Kazunori Hirasawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazunori Hirasawa has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Murata
Department of Ophthalmology, National Center for Global Health and Medicine
28 shared publicationsNobuyuki Shoji
Ophthalmology, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan
27 shared publications- Ryo Asaoka
Affiliations Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka, Japan, Seirei Christopher University, Hamamatsu, Shizuoka, Japan, The Graduate School for the Creation of New Photonics Industries, Shizuoka, Japan, Organization for Innovation and Social Collaboration, National University Corporation Shizuoka University, Hamamatsu, Shizuoka, Japan
21 shared publications Masato Matsuura
Department of Ophthalmology, The University of Tokyo, Tokyo, Japan
12 shared publicationsMieko Yanagisawa
Department of Ophthalmology, The University of Tokyo, Tokyo, Japan
8 shared publications- Nobuyuki Shoji
Department of Ophthalmology, Kitasato University School of Medicine, Kanagawa, Japan
8 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by BMJ in BMJ Open Ophthalmology
- Vol. 11 (3) , e002987
Changes in ocular blood flow and haemodynamic waveform parameters following trabeculectomy
Objectives: To evaluate postoperative changes in ocular blood flow velocity and waveform parameters measured by laser speckle flowgraphy (LSFG) following trabeculectomy (TLE) in patients with glaucoma. Methods and analysis: This retrospective study included 80 eyes of 80 patients with glaucoma who underwent TLE and underwent LSFG examinations before and at 1, 3 and 6 months after surgery. LSFG-derived blood flow velocity parameters (mean blur rate (MBR) in MBR of vascular area (MV) and MBR of tissue area (MT), area ratio of blood speed and vascular cloudiness) and waveform parameters (blowout time, blowout score (BOS), skew, acceleration time index, rising rate, falling rate, flow acceleration index (FAI), resistivity index (RI) and fluctuation) were longitudinally evaluated using linear mixed-effects models. Results: Intraocular pressure (IOP) significantly decreased from 18.3 mm Hg preoperatively to 10.1, 10.0 and 9.9 mm Hg at 1, 3 and 6 months after TLE, respectively (all p<0.01). MV significantly decreased at all postoperative time points (all p<0.01), whereas MT showed a mild decrease only at 6 months (p=0.023). Among waveform parameters, BOS significantly increased postoperatively (all p<0.05), whereas FAI, RI and fluctuation significantly decreased at all postoperative time points (all p<0.01). IOP measured at each visit was independently associated with FAI and fluctuation, whereas age, mean deviation (MD) and axial length (AL) were associated with selected blood flow velocity and waveform parameters. Conclusion: These findings suggest that postoperative changes in ocular haemodynamics reflect the combined influence of postoperative IOP, patient age, MD and AL.
- 1 July 2026
- Published by BMJ in BMJ Open Ophthalmology
- Vol. 11 (3) , e002987
Open AccessChanges in ocular blood flow and haemodynamic waveform parameters following trabeculectomy
Objectives: To evaluate postoperative changes in ocular blood flow velocity and waveform parameters measured by laser speckle flowgraphy (LSFG) following trabeculectomy (TLE) in patients with glaucoma. Methods and analysis: This retrospective study included 80 eyes of 80 patients with glaucoma who underwent TLE and underwent LSFG examinations before and at 1, 3 and 6 months after surgery. LSFG-derived blood flow velocity parameters (mean blur rate (MBR) in MBR of vascular area (MV) and MBR of tissue area (MT), area ratio of blood speed and vascular cloudiness) and waveform parameters (blowout time, blowout score (BOS), skew, acceleration time index, rising rate, falling rate, flow acceleration index (FAI), resistivity index (RI) and fluctuation) were longitudinally evaluated using linear mixed-effects models. Results: Intraocular pressure (IOP) significantly decreased from 18.3 mm Hg preoperatively to 10.1, 10.0 and 9.9 mm Hg at 1, 3 and 6 months after TLE, respectively (all p<0.01). MV significantly decreased at all postoperative time points (all p<0.01), whereas MT showed a mild decrease only at 6 months (p=0.023). Among waveform parameters, BOS significantly increased postoperatively (all p<0.05), whereas FAI, RI and fluctuation significantly decreased at all postoperative time points (all p<0.01). IOP measured at each visit was independently associated with FAI and fluctuation, whereas age, mean deviation (MD) and axial length (AL) were associated with selected blood flow velocity and waveform parameters. Conclusion: These findings suggest that postoperative changes in ocular haemodynamics reflect the combined influence of postoperative IOP, patient age, MD and AL.
