High Incidence of Intracerebral Hemorrhaging Associated with the Application of Low-Intensity Focused Ultrasound Following Acute Cerebrovascular Injury by Intracortical Injection
Open Access
- 6 October 2022
- journal article
- research article
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (10) , 2120
Abstract
Low-intensity transcranial focused ultrasound (FUS) has gained momentum as a non-/minimally-invasive modality that facilitates the delivery of various pharmaceutical agents to the brain. With the additional ability to modulate regional brain tissue excitability, FUS is anticipated to confer potential neurotherapeutic applications whereby a deeper insight of its safety is warranted. We investigated the effects of FUS applied to the rat brain (Sprague-Dawley) shortly after an intracortical injection of fluorescent interstitial solutes, a widely used convection-enhanced delivery technique that directly (i.e., bypassing the blood–brain-barrier (BBB)) introduces drugs or interstitial tracers to the brain parenchyma. Texas Red ovalbumin (OA) and fluorescein isothiocyanate-dextran (FITC-d) were used as the interstitial tracers. Rats that did not receive sonication showed an expected interstitial distribution of OA and FITC-d around the injection site, with a wider volume distribution of OA (21.8 ± 4.0 µL) compared to that of FITC-d (7.8 ± 2.7 µL). Remarkably, nearly half of the rats exposed to the FUS developed intracerebral hemorrhaging (ICH), with a significantly higher volume of bleeding compared to a minor red blood cell extravasation from the animals that were not exposed to sonication. This finding suggests that the local cerebrovascular injury inflicted by the micro-injection was further exacerbated by the application of sonication, particularly during the acute stage of injury. Smaller tracer volume distributions and weaker fluorescent intensities, compared to the unsonicated animals, were observed for the sonicated rats that did not manifest hemorrhaging, which may indicate an enhanced degree of clearance of the injected tracers. Our results call for careful safety precautions when ultrasound sonication is desired among groups under elevated risks associated with a weakened or damaged vascular integrity.Keywords
Funding Information
- Sponsored Research Agreement with Deepson Bio (2019A013168)
This publication has 75 references indexed in Scilit:
- Ultrasound-assisted convection-enhanced delivery to the brain in vivo with a novel transducer cannula assemblyJournal of Neurosurgery, 2012
- Defense at the Border: The Blood–Brain Barrier Versus Bacterial ForeignersFuture Microbiology, 2012
- Focused ultrasound modulates region-specific brain activityNeuroImage, 2011
- Middle Cerebral Artery Occlusion Model in Rodents: Methods and Potential PitfallsBioMed Research International, 2011
- Review: Cerebral microvascular pathology in ageing and neurodegenerationNeuropathology and Applied Neurobiology, 2010
- Ultrasound-Enhanced Drug Transport and Distribution in the BrainAAPS PharmSciTech, 2010
- Convection-enhanced delivery for the treatment of brain tumorsExpert Review of Neurotherapeutics, 2009
- Characteristics of compounds that cross the blood-brain barrierBMC Neurology, 2009
- Intracortical Hemorrhage Injury in RatsStroke, 2000
- Experimental Intracerebral Hemorrhage in RatsStroke, 1996