
DOTA, ONERA, Université Paris-Saclay, 91120 Palaiseau, France
5 shared publications Gilles Lasfargues
CEA LETI MINATEC, 17 rue des Martyrs, F-38054 Grenoble, France
3 shared publicationsNicolas Lhermet
CEA-LETI, Minatec (France)
3 shared publications
Latest Publications
- Open Access
Processing Maps and Nano-IR Diagnostics of Type I Modifications in Mid-IR Germanate-Based Optical Glass
Mid-IR flat/integrated optics require low-loss, programmable phase control. We investigate femtosecond laser direct writing (FLDW) in aluminogermanate glass (Corning 9754), first mapping the processing landscape to delineate no modification, Type I index increase, and spatial broadening regimes. We then operate in a non-accumulating regime that provides a broad, stable writing window. Quantitative-phase microscopy yields Δφ and a monotonic Δn with optically limited cross-sections compatible with low loss. Transmission spectroscopy shows high values (about 90% up to 4 µm) and no additional absorptions across the near-IR and mid-IR range. FTIR reveals a redshift of the Ge–O–(Ge/Al) stretching envelope from ≈1 µJ, correlating with the high Δn onset. s-SNOM at 925 cm−1 resolves the written line as reduced near-field amplitude and decreased phase, confirming a local complex permittivity change consistent with densification-driven Type I tracks. Together, these results define practical conditions for on-demand mid-IR flat/GRIN/Fresnel optics by FLDW in this commercial mid-IR transparent glass.
Open AccessProcessing Maps and Nano-IR Diagnostics of Type I Modifications in Mid-IR Germanate-Based Optical Glass
Mid-IR flat/integrated optics require low-loss, programmable phase control. We investigate femtosecond laser direct writing (FLDW) in aluminogermanate glass (Corning 9754), first mapping the processing landscape to delineate no modification, Type I index increase, and spatial broadening regimes. We then operate in a non-accumulating regime that provides a broad, stable writing window. Quantitative-phase microscopy yields Δφ and a monotonic Δn with optically limited cross-sections compatible with low loss. Transmission spectroscopy shows high values (about 90% up to 4 µm) and no additional absorptions across the near-IR and mid-IR range. FTIR reveals a redshift of the Ge–O–(Ge/Al) stretching envelope from ≈1 µJ, correlating with the high Δn onset. s-SNOM at 925 cm−1 resolves the written line as reduced near-field amplitude and decreased phase, confirming a local complex permittivity change consistent with densification-driven Type I tracks. Together, these results define practical conditions for on-demand mid-IR flat/GRIN/Fresnel optics by FLDW in this commercial mid-IR transparent glass.
- Open Access
- 1 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8813
Photosensitivity of Infrared Glasses under Femtosecond Laser Direct Writing for mid-IR Applications
Chalcogenide glasses are increasingly being developed for photonic applications, particularly in the field of mid-infrared optical imaging. In this paper, we study the photosensitivity of one chalcogenide to direct femtosecond laser writing and its possible applications to micro-optics. Particular attention has been paid to the creation of phase changes and related refractive index variations. This chalcogenide glass was compared with two commercial heavy oxide glasses: Schott SF10 and Corning 9754. We observed different types of permanent modifications depending on the writing speed and the laser pulse energy. Index variations were measured at in the chalcogenide glass while maintaining spectral transmission similar to the pristine materials before irradiation. This provides a good candidate to design optical components for infrared application and helps to unlock the potential of the femtosecond laser direct writing technique to implement at high writing speed and high index changes with low optical losses.- 1 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8813
Open AccessPhotosensitivity of Infrared Glasses under Femtosecond Laser Direct Writing for mid-IR Applications
Chalcogenide glasses are increasingly being developed for photonic applications, particularly in the field of mid-infrared optical imaging. In this paper, we study the photosensitivity of one chalcogenide to direct femtosecond laser writing and its possible applications to micro-optics. Particular attention has been paid to the creation of phase changes and related refractive index variations. This chalcogenide glass was compared with two commercial heavy oxide glasses: Schott SF10 and Corning 9754. We observed different types of permanent modifications depending on the writing speed and the laser pulse energy. Index variations were measured at in the chalcogenide glass while maintaining spectral transmission similar to the pristine materials before irradiation. This provides a good candidate to design optical components for infrared application and helps to unlock the potential of the femtosecond laser direct writing technique to implement at high writing speed and high index changes with low optical losses. - Open Access
- 28 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4490
Femtosecond Laser Direct Writing of Gradient Index Fresnel Lens in GeS2-Based Chalcogenide Glass for Imaging Applications