- 11 June 2026
- Published by Taylor & Francis in Current Eye Research
- Vol. 51 (8) , 1-6
Usefulness of the Entropy of the Bayesian Posterior Distribution of the Threshold to Assess the Reliability of Measured Visual Field
To investigate the association between reliability of visual field (VF) and the entropy of the Bayesian posterior distribution of the threshold. Subjects were comprised of 122 eyes of 73 patients with primary open-angle glaucoma. The VF was measured using the newly developed variational Bayes linear regression visual field (VBLR-VF) twice within 3 months. The likelihood of this final probability distribution of the thresholds in the measured VF was calculated (Entropy index). The mean absolute error (MAE) of the total deviation (TD) values of the test-retest VFs was measured, and its relationship to fixation losses (FLs), false positives (FPs), false negatives (FNs), and the Entropy index (average of the 2 VFs) was investigated. In addition, the association between the difference in the mean deviation (MD; between 2 VFs) and the difference in the Entropy index (between 2 VFs) was investigated. The Entropy index was significantly associated with FL, FP, and FN, as well as with the MAE (p < .001). Furthermore, the difference in the Entropy index was significantly negatively associated with the difference in MD (p < .001). The Entropy index was significantly associated with FL, FP, FN, and test-retest reproducibility. In addition, a higher Entropy index was associated with advanced VF loss, potentially indicating lower test reliability.
- 11 June 2026
- Published by Taylor & Francis in Current Eye Research
- Vol. 51 (8) , 1-6
Usefulness of the Entropy of the Bayesian Posterior Distribution of the Threshold to Assess the Reliability of Measured Visual Field
To investigate the association between reliability of visual field (VF) and the entropy of the Bayesian posterior distribution of the threshold. Subjects were comprised of 122 eyes of 73 patients with primary open-angle glaucoma. The VF was measured using the newly developed variational Bayes linear regression visual field (VBLR-VF) twice within 3 months. The likelihood of this final probability distribution of the thresholds in the measured VF was calculated (Entropy index). The mean absolute error (MAE) of the total deviation (TD) values of the test-retest VFs was measured, and its relationship to fixation losses (FLs), false positives (FPs), false negatives (FNs), and the Entropy index (average of the 2 VFs) was investigated. In addition, the association between the difference in the mean deviation (MD; between 2 VFs) and the difference in the Entropy index (between 2 VFs) was investigated. The Entropy index was significantly associated with FL, FP, and FN, as well as with the MAE (p < .001). Furthermore, the difference in the Entropy index was significantly negatively associated with the difference in MD (p < .001). The Entropy index was significantly associated with FL, FP, FN, and test-retest reproducibility. In addition, a higher Entropy index was associated with advanced VF loss, potentially indicating lower test reliability.
