Frederike Hassepass
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Frederike Hassepass has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Antje Aschendorff
Department of Otorhinolaryngology—Head and Neck Surgery, Medical Centre—University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
9 shared publications- Susan Arndt
Universitätsklinikum Freiburg, Freiburg im Breisgau, Germany
9 shared publications Roland Laszig
Department of Otorhinolaryngology-Head and Neck Surgery, University Medical Center Freiburg, Killianstrasse 5, 79106, Freiburg, Germany
7 shared publicationsWolfgang Maier
Departments of Otorhinolaryngology–Head and Neck Surgery, and †Nuclear Medicine, University Medical Centre Freiburg, Freiburg, Germany
6 shared publicationsRainer Beck
Departments of Otorhinolaryngology–Head and Neck Surgery, and †Nuclear Medicine, University Medical Centre Freiburg, Freiburg, Germany
4 shared publicationsStefan Bulla
Departments of Otorhinolaryngology–Head and Neck Surgery, and †Nuclear Medicine, University Medical Centre Freiburg, Freiburg, Germany
4 shared publications
Latest Publications
- 22 September 2020
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 42 (1) , e22-e32
Comparison of Speech Recognition and Localization Ability in Single-sided Deaf Patients Implanted With Different Cochlear Implant Electrode Array Designs
Objective: Choice of electrode array (EA) design and differences in outcome are major concerns both to patients with single-sided deafness (SSD) and to surgeons before cochlear implant (CI) surgery. The present work investigates the effects of EA design on 1) insertion depths, and 2) audiological outcomes of SSD CI recipients. Study Design: Retrospective study. Setting: Tertiary academic center. Patients: Forty patients with acquired SSD matched according to duration of deafness Main Outcome Measures: Fourteen CI recipients were implanted with a perimodiolar electrode (cochlear perimodiolar [CPM]), 12 with a shorter lateral wall electrode (cochlear lateral wall [CLW]), and 14 with a longer lateral wall electrode array (medEl lateral wall [MLW]). Postoperative rotational tomography was evaluated to determine cochlear size and EA angle of insertion depth (AID). Binaural speech comprehension in noise (in three configuration presentations) and localization ability were assessed 12 months postoperatively with CI. Results: AID was significantly deeper in MLW (mean 527.94 degrees) compared with the CPM (mean 366.35 degrees) and CLW groups (mean 367.01 degrees). No significant difference in AID was seen between the CPM and CLW groups (difference 0.66 degrees). Cochlear sizes revealed no significant differences between any groups. All three groups showed significant improvement in head shadow effect (difference on average CPM: 6.3 dB SPL, CLW 5 dB SPL, and MLW 4.05 dB SPL) and localization ability at 12 months postoperatively (difference on average CPM: 19.72 degrees, CLW: 24 degrees, and MLW: 12.9 degrees). No significant difference in the extent of audiological benefit was observed between any groups. Conclusion: No effect on binaural benefit was apparent from the selection of the three EA designs in SSD CI recipients. Further studies focusing on subjective results, sound quality, and music perception depending on EA design in SSD CI recipients are needed.
- 22 September 2020
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 42 (1) , e22-e32
Comparison of Speech Recognition and Localization Ability in Single-sided Deaf Patients Implanted With Different Cochlear Implant Electrode Array Designs
Objective: Choice of electrode array (EA) design and differences in outcome are major concerns both to patients with single-sided deafness (SSD) and to surgeons before cochlear implant (CI) surgery. The present work investigates the effects of EA design on 1) insertion depths, and 2) audiological outcomes of SSD CI recipients. Study Design: Retrospective study. Setting: Tertiary academic center. Patients: Forty patients with acquired SSD matched according to duration of deafness Main Outcome Measures: Fourteen CI recipients were implanted with a perimodiolar electrode (cochlear perimodiolar [CPM]), 12 with a shorter lateral wall electrode (cochlear lateral wall [CLW]), and 14 with a longer lateral wall electrode array (medEl lateral wall [MLW]). Postoperative rotational tomography was evaluated to determine cochlear size and EA angle of insertion depth (AID). Binaural speech comprehension in noise (in three configuration presentations) and localization ability were assessed 12 months postoperatively with CI. Results: AID was significantly deeper in MLW (mean 527.94 degrees) compared with the CPM (mean 366.35 degrees) and CLW groups (mean 367.01 degrees). No significant difference in AID was seen between the CPM and CLW groups (difference 0.66 degrees). Cochlear sizes revealed no significant differences between any groups. All three groups showed significant improvement in head shadow effect (difference on average CPM: 6.3 dB SPL, CLW 5 dB SPL, and MLW 4.05 dB SPL) and localization ability at 12 months postoperatively (difference on average CPM: 19.72 degrees, CLW: 24 degrees, and MLW: 12.9 degrees). No significant difference in the extent of audiological benefit was observed between any groups. Conclusion: No effect on binaural benefit was apparent from the selection of the three EA designs in SSD CI recipients. Further studies focusing on subjective results, sound quality, and music perception depending on EA design in SSD CI recipients are needed.
