Abstract
Evaluation of the new shift bump magnet for the replacement of the J-PARC RCS confirmed a magnetic field waveform is different from the excitation current waveform. This reason is the eddy current effect due to the fast trapezoidal excitation pattern of about 1.5 ms. The same result was confirmed by OPERA-3D. The magnetic field waveform with less than 1.0 % fluctuations at flat-top necessary to realize a highly accurate injection beam orbit that suppresses the radiation of the device due to beam loss. We evaluated the effectiveness of the dynamic magnetic field analysis of OPERA-3D in comparison with the measurement results. The agreement of 0.06 % deviation in the magnetic field distribution, the effect of eddy currents on the magnetic field wave-form, and the potential of the analysis software for system design were confirmed. We also calculated the amount of heat generated by the bump magnet coil and the necessary measures for operation. Furthermore, we verified probes that can accurately evaluate pulse excitation waveforms.

This publication has 8 references indexed in Scilit: