Stefan Herz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stefan Herz has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Patrick Vogel
Department of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany
7 shared publications Thorsten A. Bley
Affiliation Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany
7 shared publications- Volker Christian Behr
University of Würzburg
7 shared publications Martin A. Rückert
Department of Experimental Physics 5 (Biophysics), University of Würzburg, 97074 Würzburg, Germany
4 shared publications- Thomas Kampf
Department of Neuroradiology, University Hospital Würzburg, 97080 Würzburg, Germany
4 shared publications Patrick Vogel
Affiliation Department of Experimental Physics V, University of Würzburg, Würzburg, Germany
3 shared publications
Latest Publications
- Open Access
- 29 June 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (6) , e0270689
Effects of image homogeneity on stenosis visualization at 7 T in a coronary artery phantom study: With and without B1-shimming and parallel transmission
Background: To investigate the effects of B1-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI). Methods: Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field. Results: B1-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B1-shimming showed shading artifacts due to local B1+-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B1-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p1-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study. Conclusions: B1-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.
- 29 June 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (6) , e0270689
Open AccessEffects of image homogeneity on stenosis visualization at 7 T in a coronary artery phantom study: With and without B1-shimming and parallel transmission
Background: To investigate the effects of B1-shimming and radiofrequency (RF) parallel transmission (pTX) on the visualization and quantification of the degree of stenosis in a coronary artery phantom using 7 Tesla (7 T) magnetic resonance imaging (MRI). Methods: Stenosis phantoms with different grades of stenosis (0%, 20%, 40%, 60%, 80%, and 100%; 5 mm inner vessel diameter) were produced using 3D printing (clear resin). Phantoms were imaged with four different concentrations of diluted Gd-DOTA representing established arterial concentrations after intravenous injection in humans. Samples were centrally positioned in a thorax phantom of 30 cm diameter filled with a custom-made liquid featuring dielectric properties of muscle tissue. MRI was performed on a 7 T whole-body system. 2D-gradient-echo sequences were acquired with an 8-channel transmit 16-channel receive (8 Tx / 16 Rx) cardiac array prototype coil with and without pTX mode. Measurements were compared to those obtained with identical scan parameters using a commercially available 1 Tx / 16 Rx single transmit coil (sTX). To assess reproducibility, measurements (n = 15) were repeated at different horizontal angles with respect to the B0-field. Results: B1-shimming and pTX markedly improved flip angle homogeneity across the thorax phantom yielding a distinctly increased signal-to-noise ratio (SNR) averaged over a whole slice relative to non-manipulated RF fields. Images without B1-shimming showed shading artifacts due to local B1+-field inhomogeneities, which hampered stenosis quantification in severe cases. In contrast, B1-shimming and pTX provided superior image homogeneity. Compared with a conventional sTX coil higher grade stenoses (60% and 80%) were graded significantly (p1-shimming and pTX than with the conventional sTX coil (inside the stenosis phantoms 14%, outside the phantoms 32%). Both full and half concentration (10.2 mM and 5.1 mM) of a conventional Gd-DOTA dose for humans were equally suitable for stenosis evaluation in this phantom study. Conclusions: B1-shimming and pTX at 7 T can distinctly improve image homogeneity and therefore provide considerably more accurate MR image analysis, which is beneficial for imaging of small vessel structures.
- 1 August 2021
- Published by Elsevier in Physica Medica
- Vol. 88, 65-70
Magnetic particle imaging for artifact-free imaging of intracranial flow diverter stents: A phantom study
- 1 August 2021
- Published by Elsevier in Physica Medica
- Vol. 88, 65-70
Magnetic particle imaging for artifact-free imaging of intracranial flow diverter stents: A phantom study
- 1 January 2021
- Published by Elsevier in Physica Medica
- Vol. 81, 210-214
Near real-time magnetic particle imaging for visual assessment of vascular stenosis in a phantom model
- 1 January 2021
- Published by Elsevier in Physica Medica
- Vol. 81, 210-214
Near real-time magnetic particle imaging for visual assessment of vascular stenosis in a phantom model
- 14 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 56 (11) , 1-6
Adjustable Hardware Lens for Traveling Wave Magnetic Particle Imaging
Magnetic Particle Imaging (MPI) is a promising tomographic technique for fast and sensitive visualization of superparamagnetic iron-oxide nanoparticles (SPIONs). Different types of MPI scanners have been presented in the past providing 2D as well as 3D data with different sizes of the field of view (FOV). With increasing FOVs, often the spatial resolution decreases. Traveling Wave MPI scanners provide the possibility to visualize the entire available FOV within the scanner at once with a good spatial resolution and a high temporal resolution. However, a more selective imaging process, such as scanning specific areas within the sample collecting more information, is of high interest. This can be performed by adjusting the sequences for signal acquisition, e.g., by modulation of the amplitude, to actively suppress signal generation in specific areas. Unfortunately, this method requires adaptation of the hardware. In this manuscript a novel approach for imaging specific areas within the FOV of a Traveling Wave MPI scanner is presented without specific hardware modifications. Furthermore, this technique offers the possibility to increase the resolution by up to 40 %, which reveals more details in this area, similar to a magnification effect.
