Salie Mulat Endalew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Salie Mulat Endalew has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bealemlay Abebe Melake
School of Environmental Health Science, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia
3 shared publications - Tamagnu Sintie Alamirew
School of Environmental Health Science, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia
3 shared publications - Liku Muche Temesgen
School of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia
2 shared publications - Sina Temesgen Tolera
College of Health and Medical Sciences, Haramaya University, Harar City, Ethiopia
2 shared publications Abraham Geremew Gawo
School of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia
1 shared publicationDechasa Adare Mengistu
School of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia
1 shared publication
Latest Publications
- 12 December 2024
- Published by Springer Nature in Sustainable Water Resources Management
- Vol. 11 (1) , 1-10
Biological indicators integration with physicochemical parameters for water quality assessment of Lake Haramaya, Eastern Ethiopia
- 12 December 2024
- Published by Springer Nature in Sustainable Water Resources Management
- Vol. 11 (1) , 1-10
Biological indicators integration with physicochemical parameters for water quality assessment of Lake Haramaya, Eastern Ethiopia
- Open Access
- 2 December 2024
- Published by Mattioli1885 in Multidisciplinary Respiratory Medicine
- Vol. 19 (Vol. 19 (2)
Microbiological indoor air quality and associated factors in private clinics of Harar Town, Eastern Ethiopia
Background: Indoor air pollution, including airborne microorganisms, can cause allergies, respiratory diseases, and immune-toxic diseases. Sneezing generates millions of airborne microbial infections, and ventilation sources alter microbial communities. Few studies exist in developing countries, including Ethiopia, and Harar Town. The aim is to assess microbial indoor air quality and associated factors among private clinics, Harar town, Eastern Ethiopia. Methodology: A cross-sectional study was conducted on 260 private clinic rooms in Harar town, using a systematic random sampling method and passive air sampling. Data was collected using the settle plate method and an observation checklist. Bivariate and multivariate analysis was performed using binary logistic regression, with a P-value of <0.05 considered statistically significant. Result: The minimum and maximum bacterial loads were 3933 CFU/m3 and 92 CFU/m3 respectively. Based on the pollution degree of the European Commission, the Mean bacterial load (904 CFU/m3) was at higher bacterial load. The highest, lowest, and mean fungal loads were 1967 CFU/m3, 9 CFU/m3 and 401 CFU/m3 respectively. Temperature of 28 °C (AOR = 1.23, P = 0.03, and 95% CI = 1.51, 2.02) were significantly associated with bacterial indoor air quality. Relative humidity of treatment rooms (AOR = 1.87, p = 0.02, and 95% CI = 1.21, 3.09) had an association with bacterial loads. The clinic treatment rooms with a recorded temperature 28 °C (AOR = 0.41, p = 0.04, and 95% CI = 0.31, 0.78) were 59% less likely to comply with the fungal standards compared to rooms having a temperature of 25–28 °C. The clinic rooms with a relative humidity of 60% in the treatment rooms. Conclusion: Private clinics in Harar had a moderate fungal load and a higher indoor air bacterial concentration when compared to different indoor air standards. Temperature, humidity, inadequate ventilation and the presence of unsanitary attached toilets are some variables associated with microbial loads.
- 2 December 2024
- Published by Mattioli1885 in Multidisciplinary Respiratory Medicine
- Vol. 19 (Vol. 19 (2)
Open AccessMicrobiological indoor air quality and associated factors in private clinics of Harar Town, Eastern Ethiopia
Background: Indoor air pollution, including airborne microorganisms, can cause allergies, respiratory diseases, and immune-toxic diseases. Sneezing generates millions of airborne microbial infections, and ventilation sources alter microbial communities. Few studies exist in developing countries, including Ethiopia, and Harar Town. The aim is to assess microbial indoor air quality and associated factors among private clinics, Harar town, Eastern Ethiopia. Methodology: A cross-sectional study was conducted on 260 private clinic rooms in Harar town, using a systematic random sampling method and passive air sampling. Data was collected using the settle plate method and an observation checklist. Bivariate and multivariate analysis was performed using binary logistic regression, with a P-value of <0.05 considered statistically significant. Result: The minimum and maximum bacterial loads were 3933 CFU/m3 and 92 CFU/m3 respectively. Based on the pollution degree of the European Commission, the Mean bacterial load (904 CFU/m3) was at higher bacterial load. The highest, lowest, and mean fungal loads were 1967 CFU/m3, 9 CFU/m3 and 401 CFU/m3 respectively. Temperature of 28 °C (AOR = 1.23, P = 0.03, and 95% CI = 1.51, 2.02) were significantly associated with bacterial indoor air quality. Relative humidity of treatment rooms (AOR = 1.87, p = 0.02, and 95% CI = 1.21, 3.09) had an association with bacterial loads. The clinic treatment rooms with a recorded temperature 28 °C (AOR = 0.41, p = 0.04, and 95% CI = 0.31, 0.78) were 59% less likely to comply with the fungal standards compared to rooms having a temperature of 25–28 °C. The clinic rooms with a relative humidity of 60% in the treatment rooms. Conclusion: Private clinics in Harar had a moderate fungal load and a higher indoor air bacterial concentration when compared to different indoor air standards. Temperature, humidity, inadequate ventilation and the presence of unsanitary attached toilets are some variables associated with microbial loads.
