Dose comparison between screen/film and full-field digital mammography
Authors:
- 30 May 2006
- journal article
- Published by Springer Nature in European Radiology
- Vol. 16 (11) , 2559-2566
Abstract
The study purpose was the comparison between doses delivered by a full-field digital mammography system and a screen/film mammography unit, both using the same type of X-ray tube. Exposure parameters and breast thickness were collected for 300 screen/film (GE Senographe DMR) and 296 digital mammograms (GE Senographe 2000D). The entrance surface air kerma (ESAK) was calculated from anode/filter combination, kVp and mAs values and breast thickness, by simulating spectra through a program based on a catalogue of experimental X-ray spectra. The average glandular dose (AGD) was also computed. Results showed an overall reduction of average glandular dose by 27% of digital over screen/film mammography. The dose saving was about 15% for thin and thick breasts, while it was between 30% and 40% for intermediate thicknesses. Full-field digital mammography dose reduction is allowed by wider dynamic range and higher efficiency of digital detector, which can be exposed at higher energy spectra than screen/film mammography, and by the separation between acquisition and displaying processes.Keywords
This publication has 46 references indexed in Scilit:
- Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer ScreeningNew England Journal of Medicine, 2005
- Dose to population as a metric in the design of optimised exposure control in digital mammographyRadiation Protection Dosimetry, 2005
- Diagnostic accuracy of Fischer Senoscan Digital Mammography versus screen-film mammography in a diagnostic mammography population1Academic Radiology, 2004
- Patient dose in full-field digital mammography: an Italian surveyEuropean Radiology, 2004
- Dose reduction in full-field digital mammography: an anthropomorphic breast phantom studyBritish Journal of Radiology, 2003
- Breast Doses from Patients and from Standard Phantom: Analysis of DifferencesRadiation Protection Dosimetry, 2000
- Mammography Radiation Dose and Image QualityRadiation Protection Dosimetry, 1998
- Determination of average glandular dose with modern mammography units for two large groups of patientsPhysics in Medicine & Biology, 1997
- X-ray imaging with amorphous selenium: Optimal spectra for digital mammographyMedical Physics, 1996
- Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detectorPhysics in Medicine & Biology, 1979