- 23 October 2015
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 273 (9) , 2373-2383
Cochlear implantation for hearing rehabilitation in single-sided deafness after translabyrinthine vestibular schwannoma surgery
The aim of the study was to investigate the option of cochlear implantation (CI) in resultant single-sided deafness associated with unilateral translabyrinthine resection of sporadic vestibular schwannoma (VS). This is a retrospective study performed at Tertiary Care Academic Centre. Following extensive counselling regarding the potential for delayed CI, translabyrinthine VS resection was performed and an intracochlear placeholder was inserted to allow later CI in 11 patients who showed intraoperative microscopic confirmation of preserved cochlear nerve anatomy. Follow-up magnetic resonance imaging (MRI) and promontory testing were performed 1 year after surgery to confirm the absence of VS recurrence and viable cochlea. Confirmed CI candidates underwent a second procedure where the placeholder was removed and the CI inserted (4/11). Preimplant unaided and CI-aided evaluations at 12 and 24 months were performed for subjective and objective hearing outcomes. Tinnitus suppression was also measured for implant on and off effects. Available audiological data for three patients demonstrated significant hearing benefits for ‘speech from deaf/implanted side, noise from the normal-hearing side’ in all three patients and localisation ability improved for 2/3 patients. Subjective findings presented similar results. For the two patients with preimplant tinnitus, complete suppression occurred during active CI. CI is beneficial for hearing rehabilitation and tinnitus reduction in SSD patients with remaining viable cochlear nerve after translabyrinthine VS surgery. Counselling on the risks of intracochlear placeholder insertion and the inherent limitations for ongoing MRI investigations of VS recurrence is essential.
- 23 October 2015
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 273 (9) , 2373-2383
Cochlear implantation for hearing rehabilitation in single-sided deafness after translabyrinthine vestibular schwannoma surgery
The aim of the study was to investigate the option of cochlear implantation (CI) in resultant single-sided deafness associated with unilateral translabyrinthine resection of sporadic vestibular schwannoma (VS). This is a retrospective study performed at Tertiary Care Academic Centre. Following extensive counselling regarding the potential for delayed CI, translabyrinthine VS resection was performed and an intracochlear placeholder was inserted to allow later CI in 11 patients who showed intraoperative microscopic confirmation of preserved cochlear nerve anatomy. Follow-up magnetic resonance imaging (MRI) and promontory testing were performed 1 year after surgery to confirm the absence of VS recurrence and viable cochlea. Confirmed CI candidates underwent a second procedure where the placeholder was removed and the CI inserted (4/11). Preimplant unaided and CI-aided evaluations at 12 and 24 months were performed for subjective and objective hearing outcomes. Tinnitus suppression was also measured for implant on and off effects. Available audiological data for three patients demonstrated significant hearing benefits for ‘speech from deaf/implanted side, noise from the normal-hearing side’ in all three patients and localisation ability improved for 2/3 patients. Subjective findings presented similar results. For the two patients with preimplant tinnitus, complete suppression occurred during active CI. CI is beneficial for hearing rehabilitation and tinnitus reduction in SSD patients with remaining viable cochlear nerve after translabyrinthine VS surgery. Counselling on the risks of intracochlear placeholder insertion and the inherent limitations for ongoing MRI investigations of VS recurrence is essential.