- 14 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 56 (11) , 1-6
Adjustable Hardware Lens for Traveling Wave Magnetic Particle Imaging
Magnetic Particle Imaging (MPI) is a promising tomographic technique for fast and sensitive visualization of superparamagnetic iron-oxide nanoparticles (SPIONs). Different types of MPI scanners have been presented in the past providing 2D as well as 3D data with different sizes of the field of view (FOV). With increasing FOVs, often the spatial resolution decreases. Traveling Wave MPI scanners provide the possibility to visualize the entire available FOV within the scanner at once with a good spatial resolution and a high temporal resolution. However, a more selective imaging process, such as scanning specific areas within the sample collecting more information, is of high interest. This can be performed by adjusting the sequences for signal acquisition, e.g., by modulation of the amplitude, to actively suppress signal generation in specific areas. Unfortunately, this method requires adaptation of the hardware. In this manuscript a novel approach for imaging specific areas within the FOV of a Traveling Wave MPI scanner is presented without specific hardware modifications. Furthermore, this technique offers the possibility to increase the resolution by up to 40 %, which reveals more details in this area, similar to a magnification effect.
- Open Access
- 23 July 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (1) , 182-196
B0 shimming of the human heart at 7T
Purpose: Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B0‐field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed.Methods: The spatial B0‐field distribution in the heart was analyzed as well as temporal B0‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration‐based B0‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming.Results: The strongest B0‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B0‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents.Conclusion: Challenges in state‐of‐the‐art B0 shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.
- 23 July 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (1) , 182-196
Open AccessB0 shimming of the human heart at 7T
Purpose: Inhomogeneities of the static magnetic B0 field are a major limiting factor in cardiac MRI at ultrahigh field (≥ 7T), as they result in signal loss and image distortions. Different magnetic susceptibilities of the myocardium and surrounding tissue in combination with cardiac motion lead to strong spatio‐temporal B0‐field inhomogeneities, and their homogenization (B0 shimming) is a prerequisite. Limitations of state‐of‐the‐art shimming are described, regional B0 variations are measured, and a methodology for spherical harmonics shimming of the B0 field within the human myocardium is proposed.Methods: The spatial B0‐field distribution in the heart was analyzed as well as temporal B0‐field variations in the myocardium over the cardiac cycle. Different shim region‐of‐interest selections were compared, and hardware limitations of spherical harmonics B0 shimming were evaluated by calibration‐based B0‐field modeling. The role of third‐order spherical harmonics terms was analyzed as well as potential benefits from cardiac phase–specific shimming.Results: The strongest B0‐field inhomogeneities were observed in localized spots within the left‐ventricular and right‐ventricular myocardium and varied between systolic and diastolic cardiac phases. An anatomy‐driven shim region‐of‐interest selection allowed for improved B0‐field homogeneity compared with a standard shim region‐of‐interest cuboid. Third‐order spherical harmonics terms were demonstrated to be beneficial for shimming of these myocardial B0‐field inhomogeneities. Initial results from the in vivo implementation of a potential shim strategy were obtained. Simulated cardiac phase–specific shimming was performed, and a shim term‐by‐term analysis revealed periodic variations of required currents.Conclusion: Challenges in state‐of‐the‐art B0 shimming of the human heart at 7 T were described. Cardiac phase–specific shimming strategies were found to be superior to vendor‐supplied shimming.
- 1 April 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (4) , 045117
Parallel magnetic particle imaging
Magnetic Particle Imaging (MPI) is a promising tomographic method to visualize the distribution of superparamagnetic materials in three-dimensions. For encoding, a strong gradient represented by a field free point (FFP) or a field free line (FFL) is steered rapidly through the field of view (FOV), acquiring the signal successively. Conventional MPI scanners only provide a single FFP or FFL to sample the entire scan volume, which limits the size of the FOV and/or the temporal resolution. The alternative scanner concept of Traveling Wave MPI (TWMPI) uses a dynamic linear gradient array (dLGA) for dynamic FFP generation along the symmetry axis. The TWMPI scanner is capable of creating multiple FFPs simultaneously, and usually care is taken to locate only a single FFP in the desired FOV. In this manuscript, the concept of parallel MPI utilizing multiple FFPs simultaneously is introduced. For that, conceptual simulations are presented followed by reconstruction approaches for visualization of parallel MPI signals. In addition, an initial parallel MPI experiment with simultaneous acquisition of signals from two FFPs inside the FOV of the same scanner using two receive chains is demonstrated. This allows scanning a doubled FOV within the same acquisition time without sacrificing resolution compared to the standard TWMPI scanner.