- Open Access
- 4 November 2024
- Published by Mattioli1885 in Multidisciplinary Respiratory Medicine
- Vol. 19 (Vol. 19 (2)
Indoor air bacterial quality and associated factors in prison inmate cells of East Hararghe Zone and Harari Regional State, Eastern Ethiopia
Background: Bacterial indoor air load refers to the level of bacteria within and around dwellings and other structures. Pathogens, bacterial cell fragments, and bacterial organisms’ byproducts can all pose major issues indoors, especially in prison inmate cells. However, there is lack of data on bacterial load and contributing factors in the East Hararghe zone and Harari regional state. The lack of studies on microbiological indoor air quality in prisons with contributing factors will therefore be filled by this investigation. Objectives: The study aimed to assess bacterial indoor air load and contributing factors in prison inmate cells from October 1 to October 30, 2020. Methodology: An institutional cross-sectional study was employed. All of the prisons in the East Hararghe zone and the Harari regional state served as the study’s and source population. 62 prison cells were used in the investigation. Samples were obtained using the passively settling plate technique. The data were evaluated through the use of SPSS statistical software, Excel, and the statistical procedures of ANOVA, correlation, and chi-square test. Results: The maximum and minimum bacterial loads, were recorded at 8:00 am (3027 CFU/m3) and 2:00 pm (1048 (CFU/m3) respectively. The correlation between the temperature and bacterial load was strongly positive (r = 0.680, p = 0.047), and the correlation of the moisture content and bacterial load was strongly negative (r = -0.671, p = 0.039). Conclusion: The levels of bacteria were higher than the guideline (2000 CFU/m3). While the relative humidity of indoor air was negatively correlated with bacterial load, temperature and bacterial load were significantly positively correlated. Harari regional state and East Hararghe zone prison commissions should be alarmed to alleviate these problems. The building standards need to be completely updated to the latest standards.
- 4 November 2024
- Published by Mattioli1885 in Multidisciplinary Respiratory Medicine
- Vol. 19 (Vol. 19 (2)
Open AccessIndoor air bacterial quality and associated factors in prison inmate cells of East Hararghe Zone and Harari Regional State, Eastern Ethiopia
Background: Bacterial indoor air load refers to the level of bacteria within and around dwellings and other structures. Pathogens, bacterial cell fragments, and bacterial organisms’ byproducts can all pose major issues indoors, especially in prison inmate cells. However, there is lack of data on bacterial load and contributing factors in the East Hararghe zone and Harari regional state. The lack of studies on microbiological indoor air quality in prisons with contributing factors will therefore be filled by this investigation. Objectives: The study aimed to assess bacterial indoor air load and contributing factors in prison inmate cells from October 1 to October 30, 2020. Methodology: An institutional cross-sectional study was employed. All of the prisons in the East Hararghe zone and the Harari regional state served as the study’s and source population. 62 prison cells were used in the investigation. Samples were obtained using the passively settling plate technique. The data were evaluated through the use of SPSS statistical software, Excel, and the statistical procedures of ANOVA, correlation, and chi-square test. Results: The maximum and minimum bacterial loads, were recorded at 8:00 am (3027 CFU/m3) and 2:00 pm (1048 (CFU/m3) respectively. The correlation between the temperature and bacterial load was strongly positive (r = 0.680, p = 0.047), and the correlation of the moisture content and bacterial load was strongly negative (r = -0.671, p = 0.039). Conclusion: The levels of bacteria were higher than the guideline (2000 CFU/m3). While the relative humidity of indoor air was negatively correlated with bacterial load, temperature and bacterial load were significantly positively correlated. Harari regional state and East Hararghe zone prison commissions should be alarmed to alleviate these problems. The building standards need to be completely updated to the latest standards.