- 1 July 2015
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 36 (6) , 993-1000
Radiologic Results and Hearing Preservation With a Straight Narrow Electrode via Round Window Versus Cochleostomy Approach at Initial Activation
Objective To evaluate the potential influence of two different cochlear implant (CI) electrode carrier approaches to the scala tympani in terms of insertion depth and angle as well as hearing preservation. Study Design Retrospective follow-up study. Setting Tertiary care academic center. Patients Forty-one adult subjects underwent cochlear implantation using the Cochlear Nucleus CI 422 slim straight electrode (Cochlear Limited, New South Wales, Australia) with the intent of achieving atraumatic electrode insertion and hearing preservation. Interventions Fourteen subjects were implanted using a cochleostomy approach and 27 via a round window approach. Main Outcome Measures Radiologic assessment of insertion depth and angle was performed on postoperative rotational tomography. Postoperative low-frequency hearing preservation, complete loss of residual low-frequency hearing, and speech perception in quiet measures were obtained in defined intervals for both groups. Results Mean insertion depth reached 21.5 mm (standard deviation, 1.1), whereas mean insertion angle of 388 degrees (standard deviation, 34.7) was revealed for all CI recipients, with no significant difference between the cochleostomy cohort and the round window cohort. The CI-aided speech perception in quiet showed significantly higher scores 3 to 4 months after activation compared with the preoperative speech perception results. The audiologic data demonstrated no statistically significant difference in probability of complete loss of residual low-frequency hearing at initial activation between the cochleostomy group and the round window group. Conclusion The present results suggest that similar insertion depth and angle as well as similar low-frequency hearing preservation can be achieved in cochlear implantation with this straight narrow electrode via either cochleostomy approach or round window approach at least at initial activation. This fact gives the surgeon the opportunity to adapt access to the scala tympani as needed.
- 1 July 2015
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 36 (6) , 993-1000
Radiologic Results and Hearing Preservation With a Straight Narrow Electrode via Round Window Versus Cochleostomy Approach at Initial Activation
Objective To evaluate the potential influence of two different cochlear implant (CI) electrode carrier approaches to the scala tympani in terms of insertion depth and angle as well as hearing preservation. Study Design Retrospective follow-up study. Setting Tertiary care academic center. Patients Forty-one adult subjects underwent cochlear implantation using the Cochlear Nucleus CI 422 slim straight electrode (Cochlear Limited, New South Wales, Australia) with the intent of achieving atraumatic electrode insertion and hearing preservation. Interventions Fourteen subjects were implanted using a cochleostomy approach and 27 via a round window approach. Main Outcome Measures Radiologic assessment of insertion depth and angle was performed on postoperative rotational tomography. Postoperative low-frequency hearing preservation, complete loss of residual low-frequency hearing, and speech perception in quiet measures were obtained in defined intervals for both groups. Results Mean insertion depth reached 21.5 mm (standard deviation, 1.1), whereas mean insertion angle of 388 degrees (standard deviation, 34.7) was revealed for all CI recipients, with no significant difference between the cochleostomy cohort and the round window cohort. The CI-aided speech perception in quiet showed significantly higher scores 3 to 4 months after activation compared with the preoperative speech perception results. The audiologic data demonstrated no statistically significant difference in probability of complete loss of residual low-frequency hearing at initial activation between the cochleostomy group and the round window group. Conclusion The present results suggest that similar insertion depth and angle as well as similar low-frequency hearing preservation can be achieved in cochlear implantation with this straight narrow electrode via either cochleostomy approach or round window approach at least at initial activation. This fact gives the surgeon the opportunity to adapt access to the scala tympani as needed.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (6) , 882-889
A Comparison of Different Methods to Generate Tooth Surface Models Without Applying Ionizing Radiation for Digital 3-Dimensional Image Fusion With Magnetic Resonance Imaging–Based Data of the Head and Neck Region
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (6) , 882-889
A Comparison of Different Methods to Generate Tooth Surface Models Without Applying Ionizing Radiation for Digital 3-Dimensional Image Fusion With Magnetic Resonance Imaging–Based Data of the Head and Neck Region
- 1 September 2014
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 35 (8) , 1415-1420
The New Mid-Scala Electrode Array
Hypothesis To analyze the quality of insertion of the newly developed midscala (MS) electrode, which targets a midscalar electrode position to reduce the risk of trauma to the lateral wall and the modiolus. Background Modern cochlear implant surgery aims for a safe intracochlear placement of electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) insertion and the use of lateral wall or perimodiolar electrode placement. Intracochlear trauma after insertion of different electrodes depends on insertion mode and electrode design and may result in trauma to the delicate structures of the cochlear. Methods We performed a temporal bone (TB) trial with insertion of the MS electrode in n = 20 TB‘s after a mastoidectomy and posterior tympanotomy. Insertion was performed either via the RW or a cochleostomy. Electrode positioning, length of insertion, and angle of insertion were analyzed with rotational tomography (RT). TBs were histologically analyzed. Results of RT and histology were compared. Results Scala tympani (ST) insertion could be accomplished reliably by both RW and via a cochleostomy approach. In 20 TBs, 1 scala vestibuli insertion, 1 incomplete (ST), and 1 elevation of basilar membrane were depicted. No trauma was found in 94.7% of all ST insertions. RT allowed determination of the intracochlear electrode position, which was specified by histologic sectioning. Conclusion The new MS electrode seems to fulfill reliable atraumatic intracochlear placement via RW and cochleostomy approaches. RT is available for evaluation of intracochlear electrode position, serving as a potential quality control instrument in human implantation.