- 15 October 2025
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 9 (2) , 176-184
Comparison of the Variational Bayes Linear Regression Visual Field Test Algorithms and the Swedish Interactive Threshold Algorithm Standard in the 10-2 Program
- 15 October 2025
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 9 (2) , 176-184
Comparison of the Variational Bayes Linear Regression Visual Field Test Algorithms and the Swedish Interactive Threshold Algorithm Standard in the 10-2 Program
- 21 June 2025
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 69 (6) , 955-964
Development of a reliability criterion for the binocular Esterman visual field test
Purpose To evaluate the repeatability of the binocular Esterman visual field (bEVF) test and develop a corresponding reliability criterion based on repeatability-associated factors. Study design Prospective cross-sectional study. Methods Ninety-five glaucoma patients underwent two bEVF tests on the same day using a Humphrey field analyzer. The repeatability of the bEVF was assessed by the agreement rate for seen and unseen points over all test points between the first and second tests. Factors associated with the repeatability were analyzed with multivariate linear regression analysis. Receiver operating characteristic (ROC) curve analysis was performed for those associated factors to identify the reliability criterion. Results The mean agreement rate was 88.9% (95% confidence interval [CI]: 73.9%, 99.2%). A total of 44 patients (46.3%), 75 patients (78.9%), and 88 patients (92.6%) had agreement rates of more than 90%, 85%, and 80%, respectively. The false positive (FP) response rate of the bEVF test was negatively associated with the agreement rate (p7.1% (sensitivity = 71.0% and specificity = 88.0%), while the cutoff value based on a fixed 95% specificity was >12.1% (sensitivity = 28.6%). Conclusion An approximately 90% agreement rate existed for the bEVF test when applied to glaucoma patients. The FP response rate was associated with the repeatability of the bEVF test, and 8% or at least 13% may serve as a useful reference to ensure an agreement rate of 80% or higher.
- 21 June 2025
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 69 (6) , 955-964
Development of a reliability criterion for the binocular Esterman visual field test
Purpose To evaluate the repeatability of the binocular Esterman visual field (bEVF) test and develop a corresponding reliability criterion based on repeatability-associated factors. Study design Prospective cross-sectional study. Methods Ninety-five glaucoma patients underwent two bEVF tests on the same day using a Humphrey field analyzer. The repeatability of the bEVF was assessed by the agreement rate for seen and unseen points over all test points between the first and second tests. Factors associated with the repeatability were analyzed with multivariate linear regression analysis. Receiver operating characteristic (ROC) curve analysis was performed for those associated factors to identify the reliability criterion. Results The mean agreement rate was 88.9% (95% confidence interval [CI]: 73.9%, 99.2%). A total of 44 patients (46.3%), 75 patients (78.9%), and 88 patients (92.6%) had agreement rates of more than 90%, 85%, and 80%, respectively. The false positive (FP) response rate of the bEVF test was negatively associated with the agreement rate (p7.1% (sensitivity = 71.0% and specificity = 88.0%), while the cutoff value based on a fixed 95% specificity was >12.1% (sensitivity = 28.6%). Conclusion An approximately 90% agreement rate existed for the bEVF test when applied to glaucoma patients. The FP response rate was associated with the repeatability of the bEVF test, and 8% or at least 13% may serve as a useful reference to ensure an agreement rate of 80% or higher.
- Open Access
- 3 April 2023
- Published by BMJ in BMJ Open Ophthalmology
- Vol. 8 (1) , e001256
Degree of loss in the tissue thickness, microvascular density, specific perimetry and standard perimetry in early glaucoma
Objective To identify the degree of loss of the circumpapillary retinal nerve fibre layer (cpRNFL), the layer from the macular RNFL to the inner plexiform layer (mGCL++), circumpapillary (cpVD) and macular vascular density (mVD), Pulsar perimetry and standard perimetry in early glaucoma. Methods In this cross-sectional study, one eye from each of 96 healthy controls and 90 eyes with open-angle glaucoma were measured with cpRNFL, mGCL++, cpVD, mVD, Pulsar perimetry with Octopus P32 test (Pulsar) and standard perimetry with Humphrey field analyser 24-2 test (HFA). For direct comparison, all parameters were converted to relative change values adjusted in both their dynamic range and age-corrected normal value. Results The degree of loss in mGCL++ (−24.7%) and cpRNFL (−25.8%) was greater than that in mVD (−17.3%), cpVD (−14.9%), Pulsar (−10.1%) and HFA (−5.9%) (each pConclusion The degree of loss of cpRNFL and mGCL++ thickness preceded by approximately 7%–10% and 15%–20% compared with the micro-VD and visual fields in early glaucoma, respectively. Trial registration number UMIN Clinical Trials Registry (http://www.umin.ac.jp/; R000046076 UMIN000040372).
