B0 shimming of the human heart at 7T
Authors:
Open Access
- 23 July 2020
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (1) , 182-196
Abstract
Purpose: Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B0‐field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed.Methods: The spatial B0‐field distribution in the heart was analyzed as well as temporal B0‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration‐based B0‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming.Results: The strongest B0‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B0‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents.Conclusion: Challenges in state‐of‐the‐art B0 shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (#01EO1504)
This publication has 41 references indexed in Scilit:
- Cardiovascular magnetic resonance artefactsJournal of Cardiovascular Magnetic Resonance, 2013
- High Spatial Resolution and Temporally Resolved T2* Mapping of Normal Human Myocardium at 7.0 Tesla: An Ultrahigh Field Magnetic Resonance Feasibility StudyPLOS ONE, 2012
- Dynamic multi-coil shimming of the human brain at 7TJournal of Magnetic Resonance, 2011
- 7 Tesla (T) human cardiovascular magnetic resonance imaging using FLASH and SSFP to assess cardiac function: validation against 1.5 T and 3 T.NMR in Biomedicine, 2011
- Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 TeslaJournal of Cardiovascular Magnetic Resonance, 2010
- Dynamic shimming of the human brain at 7 TConcepts in Magnetic Resonance Part B, 2010
- Magnetic field modeling with a set of individual localized coilsJournal of Magnetic Resonance, 2010
- Simultaneous B0‐ and B1+‐Map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 TMagnetic Resonance in Medicine, 2010
- Initial results on in vivo human coronary MR angiography at 7 TMagnetic Resonance in Medicine, 2009
- Initial results of cardiac imaging at 7 teslaMagnetic Resonance in Medicine, 2008