- 1 September 2014
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 35 (8) , 1415-1420
The New Mid-Scala Electrode Array
Hypothesis To analyze the quality of insertion of the newly developed midscala (MS) electrode, which targets a midscalar electrode position to reduce the risk of trauma to the lateral wall and the modiolus. Background Modern cochlear implant surgery aims for a safe intracochlear placement of electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) insertion and the use of lateral wall or perimodiolar electrode placement. Intracochlear trauma after insertion of different electrodes depends on insertion mode and electrode design and may result in trauma to the delicate structures of the cochlear. Methods We performed a temporal bone (TB) trial with insertion of the MS electrode in n = 20 TB‘s after a mastoidectomy and posterior tympanotomy. Insertion was performed either via the RW or a cochleostomy. Electrode positioning, length of insertion, and angle of insertion were analyzed with rotational tomography (RT). TBs were histologically analyzed. Results of RT and histology were compared. Results Scala tympani (ST) insertion could be accomplished reliably by both RW and via a cochleostomy approach. In 20 TBs, 1 scala vestibuli insertion, 1 incomplete (ST), and 1 elevation of basilar membrane were depicted. No trauma was found in 94.7% of all ST insertions. RT allowed determination of the intracochlear electrode position, which was specified by histologic sectioning. Conclusion The new MS electrode seems to fulfill reliable atraumatic intracochlear placement via RW and cochleostomy approaches. RT is available for evaluation of intracochlear electrode position, serving as a potential quality control instrument in human implantation.
- 27 June 2014
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 272 (9) , 2235-2241
The bonebridge as a transcutaneous bone conduction hearing system: preliminary surgical and audiological results in children and adolescents
The Bonebridge ® (BB, Med-El) is a newly designed transcutaneous active bone conductive implant with functional outcome similar to percutaneous bone-anchored hearing systems (BAHS). It is currently approved only for patients ≥18 years. Since the BB allows the skin to remain intact and therefore should be able to overcome some of the issues related to percutaneous BAHS including skin reactions, wound infection and implant extrusion, it would be especially attractive for use in children. We present a preliminary series of the first three cases of BB implantation in children/adolescents (10–16 years). Two subjects were affected by conductive hearing loss (CHL) and one subject by single-sided deafness (SSD). The surgical procedure with transmastoid approach was completed in all cases without complications. Both subjects with CHL showed an increase in speech perception thresholds in quiet from preoperative unaided to 6 months postoperatively with BB of 37 dB, respectively, of 12 dB. The adolescent with SSD attained –3.1 dB unaided vs. –5.6 dB with the BB in the “speech and noise from the front” presentation and +0.5 unaided vs. –5.0 dB with the BB in the “speech from the unilateral deaf side/noise from the normal hearing side” presentation using the adaptive Oldenburg Sentence Test. The results show a straightforward surgical procedure and satisfactory functional gain after BB implantation also in children/adolescents. BB implantation in patients ≤18 years is currently an “off-label use” so that detailed information about alternative treatment options, operation risks and the lack of approval for use in children is essential.