- 3 April 2023
- Published by BMJ in BMJ Open Ophthalmology
- Vol. 8 (1) , e001256
Open AccessDegree of loss in the tissue thickness, microvascular density, specific perimetry and standard perimetry in early glaucoma
Objective To identify the degree of loss of the circumpapillary retinal nerve fibre layer (cpRNFL), the layer from the macular RNFL to the inner plexiform layer (mGCL++), circumpapillary (cpVD) and macular vascular density (mVD), Pulsar perimetry and standard perimetry in early glaucoma. Methods In this cross-sectional study, one eye from each of 96 healthy controls and 90 eyes with open-angle glaucoma were measured with cpRNFL, mGCL++, cpVD, mVD, Pulsar perimetry with Octopus P32 test (Pulsar) and standard perimetry with Humphrey field analyser 24-2 test (HFA). For direct comparison, all parameters were converted to relative change values adjusted in both their dynamic range and age-corrected normal value. Results The degree of loss in mGCL++ (−24.7%) and cpRNFL (−25.8%) was greater than that in mVD (−17.3%), cpVD (−14.9%), Pulsar (−10.1%) and HFA (−5.9%) (each pConclusion The degree of loss of cpRNFL and mGCL++ thickness preceded by approximately 7%–10% and 15%–20% compared with the micro-VD and visual fields in early glaucoma, respectively. Trial registration number UMIN Clinical Trials Registry (http://www.umin.ac.jp/; R000046076 UMIN000040372).
- 19 October 2022
- Published by BMJ in British Journal of Ophthalmology
- Vol. 108 (1) , 78-83
Accuracy of pattern deviation in estimating the glaucomatous damage in the central 10° visual field in eyes with glaucoma and cataract
Background/aims: The accuracy of pattern deviation (PD) in estimating the damage to the glaucomatous visual field (VF) in the central 10° in eyes with glaucoma and cataract is unclear. Methods: This retrospective study includes 63 eyes of 52 glaucoma patients who successfully underwent cataract surgery or cataract surgery plus iStent implantation. Using the Humphrey Field Analyser 10–2 test, VF was measured within 6 months preoperatively and postoperatively (VF pre and VF post , respectively). The mean total deviation values in VF post (mTD post ) indicates glaucomatous damage without cataract and the difference between this value and mean PD values in VF pre (mPD pre ) was evaluated (εmPD). The effect of cataract was then evaluated as the difference between mTD post and mTD pre (ΔmTD), while the effects of mTD post and ΔmTD on εmPD were also assessed. In addition, based on preoperative visual acuity (VA pre ) and VF pre , the optimal model for predicting mTD post was identified. The error of this method (εOptimalModel) was estimated as the difference against mTD post , which was compared with εmPD. Results: Compared with mTD pre , there was a significant improvement in mTD post (p=0.028). A significant difference was observed between mPD pre and mTD post (ppost or ΔmTD (p<0.001 and p=0.0444, respectively). The absolute εOptimalModel was significantly smaller than the absolute εmPD (p<0.001). Conclusions: This study warns clinicians that PD of the central 10° VF might underestimate the glaucomatous VF damage with the progression of glaucoma and overestimate it as a cataract progresses.
- 19 October 2022
- Published by BMJ in British Journal of Ophthalmology
- Vol. 108 (1) , 78-83
Accuracy of pattern deviation in estimating the glaucomatous damage in the central 10° visual field in eyes with glaucoma and cataract
Background/aims: The accuracy of pattern deviation (PD) in estimating the damage to the glaucomatous visual field (VF) in the central 10° in eyes with glaucoma and cataract is unclear. Methods: This retrospective study includes 63 eyes of 52 glaucoma patients who successfully underwent cataract surgery or cataract surgery plus iStent implantation. Using the Humphrey Field Analyser 10–2 test, VF was measured within 6 months preoperatively and postoperatively (VF pre and VF post , respectively). The mean total deviation values in VF post (mTD post ) indicates glaucomatous damage without cataract and the difference between this value and mean PD values in VF pre (mPD pre ) was evaluated (εmPD). The effect of cataract was then evaluated as the difference between mTD post and mTD pre (ΔmTD), while the effects of mTD post and ΔmTD on εmPD were also assessed. In addition, based on preoperative visual acuity (VA pre ) and VF pre , the optimal model for predicting mTD post was identified. The error of this method (εOptimalModel) was estimated as the difference against mTD post , which was compared with εmPD. Results: Compared with mTD pre , there was a significant improvement in mTD post (p=0.028). A significant difference was observed between mPD pre and mTD post (ppost or ΔmTD (p<0.001 and p=0.0444, respectively). The absolute εOptimalModel was significantly smaller than the absolute εmPD (p<0.001). Conclusions: This study warns clinicians that PD of the central 10° VF might underestimate the glaucomatous VF damage with the progression of glaucoma and overestimate it as a cataract progresses.
