Faster algorithms to measure visual field using the variational Bayes linear regression model in glaucoma: comparison with SITA-Fast
- 1 March 2022
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 107 (7) , 946-952
Abstract
Aims To compare the visual field (VF) test results measured with the Swedish Interactive Threshold Algorithm Fast (SITA-Fast) and newly developed variational Bayes linear regression visual field (VBLR-VF) Fast or VBLR-VF Fast+. Method Of 65 patients with glaucoma, 31 eyes of 31 patients performed VBLR-VF Fast and SITA-Fast, and 34 eyes of 34 patients performed VBLR-VF Fast+ and SITA-Fast on the same day and iterated the same procedures within 6 months using the 24–2 test grid in the current prospective study. Global index (mean deviation and pattern SD), pointwise retinal sensitivity, test duration and reliability index (fixation loss, false positive and false negative) were compared between SITA-Fast and VBLR-VF Fast or VBLR-VF Fast+. Results Global indices were not significantly different between SITA-Fast and VBLR-VF Fast or VBLR-VF Fast+. There was no significant difference in the pointwise retinal sensitivity between the SITA-Fast and VBLR-VF Fast algorithms at the first visit, while the VBLR-VF Fast algorithm was approximately 1 dB higher compared to the SITA-Fast algorithm at the second visit. Test duration was reduced by approximately 30 s (10%) with VBLR-VF Fast and by approximately 80 s (30%) with VBLR-VF Fast+ compared with to SITA-Fast (pConclusion Both VBLR-VF Fast and VBLR-VF Fast+ considerably reduced the test durations. Although there was a marginal difference in the pointwise retinal sensitivities, global indices were almost interchangeable between the VBLR-VF Fast and SITA-Fast.Keywords
Funding Information
- University of Tokyo Gap Fund Program (NA)
- Ministry of Education, Culture, Sports, Science, and Technology of Japan (00768351, 18KK0253, 19H01114, 25861618, 26462679, API)
This publication has 24 references indexed in Scilit:
- Swedish Interactive Threshold Algorithm for central visual field defects unrelated to nerve fiber layerGraefe's Archive for Clinical and Experimental Ophthalmology, 2015
- Role of Visual Field Reliability Indices in Ruling Out GlaucomaJAMA Ophthalmology, 2015
- A New Approach to Measure Visual Field Progression in Glaucoma Patients Using Variational Bayes Linear RegressionInvestigative Ophthalmology & Visual Science, 2014
- An Objective Evaluation of Gaze Tracking in Humphrey Perimetry and the Relation With the Reproducibility of Visual Fields: A Pilot Study in GlaucomaInvestigative Ophthalmology & Visual Science, 2014
- A Prospective Three-year Study of Response Properties of Normal Subjects and Patients during Automated PerimetryOphthalmology, 1993
- Pseudo-loss of Fixation in Automated PerimetryOphthalmology, 1991
- Screening for Glaucomatous Visual Field LossOphthalmology, 1990
- The influence of the learning effect on automated perimetry in patients with suspected glaucomaActa Ophthalmologica, 1989
- Assessing the Utility of Reliability Indices for Automated Visual FieldsOphthalmology, 1989
- AN AUTOMATIC STATIC PERIMETER, DESIGN AND PILOT STUDYActa Ophthalmologica, 1975