Implantation of integrated magnetically levitated biventricular assist devices (DuoCor) – a single-center clinical experience
Open Access
- 23 July 2025
- journal article
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 111 (10) , 6743-6754
Abstract
Background: End-stage heart failure remains a major global health challenge with high mortality. While heart transplantation is the gold-standard treatment, the scarcity of donor hearts necessitates alternative therapies. Left ventricular assist devices effectively support patients with end-stage left heart failure, but no mature biventricular assist devices (BiVADs) currently exist for those with biventricular failure. To address this gap, we developed the DuoCor BiVAD, a novel, integrated, magnetically levitated miniaturized biventricular assist system. Methods: This study reports the results of animal experiments and short-term clinical outcomes focusing on the DuoCor BiVAD. Animal experiments were conducted on three healthy adult male Chinese Merino sheep, with the endpoint being 2 months after device implantation, followed by retrieval and evaluation. Clinical data were collected from eight patients who underwent DuoCor BiVAD implantation at Wuhan Union Hospital between July 2024 and December 2024, with a median follow-up period of 6 months. During this period, device parameters, changes in patient heart function, and the occurrence of device-related adverse events (such as infection, thrombosis, and bleeding) were monitored. Results: All animal implants achieved technical success (4.0 ± 0.7 h procedure time) with sustained 60-day hemodynamic stability and absence of device malfunction, thrombosis, or infection. In the clinical study, the median operative time was 5.1 hours, and the median postoperative hospital stay was 35 days. There were no in-hospital mortalities or device-related infections, and all patients were discharged home with DuoCor BiVAD support. During the 6-month postoperative follow-up period, one 81-year-old patient succumbed to frailty and COVID-19 infection 2 weeks post-discharge. The remaining seven patients survived with ongoing DuoCor BiVAD support, with no incidents of hemolysis, bleeding, device-related infection, or chronic renal insufficiency. This cohort includes one patient who developed right ventricular assist device thrombosis at 2 months post-implantation. Evaluation confirmed recovery of right ventricular function after the acute postoperative phase, prompting the discontinuation of right pump support. This patient subsequently maintained hemodynamic stability with left ventricular assist device support and experienced no further adverse events throughout follow-up. Conclusion: As a feasibility validation study of the first artificial BiVAD, DuoCor BiVAD demonstrated acceptable safety profiles during the short-term observation period. Although preliminary clinical outcomes were promising, these findings warrant cautious interpretation due to study size limitations and restricted follow-up duration. Furthermore, the device’s integrated lightweight design and differential ventricular support technology confer advantages over existing solutions. Further validation through prospective multicenter cohort studies remains essential to establish long-term safety and efficacy profiles.Keywords
This publication has 40 references indexed in Scilit:
- 2019 EACTS Expert Consensus on long-term mechanical circulatory supportEuropean Journal of Cardio-Thoracic Surgery, 2019
- An international multicenter experience of biventricular support with HeartMate 3 ventricular assist systemsThe Journal of Heart and Lung Transplantation, 2018
- Multicenter experience with durable biventricular assist devicesThe Journal of Heart and Lung Transplantation, 2018
- Long-Term Evaluation of a Fully Magnetically Levitated Circulatory Support Device for Advanced Heart Failure—Two-Year Results from The Heartmate 3 CE Mark StudyEuropean Journal of Heart Failure, 2018
- Long-term biventricular HeartWare ventricular assist device support—Case series of right atrial and right ventricular implantation outcomesThe Journal of Heart and Lung Transplantation, 2016
- Biventricular Circulatory Support With Two Miniaturized Implantable Assist DevicesCirculation, 2011
- Long-term biventricular support with the heartware implantable continuous flow pumpThe Journal of Heart and Lung Transplantation, 2010
- Improving Bioscience Research Reporting: The ARRIVE Guidelines for Reporting Animal ResearchPLOS Biology, 2010
- Vasoplegia During Cardiac Surgery: Current Concepts and ManagementSeminars in Thoracic and Cardiovascular Surgery, 2010
- Continuous Subcutaneous Infusion of Treprostinil, a Prostacyclin Analogue, in Patients with Pulmonary Arterial Hypertension: A Double-blind, Randomized, Placebo-controlled TrialAmerican Journal of Respiratory and Critical Care Medicine, 2002