- 1 March 2022
- Published by BMJ in British Journal of Ophthalmology
- Vol. 107 (7) , 946-952
Faster algorithms to measure visual field using the variational Bayes linear regression model in glaucoma: comparison with SITA-Fast
Aims To compare the visual field (VF) test results measured with the Swedish Interactive Threshold Algorithm Fast (SITA-Fast) and newly developed variational Bayes linear regression visual field (VBLR-VF) Fast or VBLR-VF Fast+. Method Of 65 patients with glaucoma, 31 eyes of 31 patients performed VBLR-VF Fast and SITA-Fast, and 34 eyes of 34 patients performed VBLR-VF Fast+ and SITA-Fast on the same day and iterated the same procedures within 6 months using the 24–2 test grid in the current prospective study. Global index (mean deviation and pattern SD), pointwise retinal sensitivity, test duration and reliability index (fixation loss, false positive and false negative) were compared between SITA-Fast and VBLR-VF Fast or VBLR-VF Fast+. Results Global indices were not significantly different between SITA-Fast and VBLR-VF Fast or VBLR-VF Fast+. There was no significant difference in the pointwise retinal sensitivity between the SITA-Fast and VBLR-VF Fast algorithms at the first visit, while the VBLR-VF Fast algorithm was approximately 1 dB higher compared to the SITA-Fast algorithm at the second visit. Test duration was reduced by approximately 30 s (10%) with VBLR-VF Fast and by approximately 80 s (30%) with VBLR-VF Fast+ compared with to SITA-Fast (pConclusion Both VBLR-VF Fast and VBLR-VF Fast+ considerably reduced the test durations. Although there was a marginal difference in the pointwise retinal sensitivities, global indices were almost interchangeable between the VBLR-VF Fast and SITA-Fast.
- 1 March 2022
- Published by BMJ in British Journal of Ophthalmology
- Vol. 107 (7) , 946-952
Faster algorithms to measure visual field using the variational Bayes linear regression model in glaucoma: comparison with SITA-Fast
Aims To compare the visual field (VF) test results measured with the Swedish Interactive Threshold Algorithm Fast (SITA-Fast) and newly developed variational Bayes linear regression visual field (VBLR-VF) Fast or VBLR-VF Fast+. Method Of 65 patients with glaucoma, 31 eyes of 31 patients performed VBLR-VF Fast and SITA-Fast, and 34 eyes of 34 patients performed VBLR-VF Fast+ and SITA-Fast on the same day and iterated the same procedures within 6 months using the 24–2 test grid in the current prospective study. Global index (mean deviation and pattern SD), pointwise retinal sensitivity, test duration and reliability index (fixation loss, false positive and false negative) were compared between SITA-Fast and VBLR-VF Fast or VBLR-VF Fast+. Results Global indices were not significantly different between SITA-Fast and VBLR-VF Fast or VBLR-VF Fast+. There was no significant difference in the pointwise retinal sensitivity between the SITA-Fast and VBLR-VF Fast algorithms at the first visit, while the VBLR-VF Fast algorithm was approximately 1 dB higher compared to the SITA-Fast algorithm at the second visit. Test duration was reduced by approximately 30 s (10%) with VBLR-VF Fast and by approximately 80 s (30%) with VBLR-VF Fast+ compared with to SITA-Fast (pConclusion Both VBLR-VF Fast and VBLR-VF Fast+ considerably reduced the test durations. Although there was a marginal difference in the pointwise retinal sensitivities, global indices were almost interchangeable between the VBLR-VF Fast and SITA-Fast.
