The New Mid-Scala Electrode Array
- 1 September 2014
- journal article
- cochlear implants
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 35 (8) , 1415-1420
Abstract
Hypothesis To analyze the quality of insertion of the newly developed midscala (MS) electrode, which targets a midscalar electrode position to reduce the risk of trauma to the lateral wall and the modiolus. Background Modern cochlear implant surgery aims for a safe intracochlear placement of electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) insertion and the use of lateral wall or perimodiolar electrode placement. Intracochlear trauma after insertion of different electrodes depends on insertion mode and electrode design and may result in trauma to the delicate structures of the cochlear. Methods We performed a temporal bone (TB) trial with insertion of the MS electrode in n = 20 TB‘s after a mastoidectomy and posterior tympanotomy. Insertion was performed either via the RW or a cochleostomy. Electrode positioning, length of insertion, and angle of insertion were analyzed with rotational tomography (RT). TBs were histologically analyzed. Results of RT and histology were compared. Results Scala tympani (ST) insertion could be accomplished reliably by both RW and via a cochleostomy approach. In 20 TBs, 1 scala vestibuli insertion, 1 incomplete (ST), and 1 elevation of basilar membrane were depicted. No trauma was found in 94.7% of all ST insertions. RT allowed determination of the intracochlear electrode position, which was specified by histologic sectioning. Conclusion The new MS electrode seems to fulfill reliable atraumatic intracochlear placement via RW and cochleostomy approaches. RT is available for evaluation of intracochlear electrode position, serving as a potential quality control instrument in human implantation.Keywords
This publication has 17 references indexed in Scilit:
- Round Window Versus Cochleostomy Technique in Cochlear ImplantationOtology & Neurotology, 2012
- Analysis of Intracochlear New Bone and Fibrous Tissue Formation in Human Subjects with Cochlear ImplantsAnnals of Otology, Rhinology & Laryngology, 2007
- Impact of electrode insertion depth on intracochlear traumaOtolaryngology–Head and Neck Surgery, 2006
- Multichannel Cochlear Implants: Relation of Histopathology to PerformanceThe Laryngoscope, 2006
- Quality Control after Cochlear Implant Surgery by Means of Rotational TomographyOtology & Neurotology, 2005
- Conservation of low-frequency hearing in cochlear implantationActa Oto-Laryngologica, 2004
- Evaluation of the HiFocus® electrode array with positioner in human temporal bonesThe Journal of Laryngology & Otology, 2003
- Comparative Study of Cochlear Damage With Three Perimodiolar Electrode DesignsThe Laryngoscope, 2003
- Nondestructive Three-dimensional Analysis of Electrode to Modiolus ProximityOtology & Neurotology, 2002
- The Nucleus Contour Electrode Array: A Radiological and Histological StudyThe Laryngoscope, 2001