Chalcogenide glasses have attracted growing interest for their potential to meet the demands of photonic applications in the Mid-Wavelength InfraRed (MWIR) and Long-Wavelength InfraRed (LWIR) transmission windows. In this work, we investigated the photosensitivity to femtosecond laser irradiation of a dedicated chalcogenide glass, along with its possible applications in micro-optics. In order to address the SWaP problem (Size, Weight and Power), this work took advantage of recent techniques in femtosecond laser direct writing to imprint flat and integrated optical systems. Here, we wanted to simplify an infrared multispectral imaging system which combines a lens array and a filter array. Each channel has a focal length of 7 mm and an f-number of 4. We show in this paper that the chosen GeS2-based chalcogenide glass is very promising for the fabrication of graded index optics by fs-laser writing, and particularly for the fabrication of Fresnel lenses. We note a very important phase variation capacity in this infrared material corresponding to refractive index variations up to +0.055. A prototype of Fresnel GRIN lens with a refractive index gradient was fabricated and optically characterized in the Vis range.
- 28 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4490
Open AccessFemtosecond Laser Direct Writing of Gradient Index Fresnel Lens in GeS2-Based Chalcogenide Glass for Imaging Applications
Chalcogenide glasses have attracted growing interest for their potential to meet the demands of photonic applications in the Mid-Wavelength InfraRed (MWIR) and Long-Wavelength InfraRed (LWIR) transmission windows. In this work, we investigated the photosensitivity to femtosecond laser irradiation of a dedicated chalcogenide glass, along with its possible applications in micro-optics. In order to address the SWaP problem (Size, Weight and Power), this work took advantage of recent techniques in femtosecond laser direct writing to imprint flat and integrated optical systems. Here, we wanted to simplify an infrared multispectral imaging system which combines a lens array and a filter array. Each channel has a focal length of 7 mm and an f-number of 4. We show in this paper that the chosen GeS2-based chalcogenide glass is very promising for the fabrication of graded index optics by fs-laser writing, and particularly for the fabrication of Fresnel lenses. We note a very important phase variation capacity in this infrared material corresponding to refractive index variations up to +0.055. A prototype of Fresnel GRIN lens with a refractive index gradient was fabricated and optically characterized in the Vis range.
- 6 June 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (17) , 4761-4770
Compact multichannel infrared camera integrated in an operational detector dewar cooler assembly
We present an ultracompact infrared cryogenic camera integrated inside a standard Sofradir’s detector dewar cooler assembly (DDCA) whose field of view is equal to 120°. The multichannel optical architecture produces four nonredundant images on a single SCORPIO detector with a pixel pitch of 15 μm. This ultraminiaturized optical system brings a very low additional optical and mechanical mass to be cooled in the DDCA: the cool-down time is comparable to an equivalent DDCA without an imagery function. Limiting the number of channels is necessary to keep the highest number of resolved points in the final image. However, optical tolerances lead to irregular shifts between the channels. This paper discusses the limits of multichannel architectures. With an image-processing algorithm, the four images produced by the camera are combined to process a single full-resolution image with an equivalent sampling pitch equal to 7.5 μm. Experimental measurements on the modulation transfer function and noise equivalent temperature difference show that this camera achieves good optical performance.
- 6 June 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (17) , 4761-4770
Compact multichannel infrared camera integrated in an operational detector dewar cooler assembly
We present an ultracompact infrared cryogenic camera integrated inside a standard Sofradir’s detector dewar cooler assembly (DDCA) whose field of view is equal to 120°. The multichannel optical architecture produces four nonredundant images on a single SCORPIO detector with a pixel pitch of 15 μm. This ultraminiaturized optical system brings a very low additional optical and mechanical mass to be cooled in the DDCA: the cool-down time is comparable to an equivalent DDCA without an imagery function. Limiting the number of channels is necessary to keep the highest number of resolved points in the final image. However, optical tolerances lead to irregular shifts between the channels. This paper discusses the limits of multichannel architectures. With an image-processing algorithm, the four images produced by the camera are combined to process a single full-resolution image with an equivalent sampling pitch equal to 7.5 μm. Experimental measurements on the modulation transfer function and noise equivalent temperature difference show that this camera achieves good optical performance.