- Open Access
- 30 January 2022
- Published by Elsevier in Ophthalmology Science
- Vol. 2 (2) , 100120
Structure–Function Relationships and Glaucoma Detection with Magnification Correction of OCT Angiography
- 30 January 2022
- Published by Elsevier in Ophthalmology Science
- Vol. 2 (2) , 100120
Open AccessStructure–Function Relationships and Glaucoma Detection with Magnification Correction of OCT Angiography
- Open Access
- 13 January 2021
- Published by BMJ in British Journal of Ophthalmology
- Vol. 106 (5) , 660-666
Comparing the usefulness of a new algorithm to measure visual field using the variational Bayes linear regression in glaucoma patients, in comparison to the Swedish interactive thresholding algorithm
Background/aims We previously reported that the visual field (VF) prediction model using the variational Bayes linear regression (VBLR) is useful for accurately predicting VF progression in glaucoma (Invest Ophthalmol Vis Sci. 2014, 2018). We constructed a VF measurement algorithm using VBLR, and the purpose of this study was to investigate its usefulness. Method 122 eyes of 73 patients with open-angle glaucoma were included in the current study. VF measurement was performed using the currently proposed VBLR programme with AP-7700 perimetry (KOWA). VF measurements were also conducted using the Swedish interactive thresholding algorithm (SITA) standard programme with Humphrey field analyser. VF measurements were performed using the 24–2 test grid. Visual sensitivities, test–retest reproducibility and measurement duration were compared between the two algorithms. Result Mean mean deviation (MD) values with SITA standard were −7.9 and −8.7 dB (first and second measurements), whereas those with VBLR-VF were −8.2 and −8.0 dB, respectively. There were no significant differences across these values. The correlation coefficient of MD values between the 2 algorithms was 0.97 or 0.98. Test–retest reproducibility did not differ between the two algorithms. Mean measurement duration with SITA standard was 6 min and 02 s or 6 min and 00 s (first or second measurement), whereas a significantly shorter duration was associated with VBLR-VF (5 min and 23 s or 5 min and 30 s). Conclusion VBLR-VF reduced test duration while maintaining the same accuracy as the SITA-standard.
- 13 January 2021
- Published by BMJ in British Journal of Ophthalmology
- Vol. 106 (5) , 660-666
Open AccessComparing the usefulness of a new algorithm to measure visual field using the variational Bayes linear regression in glaucoma patients, in comparison to the Swedish interactive thresholding algorithm
Background/aims We previously reported that the visual field (VF) prediction model using the variational Bayes linear regression (VBLR) is useful for accurately predicting VF progression in glaucoma (Invest Ophthalmol Vis Sci. 2014, 2018). We constructed a VF measurement algorithm using VBLR, and the purpose of this study was to investigate its usefulness. Method 122 eyes of 73 patients with open-angle glaucoma were included in the current study. VF measurement was performed using the currently proposed VBLR programme with AP-7700 perimetry (KOWA). VF measurements were also conducted using the Swedish interactive thresholding algorithm (SITA) standard programme with Humphrey field analyser. VF measurements were performed using the 24–2 test grid. Visual sensitivities, test–retest reproducibility and measurement duration were compared between the two algorithms. Result Mean mean deviation (MD) values with SITA standard were −7.9 and −8.7 dB (first and second measurements), whereas those with VBLR-VF were −8.2 and −8.0 dB, respectively. There were no significant differences across these values. The correlation coefficient of MD values between the 2 algorithms was 0.97 or 0.98. Test–retest reproducibility did not differ between the two algorithms. Mean measurement duration with SITA standard was 6 min and 02 s or 6 min and 00 s (first or second measurement), whereas a significantly shorter duration was associated with VBLR-VF (5 min and 23 s or 5 min and 30 s). Conclusion VBLR-VF reduced test duration while maintaining the same accuracy as the SITA-standard.