- 27 June 2014
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 272 (9) , 2235-2241
The bonebridge as a transcutaneous bone conduction hearing system: preliminary surgical and audiological results in children and adolescents
The Bonebridge ® (BB, Med-El) is a newly designed transcutaneous active bone conductive implant with functional outcome similar to percutaneous bone-anchored hearing systems (BAHS). It is currently approved only for patients ≥18 years. Since the BB allows the skin to remain intact and therefore should be able to overcome some of the issues related to percutaneous BAHS including skin reactions, wound infection and implant extrusion, it would be especially attractive for use in children. We present a preliminary series of the first three cases of BB implantation in children/adolescents (10–16 years). Two subjects were affected by conductive hearing loss (CHL) and one subject by single-sided deafness (SSD). The surgical procedure with transmastoid approach was completed in all cases without complications. Both subjects with CHL showed an increase in speech perception thresholds in quiet from preoperative unaided to 6 months postoperatively with BB of 37 dB, respectively, of 12 dB. The adolescent with SSD attained –3.1 dB unaided vs. –5.6 dB with the BB in the “speech and noise from the front” presentation and +0.5 unaided vs. –5.0 dB with the BB in the “speech from the unilateral deaf side/noise from the normal hearing side” presentation using the adaptive Oldenburg Sentence Test. The results show a straightforward surgical procedure and satisfactory functional gain after BB implantation also in children/adolescents. BB implantation in patients ≤18 years is currently an “off-label use” so that detailed information about alternative treatment options, operation risks and the lack of approval for use in children is essential.
- 18 March 2014
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 271 (7) , 2079-2082
MRI artefacts after Bonebridge implantation
The new transcutaneous bone conduction implant (BCI) Bonebridge (BB, MED-EL) allows the skin to remain intact and therefore overcomes some issues related to percutaneous systems, such as skin reaction around the external screw and cosmetic complaints. According to manufacturer, BB is MRI conditional up to 1,5 Tesla (T). The artefact of the neurocranium after BB implantation is extensive as shown in the present report. This has to be taken into account when patients suffering conductive, mixed or single-sided hearing loss with candidacy for a BCI are counselled. In patients with comorbid intracranial tumour or other diseases of the brain that require imaging control scans with MRI percutaneous, BCI should be the implant of choice considering the very small artefact of the percutaneous screw in MRI.
- 18 March 2014
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 271 (7) , 2079-2082
MRI artefacts after Bonebridge implantation
The new transcutaneous bone conduction implant (BCI) Bonebridge (BB, MED-EL) allows the skin to remain intact and therefore overcomes some issues related to percutaneous systems, such as skin reaction around the external screw and cosmetic complaints. According to manufacturer, BB is MRI conditional up to 1,5 Tesla (T). The artefact of the neurocranium after BB implantation is extensive as shown in the present report. This has to be taken into account when patients suffering conductive, mixed or single-sided hearing loss with candidacy for a BCI are counselled. In patients with comorbid intracranial tumour or other diseases of the brain that require imaging control scans with MRI percutaneous, BCI should be the implant of choice considering the very small artefact of the percutaneous screw in MRI.
- 4 February 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (07) , 680-685
Magnet Dislocation: An Increasing and Serious Complication Following MRI in Patients with Cochlear Implants
Purpose: Cochlear implantation (CI) represents the gold standard in the treatment of children born deaf and postlingually deafened adults. Initial magnetic resonance imaging (MRI) was contraindicated in CI users. Meanwhile, there are specific recommendations concerning MRI compatibility depending on the type of CI system and the device manufacturer. Some CI systems are even approved for MRI with the internal magnet left in place. The aim of this study was to analyze all magnet revision surgeries in CI patients at one CI center and the relationship to MRI scans over time. Materials and Methods: Between 2000 and 2013, a total of 2027 CIs were implanted. The number of magnet dislocation (MD) surgeries and their causes was assessed retrospectively. Results: In total 12 cases of MD resulting from an MRI scan (0.59 %) were observed, accounting for 52.2 % of all magnetic revision surgeries. As