Microbiological indoor air quality and associated factors in private clinics of Harar Town, Eastern Ethiopia
Open Access
- 2 December 2024
- journal article
- research article
- Published by Mattioli1885 in Multidisciplinary Respiratory Medicine
- Vol. 19 (Vol. 19 (2)
Abstract
Background: Indoor air pollution, including airborne microorganisms, can cause allergies, respiratory diseases, and immune-toxic diseases. Sneezing generates millions of airborne microbial infections, and ventilation sources alter microbial communities. Few studies exist in developing countries, including Ethiopia, and Harar Town. The aim is to assess microbial indoor air quality and associated factors among private clinics, Harar town, Eastern Ethiopia. Methodology: A cross-sectional study was conducted on 260 private clinic rooms in Harar town, using a systematic random sampling method and passive air sampling. Data was collected using the settle plate method and an observation checklist. Bivariate and multivariate analysis was performed using binary logistic regression, with a P-value of <0.05 considered statistically significant. Result: The minimum and maximum bacterial loads were 3933 CFU/m3 and 92 CFU/m3 respectively. Based on the pollution degree of the European Commission, the Mean bacterial load (904 CFU/m3) was at higher bacterial load. The highest, lowest, and mean fungal loads were 1967 CFU/m3, 9 CFU/m3 and 401 CFU/m3 respectively. Temperature of 28 °C (AOR = 1.23, P = 0.03, and 95% CI = 1.51, 2.02) were significantly associated with bacterial indoor air quality. Relative humidity of treatment rooms (AOR = 1.87, p = 0.02, and 95% CI = 1.21, 3.09) had an association with bacterial loads. The clinic treatment rooms with a recorded temperature 28 °C (AOR = 0.41, p = 0.04, and 95% CI = 0.31, 0.78) were 59% less likely to comply with the fungal standards compared to rooms having a temperature of 25–28 °C. The clinic rooms with a relative humidity of 60% in the treatment rooms. Conclusion: Private clinics in Harar had a moderate fungal load and a higher indoor air bacterial concentration when compared to different indoor air standards. Temperature, humidity, inadequate ventilation and the presence of unsanitary attached toilets are some variables associated with microbial loads.Keywords
This publication has 21 references indexed in Scilit:
- Determination of the indoor air bacterial profile in Jimma University Specialized Hospital, Southwest EthiopiaSage Open Medicine, 2022
- Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern EthiopiaPLOS ONE, 2022
- Assessment of microbiological indoor air quality in a public hospital in the city of Agadir, MoroccoPeriodicum Biologorum, 2021
- Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schoolsMultidisciplinary Respiratory Medicine, 2019
- High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest EthiopiaMultidisciplinary Respiratory Medicine, 2016
- Architectural Design Drives the Biogeography of Indoor Bacterial CommunitiesPLOS ONE, 2014
- Human Occupancy as a Source of Indoor Airborne BacteriaPLOS ONE, 2012
- Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC systemEnvironmental Monitoring and Assessment, 2009
- Physiological Daily Inhalation Rates for Free-Living Individuals Aged 1 Month to 96 Years, Using Data from Doubly Labeled Water Measurements: A Proposal for Air Quality Criteria, Standard Calculations and Health Risk AssessmentHuman and Ecological Risk Assessment: An International Journal, 2006
- Microbiological Control of Airborne Contamination in HospitalsIndoor and Built Environment, 2006