MSMoe Sugita

Moe Sugita

*This is an algorithmically generated author record based on publicly available information.

Moe Sugita has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Model-Based Development of Pulsed Electromagnets for Accelerators by Simulation

    by T. Takayanagi, T. Ueno, K. Horino, M. Sugita, Y. Fuwa, Shinozaki

    In accelerators, pulsed electromagnets are used for beam injections, extractions, and localization of beam losses. Compared to DC electromagnets, pulsed electromagnets generate powerful magnetic fields instantaneously and produce Joule heat only for a short time, making them more energy efficient. If the design of pulse electromagnets and power supplies becomes easier, they are expected to have a wide range of applications in sustainable accelerators. The design of pulsed electromagnets requires three-dimensional transient magnetic field analysis that takes into account eddy currents and skin effects, but high-precision design can be achieved by using analysis software such as OPERA-3D. On the other hand, in the design of pulsed power supplies, it is necessary to treat the load impedance as a time-varying model, but in many cases, actual measurement data is insufficient. Conventionally, electromagnets and power supplies have been analyzed separately, so there was a risk of problems being discovered during post-completion evaluation tests. To address this issue, we propose model-based development (MBD) that enables integrated analysis of both components. In this study, we evaluated the following two integrated analysis approaches: (1) an MBD method that links OPERA-3D's transient analysis model with its circuit editor function, and (2) an MBD method that combines OPERA-3D's analysis results with circuit simulation in MATLAB/Simulink. The introduction of MBD is expected to reduce power-on test time and the number of prototypes, leading to reduced development costs and shorter development times. This presentation will report on preliminary results of an evaluation of MBD implementation.

  • Development of a Fast-Rising Short-Pulse High-Voltage Power Supply Using SiC-MOSFETs for the J-PARC Kicker System

    by Tomohiro Takayanagi, Koki Horino, Tomoaki Ueno, Moe Sugita, Yasuhiro Fuwa, Shinichi Shinozaki, Ayato Ono, Akira Tokuchi, Naoya Ikoma, Hiroaki Kamezaki

    We have been developing a semiconductor switch power supply using silicon carbide metal–oxide–semiconductor field-effect transistors (SiC-MOSFETs) as an alternative to conventional discharge tube thyratron-type switch power supplies. The newly developed power supply, based on the linear transformer driver (LTD) circuit system, delivers 40-kV, 2-kA, and 1.2- $\mu $ s pulsewidth at 25 Hz. This power supply has achieved performance that allows replacing the current kicker power supply using the thyratron switch in the Japan Proton Accelerator Research Complex (J-PARC) 3-GeV rapid cycling synchrotron (RCS). The specifications of the developed LTD pulse power supply circuit for SiC-MOSFETs, the corona-free high-voltage section, and the results of power saving and miniaturization will be reported.

  • Development of Precise Shimming Technique With Materials Having Low Saturation Magnetization

    by K. Sasaki, M. Sugita, M. Abe, H. Iinuma, C. Ogane, T. Mibe, K. Shimomura, T. Ogitsu

    Magnetic field shimming using low saturation magnetization material was tested to realize spatial magnetic field homogeneity of less than 1 ppm. The magnetic moment per unit mass were measured for three candidates, that is, Nickel, magnetic fluid and magnetic putty, and it was verified that those have low magnetic moments suitable for precise shimming below 1 ppm. The magnetic shimming test was performed using MRI magnet for MuSEUM experiment at 1.2 T with iron plates, Ni thin plates and magnetic putty. The magnetic shimming with iron plates was conducted employing the two step shimming scheme, and the homogeneity could be reached to 0.29 ppm peak-to-peak (ppm $_\text{pp}$ ) after six shimming trials. Then, the precise shimming was carried out with Ni thin plates and magnetic putty, and the homogeneity could be reached to 0.16 ppm peak-to-peak with Nickel and 0.17 ppm $_\text{pp}$ with magnetic putty. No deformation of putty in the magnetic field was observed even after two months. The magnetic field monitoring for two months showed that magnetic field strength and homogeneity largely depended on the temperature, and the temperature of the magnet room has to be controlled within $\pm$ 0.35 degC under the circumference condition of the shimming test in order to keep the magnetic field change and the homogeneity within $\pm$ 0.1 ppm. In addition, it is showed that the refilling of LHe in the MuSEUM magnet system should be performed once per 29 days The practical implementation method for magnetic putty was suggested for the existing magnet system by using plastic spacers with holes.


  • Evaluation of Eddy Currents Dependent on Excitation Pattern in Design of Pulse Electromagnets

    by Tomohiro Takayanagi, Moe Sugita, Tomoaki Ueno, Koki Horino, Ayato Ono, Kazami Yamamoto, Michikazu Kinsho

    Evaluation of the new shift bump magnet for the replacement of the J-PARC RCS confirmed a magnetic field waveform is different from the excitation current waveform. This reason is the eddy current effect due to the fast trapezoidal excitation pattern of about 1.5 ms. The same result was confirmed by OPERA-3D. The magnetic field waveform with less than 1.0 % fluctuations at flat-top necessary to realize a highly accurate injection beam orbit that suppresses the radiation of the device due to beam loss. We evaluated the effectiveness of the dynamic magnetic field analysis of OPERA-3D in comparison with the measurement results. The agreement of 0.06 % deviation in the magnetic field distribution, the effect of eddy currents on the magnetic field wave-form, and the potential of the analysis software for system design were confirmed. We also calculated the amount of heat generated by the bump magnet coil and the necessary measures for operation. Furthermore, we verified probes that can accurately evaluate pulse excitation waveforms.