per the labeling, it was considered safe to leave the internal magnet in place during MRI while following specific manufacturer recommendations: MRI intensity of 1.5 Tesla (T) and compression head bandage during examination. Conclusion: A compression head bandage in a 1.5 T MRI unit does not safely prevent MD and the related serious complications in CI recipients. We recommend a Stenvers view radiograph after MRI with the internal magnet in place for early identification of MD, at least in the case of pain during or after MRI examination. MRI in CI patients should be indicated with restraint and patients should be explicitly informed about the possible risks. Recommendations regarding MRI compatibility and the handling of CI patients issued with MRI for the most common CI systems are summarized. Key Points: • MRI in CI patients: manufacturer recommendations must be followed. • Magnet dislocation due to MRI is a serious complication. • In case of suspected magnet dislocation: Use Stenvers view radiograph for diagnosis. • Instant presentation to a CI center is mandatory for proper management of dislocation. • Immediate CI revision surgery must be performed in the case of magnet dislocation. Citation Format: • Hassepass F, Stabenau V, Arndt S et al. Magnet Dislocation: An Increasing and Serious Complication Following MRI in Patients with Cochlear Implants. Fortschr Röntgenstr 2014; 186: 680 – 685 Ziel: Das Cochlea-Implantat (CI) repräsentiert den Goldstandard in der Therapie von gehörlos geborenen Kindern und postlingual ertaubten Erwachsenen. Initial war die Magnetresonanztomografie (MRT) bei CI-Trägern kontraindiziert. Inzwischen gibt es je nach Implantattyp unterschiedliche Richtlinien zur MRT-Tauglichkeit, sodass bei manchen Systemen sogar mit in situ belassenem internen Magneten eine MRT möglich ist. Ziel dieser Arbeit war die Analyse aller Magnetrevisionsoperationen eines CI-Zentrums bei CI-Patienten und deren Zusammenhang zu MRT-Untersuchungen im zeitlichen Verlauf. Material und Methoden: Zwischen 2000 – 2013 wurden insgesamt 2027 CIs implantiert. Die Anzahl Magnetrevisionsoperationen und deren Ursachen besonders im Zusammenhang mit MRTs wurde retrospektiv ausgewertet. Ergebnisse: Insgesamt wurden 12 Fälle einer Magnetdislokation als Folge einer MRT-Untersuchung beobachtet (0,59 %), welche 52,2 % aller Magnetrevisionsoperationen ausmachten. Die Dislokationen nach MRT traten auf, obwohl alle Sicherheitsempfehlungen des Herstellers befolgt wurden: Intensität der MRT bei 1,5-Tesla (T) und Anlage eines Druckverbands im Bereich des CI vor der Untersuchung. Schlussfolgerung: Der teilweise von Herstellern empfohlene Kompressionsverband im 1,5-T-MRT scheint selbst bei MRT-kompatiblen CIs eine Dislokation des internen Magneten und die damit einhergehenden teils schweren Komplikationen nicht vollständig auszuschließen. Wir empfehlen eine Röntgenuntersuchung nach Stenvers nach erfolgter MRT bei MR-kompatiblem CI und in situ belassenem Magneten zur frühzeitigen Identifizierung einer Dislokation – zumindest im Falle von Schmerzen während oder nach der MRT. Die MRT bei CI-Patienten sollte trotz inzwischen MR-kompatibler Systeme zurückhaltend indiziert und der Patient explizit über eventuelle Folgen aufgeklärt werden. Empfehlungen hinsichtlich der MRT-Kompatibilität und dem Umgang im MRT bei den gängigsten CI-Systemen werden zusammengefasst.
- 4 February 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (07) , 680-685
Magnet Dislocation: An Increasing and Serious Complication Following MRI in Patients with Cochlear Implants
Purpose: Cochlear implantation (CI) represents the gold standard in the treatment of children born deaf and postlingually deafened adults. Initial magnetic resonance imaging (MRI) was contraindicated in CI users. Meanwhile, there are specific recommendations concerning MRI compatibility depending on the type of CI system and the device manufacturer. Some CI systems are even approved for MRI with the internal magnet left in place. The aim of this study was to analyze all magnet revision surgeries in CI patients at one CI center and the relationship to MRI scans over time. Materials and Methods: Between 2000 and 2013, a total of 2027 CIs were implanted. The number of magnet dislocation (MD) surgeries and their causes was assessed retrospectively. Results: In total 12 cases of MD resulting from an MRI scan (0.59 %) were observed, accounting for 52.2 % of all magnetic revision surgeries. As per the labeling, it was considered safe to leave the internal magnet in place during MRI while following specific manufacturer recommendations: MRI intensity of 1.5 Tesla (T) and compression head bandage during examination. Conclusion: A compression head bandage in a 1.5 T MRI unit does not safely prevent MD and the related serious complications in CI recipients. We recommend a Stenvers view radiograph after MRI with the internal magnet in place for early identification of MD, at least in the case of pain during or after MRI examination. MRI in CI patients should be indicated with restraint and patients should be explicitly informed about the possible risks. Recommendations regarding MRI compatibility and the handling of CI patients issued with MRI for the most common CI systems are summarized. Key Points: • MRI in CI patients: manufacturer recommendations must be followed. • Magnet dislocation due to MRI is a serious complication. • In case of suspected magnet dislocation: Use Stenvers view radiograph for diagnosis. • Instant presentation to a CI center is mandatory for proper management of dislocation. • Immediate CI revision surgery must be performed in the case of magnet dislocation. Citation Format: • Hassepass F, Stabenau V, Arndt S et al. Magnet Dislocation: An Increasing and Serious Complication Following MRI in Patients with Cochlear Implants. Fortschr Röntgenstr 2014; 186: 680 – 685 Ziel: Das Cochlea-Implantat (CI) repräsentiert den Goldstandard in der Therapie von gehörlos geborenen Kindern und postlingual ertaubten Erwachsenen. Initial war die Magnetresonanztomografie (MRT) bei CI-Trägern kontraindiziert. Inzwischen gibt es je nach Implantattyp unterschiedliche Richtlinien zur MRT-Tauglichkeit, sodass bei manchen Systemen sogar mit in situ belassenem internen Magneten eine MRT möglich ist. Ziel dieser Arbeit war die Analyse aller Magnetrevisionsoperationen eines CI-Zentrums bei CI-Patienten und deren Zusammenhang zu MRT-Untersuchungen im zeitlichen Verlauf. Material und Methoden: Zwischen 2000 – 2013 wurden insgesamt 2027 CIs implantiert. Die Anzahl Magnetrevisionsoperationen und deren Ursachen besonders im Zusammenhang mit MRTs wurde retrospektiv ausgewertet. Ergebnisse: Insgesamt wurden 12 Fälle einer Magnetdislokation als Folge einer MRT-Untersuchung beobachtet (0,59 %), welche 52,2 % aller Magnetrevisionsoperationen ausmachten. Die Dislokationen nach MRT traten auf, obwohl alle Sicherheitsempfehlungen des Herstellers befolgt wurden: Intensität der MRT bei 1,5-Tesla (T) und Anlage eines Druckverbands im Bereich des CI vor der Untersuchung. Schlussfolgerung: Der teilweise von Herstellern empfohlene Kompressionsverband im 1,5-T-MRT scheint selbst bei MRT-kompatiblen CIs eine Dislokation des internen Magneten und die damit einhergehenden teils schweren Komplikationen nicht vollständig auszuschließen. Wir empfehlen eine Röntgenuntersuchung nach Stenvers nach erfolgter MRT bei MR-kompatiblem CI und in situ belassenem Magneten zur frühzeitigen Identifizierung einer Dislokation – zumindest im Falle von Schmerzen während oder nach der MRT. Die MRT bei CI-Patienten sollte trotz inzwischen MR-kompatibler Systeme zurückhaltend indiziert und der Patient explizit über eventuelle Folgen aufgeklärt werden. Empfehlungen hinsichtlich der MRT-Kompatibilität und dem Umgang im MRT bei den gängigsten CI-Systemen werden zusammengefasst.
- 1 January 2014
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 35 (1) , 29-34
Revision Surgery Due to Magnet Dislocation in Cochlear Implant Patients
Objectives To analyze the cause and effect of magnet dislocation in cochlear implant (CI) recipients requiring magnet revision surgery for treatment. Study Design Retrospective study. Setting Tertiary referral center. Interventions Case reports from 1,706 CI recipients consecutively implanted from January 2000 to December 2011 were reviewed. The number of cases requiring magnet revision surgery was assessed. Results Revision surgery involving magnet removal or replacement was indicated in 1.23% (21/1,706), of all CI recipients. Magnet dislocation occurring during magnetic resonance tomography (MRI), at 1.5 Tesla (T), with the magnet in place and with the application of compression bandaging around the head, was the main cause for revision surgery in 47.62% (10/21) of the affected cases. All 10 cases were implanted with Cochlear Nucleus cochlear implants. These events occurred, despite adherence to current recommendations of the manufacturer. Conclusion The present study underlines that MRI examination is the main cause of magnet dislocation. The use of compressive bandaging when using 1.5-T MRI does not eliminate the risk of magnet dislocation. Additional cautionary measures are for required for conditional MRI. We recommend X-ray examination after MRI to determine magnet dislocation and avoid major complications in all cases reporting pain during or after MRI. Additional research regarding silicon magnet pocket design for added retention is needed. Effective communication of guidelines for precautionary measures during MRI examination in CI patients is mandatory for all clinicians involved. MRI in CI recipients should be indicated with caution.
