A semi-quantitative dipstick assay for microcystin
- 24 March 2009
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 394 (3) , 863-869
Abstract
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.Keywords
This publication has 16 references indexed in Scilit:
- A highly specific immunoassay for microcystin-LR detection based on a monoclonal antibodyAnalytica Chimica Acta, 2007
- Generation and characterization of polyclonal antibodies against microcystins—Application to immunoassays and immunoaffinity sample preparation prior to analysis by liquid chromatography and UV detectionTalanta, 2006
- A comprehensive immunoassay for the detection of microcystins in waters based on polyclonal antibodiesAnalytica Chimica Acta, 2006
- Development of a highly sensitive inhibition immunoassay for microcystin-LRAnalytica Chimica Acta, 2004
- Algengifte im WasserNachrichten aus der Chemie, 2002
- Development of a Direct Competitive Microcystin Immunoassay of Broad SpecificityAnalytical Sciences, 2001
- Highly sensitive immunoassay based on a monoclonal antibody specific for [4-arginine]microcystinsAnalytica Chimica Acta, 2001
- No chronic oral toxicity of a low dose of microcystin-LR, a cyanobacterial hepatotoxin, in female BALB/c miceEnvironmental Toxicology, 1999
- Small colloidal gold conjugated to fab fragments or to immunoglobulin g as high‐resolution labels for electron microscopy: A technical overviewJournal of Electron Microscopy Technique, 1990
- Fundamental study on latex reagents for agglutination testsBiomaterials, 1989