Effects of Iopamidol-370 Versus Iodixanol-320 on Coronary Contrast, Branch Depiction, and Heart Rate Variability in Dual-Source Coronary MDCT Angiography
Authors:
- 1 September 2011
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 197 (3) , W445-W451
Abstract
OBJECTIVE. The purpose of this article is to assess whether iopamidol-370 provides superior vascular contrast of the coronaries and depiction of anatomic detail without affecting heart rate and beat-to-beat variability during coronary dual-source MDCT compared with iodixanol-320. SUBJECTS AND METHODS. In this prospective trial, coronary CT angiography was performed on 60 adult patients using either iopamidol-370 or iodixanol-320. Cohorts were matched by age, habitus, sex, and baseline heart rate, with cohort sizes determined by power analysis. All studies were performed on a dual-source MDCT scanner with retrospective ECG-gating utilizing automatic pitch adjustment. Data assessment focused on heart rate variability during contrast administration statistically evaluated as Student t test comparisons within and between cohorts, coronary contrast-to-noise ratio analysis of the main coronary arteries utilizing Student t test comparisons between cohorts, and coronary branch depiction and distribution analysis in dual-reader consensus decisions between cohorts. RESULTS. Thirty patients matched for age, habitus, sex, and heart rate were evaluated in each cohort. ECG analyses found a statistically significant (p = 0.013) decrease in heart rate during administration of iodixanol-320. Beat-to-beat variations, expressed as coefficient of variation, within and among cohorts were low (coefficient of variation, < 0.05). Contrast-to-noise ratio was significantly increased for iopamidol-370 versus iodixanol-320 (aortic root, p = 0.021; left main, p = 0.032; left anterior descending, p = 0.033; left circumflex, p = 0.039; and right, p = 0.009). Analysis of coronary branch visualization revealed improved depiction for iopamidol-370 compared with iodixanol-320. CONCLUSION. Iopamidol-370, with its higher iodine concentration, provided greater vascular contrast of the arterial coronary tree and improved depiction of anatomic detail without significantly impacting cardiac heart rate during coronary MDCT imaging, as compared with iodixanol-320.Keywords
This publication has 27 references indexed in Scilit:
- Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggeringThe International Journal of Cardiovascular Imaging, 2010
- Dual-Source versus 64-Section CT Coronary Angiography at Lower Heart Rates: Comparison of Accuracy and Radiation DoseRadiology, 2009
- Low-Dose Coronary CT Angiography With Prospective ECG Triggering: Validation of a Contrast Material Protocol Adapted to Body Mass IndexAmerican Journal of Roentgenology, 2009
- Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiographyEuropean Radiology, 2009
- Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weightClinical Radiology, 2008
- Saline Flush Effect for Enhancement of Aorta and Coronary Arteries at Multidetector CT Coronary AngiographyRadiology, 2008
- Optimization of Contrast Material Administration for Electrocardiogram-gated Computed Tomographic Angiography of the ChestJournal of Computer Assisted Tomography, 2007
- Higher Intracoronary Attenuation Improves Diagnostic Accuracy in MDCT Coronary AngiographyAmerican Journal of Roentgenology, 2006
- Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart ratesThe International Journal of Cardiovascular Imaging, 2005
- Automatic Exposure Control Techniques for Individual Dose AdaptationRadiology, 2005