Apertureless near-field microscopy using a knife blade as a scanning probe at millimeter wavelengths
- 1 October 2012
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (7) , 074907
Abstract
We report on the use of a knife blade as a scanning probe for apertureless near-field microscopy at millimeter wavelengths. Since the knife blade probe is a wider version of the metal tip probe commonly used in this technique, and therefore the interaction area between the probe tip and the sample is larger, an improvement in the intensity of the measured near-field signal is expected. The knife blade probe can also work as a part of a resonator in the illumination optics used in this microscopy format to enhance the strength of the near field that interacts with the sample, resulting in a further improvement in the signal intensity. A scanning method and an image reconstruction algorithm based on computerized tomography are adopted to obtain 2-D near-field images. Experiments performed at 60 GHz using a knife blade with a tip radius of 6 μm ( ) show that the signal intensity is enhanced by 20 dB compared with an equivalent metal tip probe, and that an image resolution approaching the tip radius of the knife blade is achieved.
Keywords
This publication has 35 references indexed in Scilit:
- Nanometer-scale material contrast imaging with a near-field microwave microscopeApplied Physics Letters, 2007
- Quadraxial probe for high resolution near-field scanning rf/microwave microscopyApplied Physics Letters, 2006
- Near-field microwave microscopy on nanometer length scalesJournal of Applied Physics, 2005
- Design and Fabrication of Scanning Near-Field Microwave Probes Compatible With Atomic Force Microscopy to Image Embedded NanostructuresIEEE Transactions on Microwave Theory and Techniques, 2004
- Measurement of electric-field intensities using scanning near-field microwave microscopyIEEE Transactions on Microwave Theory and Techniques, 2003
- High-frequency near-field microscopyReview of Scientific Instruments, 2002
- Calibration of electric coaxial near-field probes and applicationsIEEE Transactions on Microwave Theory and Techniques, 1998
- Contrast of microwave near-field microscopyApplied Physics Letters, 1997
- Extreme sub-wavelength resolution with a scanning radio-frequency transmission microscopeOptics Communications, 1996
- Non-destructive characterization of materials by evanescent microwavesMeasurement Science and Technology, 1993