- 28 August 2020
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 258 (11) , 2467-2476
Long-term clinical results of trabectome surgery in patients with open-angle glaucoma
Purpose To evaluate the 72-month clinical results of trabectome surgery (TOM) in patients with primary open-angle glaucoma (POAG), secondary OAG and childhood glaucoma. Method A total of 305 eyes from 249 glaucoma patients were analyzed in the current retrospective single-center study. Kaplan-Meier analysis was performed using three criteria: criterion A (postoperative intraocular pressure [IOP] ≤ 21 mmHg and ≥ 20% reduction from baseline IOP); criterion B (postoperative IOP ≤ 18 mmHg and ≥ 20% reduction from baseline IOP); and criterion C (postoperative IOP ≤ 16 mmHg and ≥ 20% reduction from baseline IOP). The changes in IOP, medication score, success probability, results of the multivariate analysis for success and failure risk factors, and complications were analyzed. Results The baseline IOP in all glaucoma patients decreased from 29.2 ± 9.8 mmHg with a 5.3 ± 1.7 medication score to 16.4 ± 5.8 mmHg (− 43.8%) with a 4.2 ± 1.5 medication score at 72 months (p < 0.01). The success probabilities in all cases for 72 months based on criterion A, B, and C were 44%, 35%, and 17%, respectively. For criterion A, no significant differences were found in the success probability according to the glaucoma subtype for 72 months. The combined surgical procedure significantly decreased the failure risk (hazard ratio [HR]: 0.59). On the other hand, the presence of POAG (HR: 1.6) and a history of past selective laser trabeculoplasty (HR: 2.2) significantly increased failure risk. One patient (0.3%) demonstrated endophthalmitis after TOM but recovered through appropriate treatment. Conclusion At the 72-month time point, approximately half of the glaucoma patients maintained an IOP ≤ 21 mmHg with ≥ 20% IOP reduction. TOM is a safe surgery but may not yield sufficient IOP reduction in patients who have received SLT or have POAG.
- 28 August 2020
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 258 (11) , 2467-2476
Long-term clinical results of trabectome surgery in patients with open-angle glaucoma
Purpose To evaluate the 72-month clinical results of trabectome surgery (TOM) in patients with primary open-angle glaucoma (POAG), secondary OAG and childhood glaucoma. Method A total of 305 eyes from 249 glaucoma patients were analyzed in the current retrospective single-center study. Kaplan-Meier analysis was performed using three criteria: criterion A (postoperative intraocular pressure [IOP] ≤ 21 mmHg and ≥ 20% reduction from baseline IOP); criterion B (postoperative IOP ≤ 18 mmHg and ≥ 20% reduction from baseline IOP); and criterion C (postoperative IOP ≤ 16 mmHg and ≥ 20% reduction from baseline IOP). The changes in IOP, medication score, success probability, results of the multivariate analysis for success and failure risk factors, and complications were analyzed. Results The baseline IOP in all glaucoma patients decreased from 29.2 ± 9.8 mmHg with a 5.3 ± 1.7 medication score to 16.4 ± 5.8 mmHg (− 43.8%) with a 4.2 ± 1.5 medication score at 72 months (p < 0.01). The success probabilities in all cases for 72 months based on criterion A, B, and C were 44%, 35%, and 17%, respectively. For criterion A, no significant differences were found in the success probability according to the glaucoma subtype for 72 months. The combined surgical procedure significantly decreased the failure risk (hazard ratio [HR]: 0.59). On the other hand, the presence of POAG (HR: 1.6) and a history of past selective laser trabeculoplasty (HR: 2.2) significantly increased failure risk. One patient (0.3%) demonstrated endophthalmitis after TOM but recovered through appropriate treatment. Conclusion At the 72-month time point, approximately half of the glaucoma patients maintained an IOP ≤ 21 mmHg with ≥ 20% IOP reduction. TOM is a safe surgery but may not yield sufficient IOP reduction in patients who have received SLT or have POAG.