- 11 July 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (21) , 4936-4944
Fabrication of concave and convex potassium bromide lens arrays by compression molding
A new simple and cost-effective method has been developed for the fabrication of both plano-convex and plano-concave lens arrays with potentially important sag heights. The process is based on the use of potassium bromide (KBr) powder. At ambient temperature and under pressure, KBr powder is compressed on a molding die with the desired shape to form a solid lens array. The quality of the lens arrays has been assessed, and we present the first image produced by a converging KBr lens array.
- 11 July 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (21) , 4936-4944
Fabrication of concave and convex potassium bromide lens arrays by compression molding
A new simple and cost-effective method has been developed for the fabrication of both plano-convex and plano-concave lens arrays with potentially important sag heights. The process is based on the use of potassium bromide (KBr) powder. At ambient temperature and under pressure, KBr powder is compressed on a molding die with the desired shape to form a solid lens array. The quality of the lens arrays has been assessed, and we present the first image produced by a converging KBr lens array.
- 1 May 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8353, 835322
Integration of wide field-of-view imagery functions in a detector dewar cooler assembly
Today, both military and civilian applications require miniaturized optical systems in order to give an imagery function to vehicles with small payload capacity. After the development of megapixel focal plane arrays (FPA) with micro-sized pixels, this miniaturization will become feasible with the integration of optical functions in the detector area. In the field of cooled infrared imaging systems, the detector area is the Detector-Dewar-Cooler Assembly (DDCA). A dewar is a sealed environment where the detector is cooled on a cold plate. We show in this paper that wide field of view imagery functions can be simply added to the dewar. We investigate two ways of integration and make two demonstrators. The first one called FISBI consists in replacing the window by a fish-eye lens and in integrating a lens in the cold shield. This optical system has a field of view of 180°. The second one, called IR-Cam-on-Chip, consists in integrating the optics directly on the focal plane array. This optical system has a field of view of 120°. The additional mass of the optics is sufficiently small to be compatible with the cryogenic environment of the DDCA. The performance of these cameras will be discussed and several evolutions of these cameras will be introduced too.
- 1 May 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8353, 835322
Integration of wide field-of-view imagery functions in a detector dewar cooler assembly
Today, both military and civilian applications require miniaturized optical systems in order to give an imagery function to vehicles with small payload capacity. After the development of megapixel focal plane arrays (FPA) with micro-sized pixels, this miniaturization will become feasible with the integration of optical functions in the detector area. In the field of cooled infrared imaging systems, the detector area is the Detector-Dewar-Cooler Assembly (DDCA). A dewar is a sealed environment where the detector is cooled on a cold plate. We show in this paper that wide field of view imagery functions can be simply added to the dewar. We investigate two ways of integration and make two demonstrators. The first one called FISBI consists in replacing the window by a fish-eye lens and in integrating a lens in the cold shield. This optical system has a field of view of 180°. The second one, called IR-Cam-on-Chip, consists in integrating the optics directly on the focal plane array. This optical system has a field of view of 120°. The additional mass of the optics is sufficiently small to be compatible with the cryogenic environment of the DDCA. The performance of these cameras will be discussed and several evolutions of these cameras will be introduced too.
- 5 March 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (8) , 1049-1060
Compact infrared cryogenic wafer-level camera: design and experimental validation
We present a compact infrared cryogenic multichannel camera with a wide field of view equal to 120°. By merging the optics with the detector, the concept is compatible with both cryogenic constraints and wafer-level fabrication. The design strategy of such a camera is described, as well as its fabrication and integration process. Its characterization has been carried out in terms of the modulation transfer function and the noise equivalent temperature difference (NETD). The optical system is limited by the diffraction. By cooling the optics, we achieve a very low NETD equal to 15 mK compared with traditional infrared cameras. A postprocessing algorithm that aims at reconstructing a well-sampled image from the set of undersampled raw subimages produced by the camera is proposed and validated on experimental images.