- 1 January 2014
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 35 (1) , 29-34
Revision Surgery Due to Magnet Dislocation in Cochlear Implant Patients
Objectives To analyze the cause and effect of magnet dislocation in cochlear implant (CI) recipients requiring magnet revision surgery for treatment. Study Design Retrospective study. Setting Tertiary referral center. Interventions Case reports from 1,706 CI recipients consecutively implanted from January 2000 to December 2011 were reviewed. The number of cases requiring magnet revision surgery was assessed. Results Revision surgery involving magnet removal or replacement was indicated in 1.23% (21/1,706), of all CI recipients. Magnet dislocation occurring during magnetic resonance tomography (MRI), at 1.5 Tesla (T), with the magnet in place and with the application of compression bandaging around the head, was the main cause for revision surgery in 47.62% (10/21) of the affected cases. All 10 cases were implanted with Cochlear Nucleus cochlear implants. These events occurred, despite adherence to current recommendations of the manufacturer. Conclusion The present study underlines that MRI examination is the main cause of magnet dislocation. The use of compressive bandaging when using 1.5-T MRI does not eliminate the risk of magnet dislocation. Additional cautionary measures are for required for conditional MRI. We recommend X-ray examination after MRI to determine magnet dislocation and avoid major complications in all cases reporting pain during or after MRI. Additional research regarding silicon magnet pocket design for added retention is needed. Effective communication of guidelines for precautionary measures during MRI examination in CI patients is mandatory for all clinicians involved. MRI in CI recipients should be indicated with caution.
- 1 September 2013
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 34 (7) , 1278-1283
Clinical Outcome After Cochlear Implantation in Patients With Unilateral Hearing Loss Due to Labyrinthitis Ossificans
Cochlear implantation (CI) is the treatment of choice in bilateral labyrinthitis ossificans (LO). The aim of this clinical case study was to evaluate audiologic and subjective outcomes after CI treatment for unilateral hearing loss (UHL) because of LO and to identify optimal timing for treatment. Three subjects (age 40, 54, and 68 yr) with UHL because of LO were enrolled. Duration of deafness was 1.5, 12, and 120 months. After extensive consultation, testing with conventional contralateral routing of signal hearing aid and bone-anchored hearing instrument, CI candidacy was confirmed and CI surgery performed. Test of open-set speech recognition in background noise and sound localization were performed preoperatively, in unaided and aided conditions, and in the CI-aided condition, at 6 and 12 months postoperatively. Subjective assessment via the Speech, Spatial and Qualities scale (SSQ) and the Tinnitus Visual Analogue Scale was performed at preimplant and 12 months postimplant. The data show moderate-to-high hearing benefit after CI in 2 cases and no benefit for the third. SSQ and tinnitus scales show benefit from CI use in both cases. CI treatment should be performed as early as possible, ideally before signs of obliteration are evident. Counseling on all rehabilitation options is important.
- 1 September 2013
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 34 (7) , 1278-1283
Clinical Outcome After Cochlear Implantation in Patients With Unilateral Hearing Loss Due to Labyrinthitis Ossificans
Cochlear implantation (CI) is the treatment of choice in bilateral labyrinthitis ossificans (LO). The aim of this clinical case study was to evaluate audiologic and subjective outcomes after CI treatment for unilateral hearing loss (UHL) because of LO and to identify optimal timing for treatment. Three subjects (age 40, 54, and 68 yr) with UHL because of LO were enrolled. Duration of deafness was 1.5, 12, and 120 months. After extensive consultation, testing with conventional contralateral routing of signal hearing aid and bone-anchored hearing instrument, CI candidacy was confirmed and CI surgery performed. Test of open-set speech recognition in background noise and sound localization were performed preoperatively, in unaided and aided conditions, and in the CI-aided condition, at 6 and 12 months postoperatively. Subjective assessment via the Speech, Spatial and Qualities scale (SSQ) and the Tinnitus Visual Analogue Scale was performed at preimplant and 12 months postimplant. The data show moderate-to-high hearing benefit after CI in 2 cases and no benefit for the third. SSQ and tinnitus scales show benefit from CI use in both cases. CI treatment should be performed as early as possible, ideally before signs of obliteration are evident. Counseling on all rehabilitation options is important.