Temperature Peak-Drift Correction Method for NaI(Tl) Detectors Using the Background Peak
Open Access
Abstract
The overall gain of a scintillation detector is temperature-dependent, leading to a drift in the measured gamma energy spectrum with changes in temperature. To mitigate this effect, a temperature drift correction is essential prior to conducting gamma spectrum analysis. In this study, the detector gain ratio is determined by comparing the positions of the same background peak across different spectra. Subsequently, the original spectrum is adjusted accordingly to obtain a gamma spectrum free from temperature drift. Experimental results demonstrate that after implementing this correction, the relative deviation of the 57Co characteristic peak positions in the gamma spectrum measured by the NaI(Tl) detector is reduced from 18.64% to 0.91%. Furthermore, by performing energy calibration beforehand, the characteristic peak position can be utilized for secondary correction, further minimizing temperature drift. Our findings indicate that the relative deviation of the 22Na characteristic peak positions was reduced, respectively, to 0.51% and 0.46% through secondary correction. This approach, which utilizes the background peak for correction, avoids the need for additional radioactivity or circuitry and effectively mitigates peak drift. Overall, this method holds significant implications for enhancing the accuracy of gamma spectrum analysis.Keywords
This publication has 20 references indexed in Scilit:
- A new method for correction of temperature changes in scintillation detector without using a radioactive sourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2022
- An automated drift correction method for in situ NaI(Tl)-detectors used in extreme environmentsApplied Radiation and Isotopes, 2022
- A new numerical correction method for gamma spectra based on the system transformation theory of random signalsApplied Radiation and Isotopes, 2021
- GAMMA SPECTRUM STABILIZATION FOR ENVIRONMENTAL RADIATION MONITORING STATIONS USING NAI(TL) DETECTORRadiation Protection Dosimetry, 2020
- Temperature peak-shift correction methods for NaI(Tl) and LaBr3(Ce) gamma-ray spectrum stabilisationRadiation Measurements, 2012
- Temperature behavior of NaI(Tl) scintillation detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Temperature dependence of nonlinearity and pulse shape in a doped NaI(Tl) scintillatorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Temperature dependences of LaBr3(Ce), LaCl3(Ce) and NaI(Tl) scintillatorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- Inorganic scintillation detectors in γ-ray spectrometryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Gamma-ray spectrometry in the environmentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996