- 5 March 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (8) , 1049-1060
Compact infrared cryogenic wafer-level camera: design and experimental validation
We present a compact infrared cryogenic multichannel camera with a wide field of view equal to 120°. By merging the optics with the detector, the concept is compatible with both cryogenic constraints and wafer-level fabrication. The design strategy of such a camera is described, as well as its fabrication and integration process. Its characterization has been carried out in terms of the modulation transfer function and the noise equivalent temperature difference (NETD). The optical system is limited by the diffraction. By cooling the optics, we achieve a very low NETD equal to 15 mK compared with traditional infrared cameras. A postprocessing algorithm that aims at reconstructing a well-sampled image from the set of undersampled raw subimages produced by the camera is proposed and validated on experimental images.
- 29 February 2012
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 41 (10) , 2730-2737
Modulation Transfer Function Measurement of Infrared Focal-Plane Arrays with Small Fill Factors
- 29 February 2012
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 41 (10) , 2730-2737
Modulation Transfer Function Measurement of Infrared Focal-Plane Arrays with Small Fill Factors
- 20 September 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8167, 816704
Original design rules for simple imaging systems
Today, both military and civilian applications require miniaturized and cheap optical systems. To reduce their size and their mass, imaging systems have to be as simple as possible, which means that they have to involve a minimal number of optical elements. The simplest system can be defined as a system which is composed of only three elements: a single optical component, an aperture stop and a detector. However, these elements can be complex if needed: for instance, curved detector, optics with aspheric surfaces or diffractive optical elements, microlens array with a complex shape... This paper aims at presenting the range of optical architectures available for a simple system. Thanks to the formalism of third-order Seidel aberrations, several strategies of simplification and miniaturization of optical systems are examined. This approach leads to a classification of existing miniaturized imaging systems which are described in literature (such as multichannel systems). Figures of merit are also introduced to assess the performance capabilities of such systems, showing the necessary trade-off between simplicity, miniaturization, and optical performance.
- 20 September 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8167, 816704
Original design rules for simple imaging systems
Today, both military and civilian applications require miniaturized and cheap optical systems. To reduce their size and their mass, imaging systems have to be as simple as possible, which means that they have to involve a minimal number of optical elements. The simplest system can be defined as a system which is composed of only three elements: a single optical component, an aperture stop and a detector. However, these elements can be complex if needed: for instance, curved detector, optics with aspheric surfaces or diffractive optical elements, microlens array with a complex shape... This paper aims at presenting the range of optical architectures available for a simple system. Thanks to the formalism of third-order Seidel aberrations, several strategies of simplification and miniaturization of optical systems are examined. This approach leads to a classification of existing miniaturized imaging systems which are described in literature (such as multichannel systems). Figures of merit are also introduced to assess the performance capabilities of such systems, showing the necessary trade-off between simplicity, miniaturization, and optical performance.
- 24 February 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (5) , 684-686
Random phase mask in a filamentation regime: application to the localization of point sources
We present a optical system with an extended point-spread function (PSF) for the localization of point sources in the visible and IR spectral ranges with a subpixel precision. This compact system involves a random phase mask (RPM) as its unique component. It exhibits original properties, because this RPM is used in a particular regime, called the “filamentation regime,” before the speckle region. The localization is performed by calculating the phase correlation between the PSF and the image obtained under off-axis illumination. Numerical simulations are presented to assess the basic optical properties of this RPM in the filamentation regime.
- 24 February 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (5) , 684-686
Random phase mask in a filamentation regime: application to the localization of point sources
We present a optical system with an extended point-spread function (PSF) for the localization of point sources in the visible and IR spectral ranges with a subpixel precision. This compact system involves a random phase mask (RPM) as its unique component. It exhibits original properties, because this RPM is used in a particular regime, called the “filamentation regime,” before the speckle region. The localization is performed by calculating the phase correlation between the PSF and the image obtained under off-axis illumination. Numerical simulations are presented to assess the basic optical properties of this RPM in the filamentation regime.