- 1 April 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (4) , 045117
Parallel magnetic particle imaging
Magnetic Particle Imaging (MPI) is a promising tomographic method to visualize the distribution of superparamagnetic materials in three-dimensions. For encoding, a strong gradient represented by a field free point (FFP) or a field free line (FFL) is steered rapidly through the field of view (FOV), acquiring the signal successively. Conventional MPI scanners only provide a single FFP or FFL to sample the entire scan volume, which limits the size of the FOV and/or the temporal resolution. The alternative scanner concept of Traveling Wave MPI (TWMPI) uses a dynamic linear gradient array (dLGA) for dynamic FFP generation along the symmetry axis. The TWMPI scanner is capable of creating multiple FFPs simultaneously, and usually care is taken to locate only a single FFP in the desired FOV. In this manuscript, the concept of parallel MPI utilizing multiple FFPs simultaneously is introduced. For that, conceptual simulations are presented followed by reconstruction approaches for visualization of parallel MPI signals. In addition, an initial parallel MPI experiment with simultaneous acquisition of signals from two FFPs inside the FOV of the same scanner using two receive chains is demonstrated. This allows scanning a doubled FOV within the same acquisition time without sacrificing resolution compared to the standard TWMPI scanner.
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (6) , 2133-2139
Superspeed Bolus Visualization for Vascular Magnetic Particle Imaging
Magnetic Particle Imaging (MPI) is a fast imaging technique to visualize the distribution of superparamagnetic iron-oxide nanoparticles (SPIONs). For spatial encoding, a field free area is moved rapidly through the field of view (FOV) generating localized signal. Fast moving samples, e.g., a bolus of SPIONs traveling through the large veins in the human body carried by blood flow with velocities in the order of ~45 cm/s, cause temporal blurring in MPI measurements using common sequences and reconstruction techniques. This hampers the evaluation of dynamics of fast moving samples. In this manuscript, a first study on fast moving samples visualized within an MPI scanner is demonstrated. By optimizing parameters for imaging and reconstruction, the dynamics of a fast moving bolus at different velocities can be visualized with high temporal resolution without blurring artifacts.
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (6) , 2133-2139
Superspeed Bolus Visualization for Vascular Magnetic Particle Imaging
Magnetic Particle Imaging (MPI) is a fast imaging technique to visualize the distribution of superparamagnetic iron-oxide nanoparticles (SPIONs). For spatial encoding, a field free area is moved rapidly through the field of view (FOV) generating localized signal. Fast moving samples, e.g., a bolus of SPIONs traveling through the large veins in the human body carried by blood flow with velocities in the order of ~45 cm/s, cause temporal blurring in MPI measurements using common sequences and reconstruction techniques. This hampers the evaluation of dynamics of fast moving samples. In this manuscript, a first study on fast moving samples visualized within an MPI scanner is demonstrated. By optimizing parameters for imaging and reconstruction, the dynamics of a fast moving bolus at different velocities can be visualized with high temporal resolution without blurring artifacts.
- Open Access
- 2 September 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Magnetic Particle Imaging meets Computed Tomography: first simultaneous imaging
Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented.
- 2 September 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Open AccessMagnetic Particle Imaging meets Computed Tomography: first simultaneous imaging
Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented.
- 2 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (10) , 1-7
Micro-Traveling Wave Magnetic Particle Imaging—Sub-Millimeter Resolution With Optimized Tracer LS-008
Magnetic particle imaging (MPI) is a novel tomographic imaging method, which allows determining the distribution of superparamagnetic iron-oxide nanoparticles in three dimensions. So far, various MPI systems have been presented with each one emphasizing different scanner features such as large field of view (FOV) or high resolution. For imaging with both high resolution and a large FOV, the optimization and harmonization of hardware parameters as well as tracer material are key prerequisites. The traveling wave MPI (TWMPI) approach uses an array of electromagnets, which can provide a high magnetic field gradient for a high resolution as well as a mouse-sized FOV at the same time. In combination with the tracer LS-008, which is optimized for the MPI technique, a resolution in the sub-millimeter range can be achieved. In this paper, an optimized scanner is presented based on the TWMPI approach featuring a gradient strength up to almost 10 T/m in an FOV with a length of 45 mm providing a high resolution below 500 microns using the optimized LS-008 tracer.
