EKEvgenii Kim

Evgenii Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Evgenii Kim has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Standardizing TMS Intensity Across Different Coils Using Individualized Electric Field Modeling

    by Evgenii Kim, Mohammad Daneshzand, Keren Zhu, Danyal Fareed Bhutto, Teresa Jacobson Kimberley, Dylan Edwards, Netri Pajankar, Parker Kotlarz, Tommi Raij, Sergey N. Makaroff, et al.

    Quantitative measures for Transcranial Magnetic Stimulation (TMS) intensity are needed to ensure safe and consistent application in therapeutic and research settings. However, resting motor thresholds (rMTs), commonly used to determine stimulation intensity, depend on the coil used. Unless motor mapping and treatment coils are identical, re‐thresholding is necessary, increasing patient discomfort and potentially introducing variability across studies. These considerations raise an unresolved fundamental question: does individual rMT reflect a consistent cortical electric field (E‐field) magnitude independent of coil geometry? We tested the hypothesis that rMT corresponds to a coil‐invariant cortical E‐field magnitude and evaluated a computational method for predicting stimulator output across different coils using a reference rMT. Thirteen healthy, right‐handed participants were recruited; ten were included in the primary analysis. Participants underwent TMS with two figure‐of‐eight coils of different sizes. E‐field distributions were simulated using a fast multipole boundary element method, in free space and within personalized MRI‐based head models. rMT prediction accuracy was compared between a detailed five‐layer and a simplified three‐layer head model, and both were evaluated against direct rMT scaling using the reference coil. The personalized E‐field‐based approach significantly improved rMT prediction accuracy over direct scaling ( p < 0.001). The root‐mean‐square error (RMSE) was 1.26% and 1.32% of maximum stimulator output (MSO) for detailed and simplified models, versus 6.1% MSO for direct scaling. Individual rMT corresponds to a constant cortical E‐field magnitude ratio across coil types. E‐field‐based prediction offers a more accurate, coil‐independent method for standardizing TMS intensity, reducing the need for repeated thresholding.


  • Open Access

    Evaluation of advective solute infiltration into porous media by pulsed focused ultrasound-induced acoustic streaming effects

    by Jared Van Reet, Kate Tunnell, Kara Anderson, Hyun-Chul Kim, Evgenii Kim, Kavin Kowsari, Seung-Schik Yoo

    Purpose: Acoustic streaming induced by applying transcranial focused ultrasound (FUS) promotes localized advective solute transport in the brain and has recently garnered research interest for drug delivery and enhancement of brain waste clearance. The acoustic streaming behavior in brain tissue is difficult to model numerically and thus warrants an in vitro examination of the effects of using different sonication parameters, in terms of frequency, intensity, and pulse duration (PD).Methods: Melamine and polyvinyl alcohol (PVA) foams were used to mimic the porous brain tissue, which contains leptomeningeal fenestrations and perivascular space, while agar hydrogel was used to emulate denser neuropil. FUS was delivered to these media, which were immersed in a phosphate-buffered saline containing toluidine blue O dye, across various frequencies (400, 500, and 600 kHz; applicable to transcranial delivery) in a pulsed mode at two different spatialpeak pulse-average intensities (3 and 4 W/cm2).Results: Image analysis showed that the use of 400 kHz yielded the greatest dye infiltration in melamine foam, while sonication had no impact on infiltration in the agar hydrogel due to the dominance of diffusional transport. Using a fixed spatial-peak temporal-average intensity of 0.4 W/cm2 at 400 kHz, a PD of 75 ms resulted in the greatest infiltration depth in both melamine and PVA foams among the tested range (50-150 ms).Conclusion: These findings suggest the existence of a specific frequency and PD that induce greater enhancement of solute/fluid movement, which may contribute to eventual in vivo applications in promoting waste clearance from the brain.


  • Open Access

    High Incidence of Intracerebral Hemorrhaging Associated with the Application of Low-Intensity Focused Ultrasound Following Acute Cerebrovascular Injury by Intracortical Injection

    by Evgenii Kim, Jared Van Reet, Hyun-Chul Kim, Kavin Kowsari, Seung-Schik Yoo

    Low-intensity transcranial focused ultrasound (FUS) has gained momentum as a non-/minimally-invasive modality that facilitates the delivery of various pharmaceutical agents to the brain. With the additional ability to modulate regional brain tissue excitability, FUS is anticipated to confer potential neurotherapeutic applications whereby a deeper insight of its safety is warranted. We investigated the effects of FUS applied to the rat brain (Sprague-Dawley) shortly after an intracortical injection of fluorescent interstitial solutes, a widely used convection-enhanced delivery technique that directly (i.e., bypassing the blood–brain-barrier (BBB)) introduces drugs or interstitial tracers to the brain parenchyma. Texas Red ovalbumin (OA) and fluorescein isothiocyanate-dextran (FITC-d) were used as the interstitial tracers. Rats that did not receive sonication showed an expected interstitial distribution of OA and FITC-d around the injection site, with a wider volume distribution of OA (21.8 ± 4.0 µL) compared to that of FITC-d (7.8 ± 2.7 µL). Remarkably, nearly half of the rats exposed to the FUS developed intracerebral hemorrhaging (ICH), with a significantly higher volume of bleeding compared to a minor red blood cell extravasation from the animals that were not exposed to sonication. This finding suggests that the local cerebrovascular injury inflicted by the micro-injection was further exacerbated by the application of sonication, particularly during the acute stage of injury. Smaller tracer volume distributions and weaker fluorescent intensities, compared to the unsonicated animals, were observed for the sonicated rats that did not manifest hemorrhaging, which may indicate an enhanced degree of clearance of the injected tracers. Our results call for careful safety precautions when ultrasound sonication is desired among groups under elevated risks associated with a weakened or damaged vascular integrity.