- 2 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 55 (10) , 1-7
Micro-Traveling Wave Magnetic Particle Imaging—Sub-Millimeter Resolution With Optimized Tracer LS-008
Magnetic particle imaging (MPI) is a novel tomographic imaging method, which allows determining the distribution of superparamagnetic iron-oxide nanoparticles in three dimensions. So far, various MPI systems have been presented with each one emphasizing different scanner features such as large field of view (FOV) or high resolution. For imaging with both high resolution and a large FOV, the optimization and harmonization of hardware parameters as well as tracer material are key prerequisites. The traveling wave MPI (TWMPI) approach uses an array of electromagnets, which can provide a high magnetic field gradient for a high resolution as well as a mouse-sized FOV at the same time. In combination with the tracer LS-008, which is optimized for the MPI technique, a resolution in the sub-millimeter range can be achieved. In this paper, an optimized scanner is presented based on the TWMPI approach featuring a gradient strength up to almost 10 T/m in an FOV with a length of 45 mm providing a high resolution below 500 microns using the optimized LS-008 tracer.
- 27 May 2019
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 26 (4) , 512-519
Magnetic Particle Imaging–Guided Stenting
Purpose:To assess the feasibility of magnetic particle imaging (MPI) to guide stenting in a phantom model. Materials and Methods: MPI is a new tomographic imaging method based on the background-free magnetic field detection of a tracer agent composed of superparamagnetic iron oxide nanoparticles (SPIOs). All experiments were conducted on a custom-built MPI scanner (field of view: 29-mm diameter, 65-mm length; isotropic spatial resolution 1–1.5-mm). Stenosis phantoms (n=3) consisted of polyvinyl chloride (PVC) tubes (8-mm inner diameter) prepared with centrally aligned cable binders to form a ~50% stenosis. A dedicated image reconstruction algorithm allowed precise tracking of endovascular instruments at 8 frames/s with a latency time of ~115 ms. A custom-made MPI-visible lacquer was used to manually label conventional guidewires, balloon catheters, and stainless steel balloon-expandable stents. Vascular stenoses were visualized by injecting a diluted SPIO tracer (ferucarbotran, 10 mmol iron/L) into the vessel phantoms. Balloon angioplasty and stent placement were performed by inflating balloon catheters and stent delivery balloons with diluted ferucarbotran. Results: After deployment of the stent, the markers on its ends were clearly visible. The applied lacquer markers were thin enough to not relevantly alter gliding properties of the devices while withstanding friction during the experiments. Placing an optimized flexible lacquer formulation on the preexisting radiopaque stent markers provided enough stability to withstand stent expansion. Final MPA confirmed successful stenosis treatment, facilitated by the disappearance of the lacquer markers on the stent due to differences in SPIO concentration. Thus, the in-stent lumen could be visualized without interference by the signal from the markers. Conclusion: Near real-time visualization of MPI-guided stenting of stenoses in a phantom model is feasible. Optimized MPI-visible markers can withstand the expansion process of stents.
- 27 May 2019
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 26 (4) , 512-519
Magnetic Particle Imaging–Guided Stenting
Purpose:To assess the feasibility of magnetic particle imaging (MPI) to guide stenting in a phantom model. Materials and Methods: MPI is a new tomographic imaging method based on the background-free magnetic field detection of a tracer agent composed of superparamagnetic iron oxide nanoparticles (SPIOs). All experiments were conducted on a custom-built MPI scanner (field of view: 29-mm diameter, 65-mm length; isotropic spatial resolution 1–1.5-mm). Stenosis phantoms (n=3) consisted of polyvinyl chloride (PVC) tubes (8-mm inner diameter) prepared with centrally aligned cable binders to form a ~50% stenosis. A dedicated image reconstruction algorithm allowed precise tracking of endovascular instruments at 8 frames/s with a latency time of ~115 ms. A custom-made MPI-visible lacquer was used to manually label conventional guidewires, balloon catheters, and stainless steel balloon-expandable stents. Vascular stenoses were visualized by injecting a diluted SPIO tracer (ferucarbotran, 10 mmol iron/L) into the vessel phantoms. Balloon angioplasty and stent placement were performed by inflating balloon catheters and stent delivery balloons with diluted ferucarbotran. Results: After deployment of the stent, the markers on its ends were clearly visible. The applied lacquer markers were thin enough to not relevantly alter gliding properties of the devices while withstanding friction during the experiments. Placing an optimized flexible lacquer formulation on the preexisting radiopaque stent markers provided enough stability to withstand stent expansion. Final MPA confirmed successful stenosis treatment, facilitated by the disappearance of the lacquer markers on the stent due to differences in SPIO concentration. Thus, the in-stent lumen could be visualized without interference by the signal from the markers. Conclusion: Near real-time visualization of MPI-guided stenting of stenoses in a phantom model is feasible. Optimized MPI-visible markers can withstand the expansion process of stents.